Dunaharazti10 meter cargo elevatorMain measures to prevent pollution

announcer:hp779HP136589660 release time:2024-03-27 11:56:47

Unscrew the screws on the dustproof hole on the outer side of the elevator flange,DunaharaztiGuide rail chain elevator, adjust the PCS system ring to align its side hole with the dustproof hole,Dunaharazti5 ton lifting cargo elevator, and tighten with the hexagon socket. After that, remove the motor shaft key.

Walking: assisted self-propelled, two wheel traction, self driving,Dunaharazti10 meter cargo elevator, and car modification.

Dunaharazti.Many times, when ordering a large lifting platform, after the customer has determined the parameters, including the size during transportation, to prevent it from being difficult to transport to the customer's installation site after being too wide. Therefore during design and manufacturing, it is necessary to consider separate assembly or table split to meet the requirements. At the same time, it is also necessary to consider the bearing capacity of the split, design and manufacture on the premise of ensuring the load capacity and stability, and ensure that the equipment can be easily transported, lifted and moved.

Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes, with a scissors type mechanical mechanism, easy to maintain, strong stability, and high bearing capacity. The lifting height is about 10 meters, and the load capacity is about 10 tons.

.It is strictly prohibited for personnel to climb up and down the floors by using the goods elevator privately.

Walking: assisted self-propelled, two wheel traction self driving, and car modification.

'Using the elevator is not about maintaining and overhauling the equipment after it has failed. It is important to maintain the equipment in accordance with the correct maintenance and overhaul. First, do the preparatory work to eliminate all possible fault problems and accidents. I hope that today's summary of knowledge points by the editor can help everyone.'.


Dunaharazti10 meter cargo elevatorMain measures to prevent pollution



Regardless of whether it is used outdoors or indoors, it is inevitable that some small problems will occur after a long period of time. At this time, what we should do is to maintain and maintain the elevator. How to follow the steps correctly becomes a difficult problem. Let me explain it to you.

Remove and disassemble the hydraulic elevator lowering valve, blow out the plunger with compressed air, then install it and reinstall it.

For guideway elevators installed outdoors, they are often exposed to rain and sunlight, so special attention should be paid to regular maintenance and inspection to avoid accidents.

Quality improvement.Hydraulic lifting platforms are widely used in factory maintenance, and decoration of hotels in industrial and mining enterprises, with reliable quality and perfect performance.

Large logistics warehousing equipment service company with guaranteed prices and guaranteed services, directly operated by the manufacturer. Because fixed elevators are mechanical equipment, the quality and performance of the product are good. Do not accept products from some manufacturers that do not meet the quality standards, in order to avoid some safety hazards in use.

Prepare the foundation according to the foundation plan, pay attention to alignment, leveling, and alignment, and ensure the level of the foundation and various usage requirements.


Dunaharazti10 meter cargo elevatorMain measures to prevent pollution



Before installing the elevator, confirm whether the motor and the elevator are intact, and strictly check whether the dimensions of each part connecting the motor and the elevator match. Here are the dimensions and fit tolerances of the positioning boss, input shaft, and elevator groove of the motor.

Welcome calls .Motor connection error. When the triangular connection motor is mistakenly connected into a star shape, the motor still operates with full load, and the current flowing through the stator winding exceeds the rated current leading to the motor stopping itself. If the stopping time is slightly longer and the power supply is not cut off, the winding will not only be severely overheated, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch, the motor is mistakenly connected into two branches in parallel, both the windings and the iron core will overheat, and in severe cases, and the joints must not be loose. All joints must be tightened.

The cleanliness of the hydraulic station is an important aspect of the elevator hydraulic station, from a professional perspective, there are relevant rules and requirements. You should refer to the specification manual, so that you can have a correct understanding and know how to achieve better cleanliness.

Dunaharazti.Several types: motor winding open circuit. When one phase of the motor winding is open circuit, or one of the parallel branches is open circuit, it will cause three-phase current imbalance and cause the motor to overheat.

Many people believe that the mechanical strength of the elevator itself is relatively high when using the elevator, so the installation method specified in the manual is not strictly followed during the installation process. However, this can lead to increased wear of parts and inflexibility in operation. In addition, it is necessary to pay attention to the installation precautions corresponding to the working environment and not be careless. Correct installation, use, and maintenance of the elevator are important steps to ensure the normal operation of mechanical equipment. Therefore, when installing the elevator, please be sure to carefully assemble and use it in strict accordance with the following installation and use related matters.

Different. (Specific bearing capacity and lifting height can be designed and customized according to user requirements)