MadisonWarehouse elevatorCity application analysis

announcer:hp779HP136589660 release time:2024-05-30 09:23:36

Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes, with a scissors type mechanical mechanism, easy to maintain, strong stability,MadisonHydraulic lifting cargo elevator, and high bearing capacity. The lifting height is about 10 meters, and the load capacity is about 10 tons.

Systems: explosion-proof electronic control system, PIC system.

Madison.Purpose of manual hydraulic platform: The manual hydraulic transportation platform has novel design, reasonable structure, and convenient use. Suitable for loading, unloading, transporting, workshops, warehouses and oil depots. It is particularly suitable for use in chemical and food workshops as a dumping or batching machine. It can also be used to load and unload heavy objects on trucks, stack them, confirm whether the motor and the elevator are intact and strictly check whether the dimensions of each part connecting the motor and the elevator match. Here are the dimensions and fit tolerances of the positioning boss, and elevator groove of the motor.

.The hydraulic lifting platform mainly uses hydraulic oil pressure transmission to achieve the lifting function. Its shear fork mechanical structure provides stability for the lift. The wide working platform and high bearing capacity make the high-altitude operation range wide and suitable for multiple people to work simultaneously. It makes aerial work efficient and guaranteed.

Usage: Scissor fork type fixed lifting platforms are mostly used for goods transportation between height differences in production lines input shaft, loading and unloading materials, adjusting the working height during workpiece assembly, feeding materials to loading machines at high altitudes, lifting components during assembly of large equipment, vehicle lifting, fixed three-dimensional parking, and other places.

The water cooling of hydraulic stations is generally tubular water cooling, and the type selection is based on the heat load to calculate the heat exchange area, while the air-cooled elevator is conducted using an air cooler, and the heat exchange capacity is calculated based on the heat load. Then, the type selection calculation is performed when the flow can be satisfied. Therefore, the two types of cooling are different, and there are significant differences. Long-term lifting and lowering of cargo elevator factory


MadisonWarehouse elevatorCity application analysis



Connect the motor to the elevator naturally. During connection, and that the outer flanges of the two are parallel. Inconsistent centering can cause the motor shaft to break or the elevator gear to wear.

Before using the machine,MadisonElevating cargo elevator, pay attention to alignment, leveling, and alignment, and ensure the level of the foundation and various usage requirements.

Quality Assurance.Before installing the elevator, confirm whether the motor and the elevator are intact, and strictly check whether the dimensions of each part connecting the motor and the elevator match. Here are the dimensions and fit tolerances of the positioning boss, input shaft, and elevator groove of the motor.

The elevator is a kind of elevator equipment composed of a walking mechanism, a hydraulic mechanism, an electric mechanism, and a support mechanism. The hydraulic oil forms a certain pressure by a vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, flameproof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve. This allows the hydraulic cylinder to move upward and lift heavy objects. The return oil from the upper end of the hydraulic cylinder returns to the tank through the flameproof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. Observe the reading value of the pressure gauge on the pressure gauge.

Secondly, there should be no dirt on the friction surface. If there is any dirt, it should be washed off with gasoline or thinner; The reduction gearbox, gearbox, external meshing gear, and other parts of the equipment, as well as the hydraulic oil, must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found, replace it in a timely manner. The maintenance of the wire ropes must be carried out in strict accordance with the specifications; Check the connection condition of each part according to the braking rules and regulations. If there is any looseness, tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, whether there are noises and faults according to regulations, and adjusting the rotating mechanism of the equipment disassembling, it is important to note that the reducer and the gear center line should be parallel, and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables,MadisonElevating cargo elevators from first to second floors, and if there is overheating of the motor. Replace the motor in a timely manner and eliminate the fault before continuing operation; Ensure that the bearings boxes, distribution boxes, and brushes of the motor are kept clean, and that the travel switch points of each safety device must be safe and reliable.


MadisonWarehouse elevatorCity application analysis



Before installing the elevator confirm whether the motor and the elevator are intact, and strictly check whether the dimensions of each part connecting the motor and the elevator match. Here are the dimensions and fit tolerances of the positioning boss, input shaft, and elevator groove of the motor.

Welcome to inquire.The motor winding is short-circuited. When a short circuit fault occurs in the motor winding, the short circuit current is much larger than the normal working current, which increases the copper loss of the winding, causing the winding to overheat or even burn out.

The guide mechanism of the guide mechanism of the guide rail elevator manufacturer is mainly composed of guide plastic pipes, guide brackets, compression springs, safety plugs, guide housings, and guide shafts. As a semi sectional view of the guide mechanism, a narrow gap is formed between the two guide plastic pipes, and the lifting cloth belt extends out of the box from this narrow gap to prevent the cloth belt from being tangled and serve as a guide. The safety plug is supported by a guide bracket and a compression spring. In order to prevent the compression spring from losing stability after being stressed, a small guide rod is designed on the safety plug, and the gap between the small guide rod and the spring is designed according to the table. The crane arm shaft is welded and installed with a crane arm hook at both ends. The material is selected and subjected to conditioning treatment. It forms three suspension points with the hook at the lower shell of the box. The soft support sling will be lifted by the person being lifted. The load bearing capacity of the crane arm is designed to ensure that the person being lifted can be in a comfortable state when riding. The distance between the two crane arm hooks is listed in the table as a design reference, and the balance bar is used to maintain the balance of the lifting device, The material is designed as a hollow tube, reducing the overall weight of the boom.

Characteristics of hydraulic elevators: Hydraulic lifting platform products are divided into curved arm type hydraulic lifting machines, scissors type hydraulic lifting machines, mast type hydraulic lifts, and straight arm type hydraulic lifts according to their working modes. Hydraulic elevator is a replacement product of folding arm elevator (lifting platform) and scissor fork elevator (lifting platform). It can be widely used for the decoration and decoration of stations, docks, airports, hotels, posts and telecommunications, municipal gardens, garages, cleaning companies, public building facades, or the installation and maintenance of power systems, etc. This elevator has the advantages of light weight, self-propelled walking, electric starting, self supporting legs, simple operation, large working area, and especially the ability to cross obstacles for aerial work.

Madison.Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes, with a scissors type mechanical mechanism, easy to maintain, strong stability, and high bearing capacity. The lifting height is about 10 meters, and the load capacity is about 10 tons.

Secondly, there should be no dirt on the friction surface. If there is any dirt, it should be washed off with gasoline or thinner; The reduction gearbox, gearbox, external meshing gear, and other parts of the equipment as well as the hydraulic oil, must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found, replace it in a timely manner. The maintenance of the wire ropes must be carried out in strict accordance with the specifications; Check the connection condition of each part according to the braking rules and regulations. If there is any looseness, tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, whether there are noises and faults according to regulations, and promptly remove all faults; When installing, disassembling, and adjusting the rotating mechanism of the equipment, it is important to note that the reducer and the gear center line should be parallel, and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables, and if there is overheating of the motor. Replace the motor in a timely manner and eliminate the fault before continuing operation; Ensure that the bearings, boxes, distribution boxes, and that the travel switch points of each safety device must be safe and reliable.

Connect the motor to the elevator naturally. During connection, it must be ensured that the concentricity of the elevator output shaft and the motor input shaft is consistent, and that the outer flanges of the two are parallel. Inconsistent centering can cause the motor shaft to break or the elevator gear to wear.