FerraraFixed guide rail lifting cargo elevatorSeveral factors affecting poor quality

announcer:hp779HP136589660 release time:2023-12-17 12:38:21

When a cargo elevator fails, it should be repaired by professional personnel. It is not allowed to modify the cargo elevator without permission.

In addition, clean the anti rust oil on the motor input shaft, positioning boss and elevator connection parts with gasoline or zinc sodium water. Its purpose is to ensure the tightness of the connection and the flexibility of operation, and to prevent unnecessary wear and tear.

Ferrara.Overview of manual hydraulic platform: Manual hydraulic platform is a small lifting mechanical platform, mainly used for small range lifting, lifting, moving, and placing of items, as well as handling small valuable items. The product has a generous and beautiful appearance, solid structure, stability, safety and reliability, and its performance and service life have reached the advanced level of the same equipment. Currently, the mainstream of the market is hydraulic driven lifting. Due to its compact size and convenient mobility, it is widely used in logistics and transportation, warehouse management, libraries, supermarkets, and ordinary small equipment manufacturing industries.

Outriggers: mechanical outriggers, hydraulic outriggers, ordinary hand cranking outriggers, and pull-out outriggers.

.Hydraulic lifting platforms are widely used in factory maintenance, municipal construction, and decoration of hotels in industrial and mining enterprises, with reliable quality and perfect performance.

Motor connection error. When the triangular connection motor is mistakenly connected into a star shape, the motor still operates with full load, and the current flowing through the stator winding exceeds the rated current, leading to the motor stopping itself. If the stopping time is slightly longer and the power supply is not cut off, the winding will not only be severely overheated, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch, the motor is mistakenly connected into two branches in parallel, both the windings and the iron core will overheat, and in severe cases the windings will be burned.

The common types of elevators will be briefly introduced here. I hope you can have a better understanding of this product. Currently, this product can be said to be sold well in China, because many places need to use this kind of product with lifting function and flexible movement. Now, companies specializing in producing this type of product combine with extensive external publicity on the Internet, Friends in need can directly find the corresponding company on the Internet, and then have a brief understanding of the model, performance, and price information of these products. They can purchase directly through the Internet.


FerraraFixed guide rail lifting cargo elevatorSeveral factors affecting poor quality



Regardless of whether it is used outdoors or indoors, it is inevitable that some small problems will occur after a long period of time. At this time, what we should do is to maintain and maintain the elevator. How to follow the steps correctly becomes a difficult problem. Let me explain it to you.

It is strictly prohibited to connect the motor of the lifting platform to the wrong power supply. It should be ensured that the voltage is 380v or 220v, and daily cleaning work should be carried out. Dust and debris on the motor should be cleaned in a timely manner.

Guide rail elevator (also known as cargo elevator) is a non scissor fork type hydraulic lifting platform, mainly used in industrial buildings restaurants, restaurants, warehouses, docks, workshops, and other places where vertical cargo handling is required between two or more floors. The low height is particularly suitable for sites that are not suitable for digging pits on site. What issues should we pay attention to in these places where elevators are used?

Inspection basis.Is the water cooling and air cooling of the hydraulic station the same?

Many people believe that the mechanical strength of the elevator itself is relatively high when using the elevator so the installation method specified in the manual is not strictly followed during the installation process. However,FerraraWhere is there a lift for goods, this can lead to increased wear of parts and inflexibility in operation. In addition,FerraraTwo layers of hydraulic lifting cargo elevator, it is necessary to pay attention to the installation precautions corresponding to the working environment and not be careless. Correct installation, use, and maintenance of the elevator are important steps to ensure the normal operation of mechanical equipment. Therefore, when installing the elevator, install a separate distribution box. When using the distribution box, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.


FerraraFixed guide rail lifting cargo elevatorSeveral factors affecting poor quality



Does the cleanliness of the hydraulic station have relevant rules and requirements?

Customer first.Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that, remove the motor shaft key.

As we all know now, elevators and lifting platforms have been widely used in recent years to solve the problems we encounter in daily life. Because working at heights is a high-risk profession that requires the assistance of auxiliary tools to complete certain tasks, the use of elevators is undoubtedly emerging in the domestic machinery market and has been vigorously developed.

Motor connection error. When the triangular connection motor is mistakenly connected into a star shape, the motor still operates with full load, leading to the motor stopping itself. If the stopping time is slightly longer and the power supply is not cut off, the winding will not only be severely overheated, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch, the motor is mistakenly connected into two branches in parallel, both the windings and the iron core will overheat,Ferrara1 ton lifting cargo elevator, and in severe cases, the windings will be burned.

Ferrara.Low cost: Compared to the scissor type mobile lifting platform, the cost is much lower. Therefore when purchasing a lifting platform, it is necessary to consider the use range, frequency of work, load, and other factors of the lifting platform to select a lifting platform suitable for the work requirements.

Several types: motor winding open circuit. When one phase of the motor winding is open circuit, it will cause three-phase current imbalance and cause the motor to overheat.

Several types: motor winding open circuit. When one phase of the motor winding is open circuit, or one of the parallel branches is open circuit