EmerodElectric high-altitude elevatorElements to improve thrust reliability

announcer:hp935HP175192871 release time:2024-01-19 15:55:42

The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

In addition to ground protective fences, a half height middle crossbar, and a toe board at least 150mm above the ground.

Emerod.Setting requirements: Construction electric elevators should be equipped with a down travel (limit) switch. The down travel (limit) switch should be able to automatically stop the cage running at rated speed before reaching the lower limit switch.

The list of materials for making landing doors is as follows: Table 1: List of materials for making landing doors. Landing doors should be installed at the entrance of each landing station, and the landing doors should function properly.

.When a rigid 5000mm2 square or circular flat surface is applied with a normal force of 600N to either side of the door, the door may not meet the above requirements, but safety should be maintained.

Civil engineering advantages: The pit depth of the guide rail type lifting platform is generally around 150-300mm, and the top layer is not affected. It can be customized according to the location and environment.

Setting requirements: Each landing entrance should be equipped with a landing door,EmerodElevator scissor electric, which should cover the opening with its full width, and should not open towards the lifting passage.


EmerodElectric high-altitude elevatorElements to improve thrust reliability



Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

The coaxiality between the motor shaft and the worm shaft in the aluminum alloy electric elevator drive device should be less than 0.1mm, and there should be a 2mm gap at the shaft end to ensure that the motor bearings bear reasonable loads and reduce motor operating noise; electric

The landing door should meet the requirements of the specifications and achieve standardization.

Statistics.Braking. The brake limit switch for partial motion control of the electric hoist traction machine. Assembly that restricts the operation of the lift car when it is opened to a high or low position; If the limit switch controls the overtravel switch. When the car travels to a high or low position, it will take on the function of raising or lowering. In order to prevent the lift car from crashing or sinking,EmerodElectric simple elevator, stage equipment should be dismantled with over travel switches that can cut off power and cannot be automatically reset, and installed in the machine room, rather than in the shaft; A buffer should be installed that can absorb the energy of the moving mechanism and reduce impact.

The quality of the standard section should comply with the product manual and specification requirements.

The verticality of the guide rail frame should meet the requirements of the specifications.


EmerodElectric high-altitude elevatorElements to improve thrust reliability



Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened,EmerodSimple electric hoist cargo elevator, whether the sealing rings are damaged or ineffective, whether there is a lack of hydraulic oil, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors, wiring, and oil cylinder once a week to avoid dust and debris affecting normal operation.

device management.Speed limit wire rope switch. When the speed limit wire rope trips or breaks. Make the electric elevator unable to start.

Attention should be paid to the occurrence of oil leakage on the aluminum alloy lifting platform to avoid secondary damage caused by a shortage of hydraulic oil. Overloading work is prohibited during use

The foundation base or embedded parts should be fully embedded in the concrete foundation plate.

Emerod.Once again weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective, whether there is a lack of hydraulic oil, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors wiring, routine inspections should be carried out according to regulations and inspection records should be filled out.

Buffer. In order to increase the energy for the car to hit the top or sink to the bottom. Remove rubber or sponge from the buffer and cabin to increase their impact energy; Rope groove slipping and other accidents caused the car to suddenly fall, resulting in a safety clamp. To prevent breakage of the lifting wire rope. A safety clamp that can simultaneously cut off the power supply and stop the car from falling should be removed from the car. A car without safety tongs is not allowed to ride or carry people. If it is a simple electric elevator, there should be a safety device (such as a safety stop pin) to prevent people from suddenly falling when loading and unloading goods in the car; Electric elevators with three or more floors (including three floors) for passengers or passengers.