BaodingRail lift cargo elevatorEight key operating procedures

announcer:hp779HP136589660 release time:2024-03-20 09:18:47

The common types of elevators will be briefly introduced here. I hope you can have a better understanding of this product. Currently, because many places need to use this kind of product with lifting function and flexible movement. Now,Baoding5 ton cargo elevator, companies specializing in producing this type of product combine with extensive external publicity on the Internet, Friends in need can directly find the corresponding company on the Internet, and then have a brief understanding of the model, performance, and price information of these products. They can purchase directly through the Internet.

The load of this series of products is divided into 0.1 to 0.8 tons, with a load of up to 10 tons.

Baoding.Drain and discard the hydraulic oil from the hydraulic lifting cargo elevator. For the outdoor guide rail elevator tighten the joint and remove the oil filter. After cleaning, clean it with compressed air, and then return it to the oil tank and connect the pipeline.

Goods should be stacked well on the platform, and should not be tilted. When the goods elevator is lifting or lowering beyond the scope of the platform, no one should stand around to watch.

.The load of this series of products is divided into 0.1 to 0.8 tons, and can also be customized according to user requirements with a load of up to 10 tons.

Guide rail elevator (also known as cargo elevator) is a non scissor fork type hydraulic lifting platform, mainly used in industrial buildings, restaurants, restaurants, warehouses, docks, workshops, and other places where vertical cargo handling is required between two or more floors. The low height is particularly suitable for sites that are not suitable for digging pits on site. What issues should we pay attention to in these places where elevators are used?

Knowledge popularization and superior performance of scissor fork type fixed lifting platform: equipped with safety devices to prevent overloading of the lifting platform; Equipped with a protection valve to prevent hydraulic oil pipe from cracking; Equipped with an emergency lowering device for sudden power failure; The doors of the upper and lower floors are equipped with safety devices that interlock with the system.


BaodingRail lift cargo elevatorEight key operating procedures



Prepare the foundation according to the foundation plan, pay attention to alignment, leveling, and alignment, and ensure the level of the foundation and various usage requirements.

Main structure and purpose of guide rail type elevator: The mechanical part of guide rail type elevator mainly includes three parts: lifting device, track device, and belt changing device. The lifting device is mainly used to suspend the lifted person, which is the core part of the entire mechanism. The role of track device is mainly to provide movement trajectory, making operation more smooth. The belt changing device is used to switch tracks when the elevator is about to pass through the door. The internal structure of the lifting device is mainly composed of a gear mechanism, a bracket,Baoding3 ton fixed lifting cargo elevator, a worm gear, a lifting arm, upper and lower shells, etc. Gear mechanism Gear mechanism mainly includes large and small gears, winding pulley, central shaft, and safety device composed of stop buckle and torsion spring.

Incorrect connection of the elevator motor When a coil, coil group, or one phase winding group is connected inversely, it can cause a serious imbalance in the three-phase current and cause the winding to overheat.

Service first.Before connecting the motor to the elevator, the elevator manufacturer should first make the motor shaft keyway perpendicular to the tightening bolt. To ensure uniform stress, first screw on the mounting bolts at any diagonal position, but do not tighten them. Then screw on the other two mounting bolts at diagonal positions, and then tighten the four mounting bolts one by one. After that, tighten the tightening bolts. All tightening bolts shall be fixed with a torque wrench according to the indicated fixed torque data, and the use of elevators and lifting platforms shall be checked

Does the cleanliness of the hydraulic station have relevant rules and requirements?

It is strictly prohibited for personnel to climb up and down the floors by using the goods elevator privately.


BaodingRail lift cargo elevatorEight key operating procedures



Usage: Scissor fork type fixed lifting platforms are mostly used for goods transportation between height differences in production lines, adjusting the working height during workpiece assembly, feeding materials to loading machines at high altitudes, lifting components during assembly of large equipment, matching storage and loading sites with forklift trucks and other transportation vehicles for rapid loading and unloading of goods, vehicle lifting, fixed three-dimensional parking, and other places.

offer.Usage: Scissor fork type fixed lifting platforms are mostly used for goods transportation between height differences in production lines loading and unloading materials, adjusting the working height during workpiece assembly, feeding materials to loading machines at high altitudes,BaodingGuide rail lifting cargo elevator, lifting components during assembly of large equipment, matching storage and loading sites with forklift trucks and other transportation vehicles for rapid loading and unloading of goods, vehicle lifting, fixed three-dimensional parking, and other places.

Make sure to add butter twice a month to the transmission assembly where the grease fitting is located. For parts where butter cannot be added, it is necessary to dredge the oil circuit or replace the grease fitting until butter can be added otherwise it is prohibited to use the equipment.

Different. (Specific bearing capacity and lifting height can be designed and customized according to user requirements)

Baoding.Before installing the elevator, confirm whether the motor and the elevator are intact, and strictly check whether the dimensions of each part connecting the motor and the elevator match. Here are the dimensions and fit tolerances of the positioning boss, input shaft, and elevator groove of the motor.

Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that, remove the motor shaft key.

Is the water cooling and air cooling of the hydraulic station the same?