Teveso8-meter hydraulic lifting platformPrice Index Weekly Review

announcer:hp695HP135175170 release time:2023-12-24 10:27:42

Hydraulic oil should be kept clean and replaced every 6 months; When repairing, maintaining, and cleaning the elevator, be sure to support the support rod.

What are the installation precautions for elevators? The folding fence and cage of the elevator should be cleaned of the foundation surface, and the foundation bolts should be installed properly. If the construction elevator is installed on the floor, a pad iron must be used below the screws to increase the force surface between the nuts and the floor to reduce the impact of the nuts on the floor; Insert steel plate shims of different thicknesses between the chassis and the foundation stone at the anchor bolts to adjust the verticality of the guide rail frame; Install three standard sections and measure the verticality of the guide rail frame using a theodolite to ensure the verticality of each main pipe in both directions. After adjusting the verticality of the guide rail frame, tighten the four foundation bolts; Adjust the verticality of the fence door frame as above and tighten the remaining anchor bolts; Install the buffer spring; Connect the other half of the fence to the front half with bolts; Adjust the verticality and tighten the anchor bolts as above,Tevesofork lifter, and release the brake on the motor inside the suspension cage. (For SC200/200 models, quality assurance, and promotional activities are underway. Welcome to consult

Check the hydraulic oil quality and level. When the lifting platform is raised to a high position, the hydraulic oil level should be 40-50 millimeters higher than the bottom of the oil tank. When the color of the hydraulic oil darkens, the oil becomes sticky or there are foreign objects such as gravel in the oil, the hydraulic oil should be replaced in a timely manner. The hydraulic system of the lifting platform should be checked for hydraulic and pipeline connections. If the pipeline is damaged, it should be replaced immediately; When there is looseness in the connection part, tighten the pipe joint.

.It is strictly prohibited to connect the motor of the lifting platform to the wrong power supply. It should be ensured that the voltage is 380V or 220V, and daily cleaning work should be carried out. Dust and debris on the motor should be cleaned in a timely manner.

Preparation before folding and installation of the elevator. Carefully prepare a special construction plan for installation and provide safety technical disclosure to the installation personnel.

For the safety performance of high-altitude work platforms, it is necessary to have production technology, scientific processes, and strict management to ensure production. When in use, people, the environment, and machines are the three major links of high-altitude operations, and safety is the basic condition to ensure the smooth progress of high-altitude operations. In the following text, Jiuyi briefly describes the precautions for using high-altitude operation platforms: high-altitude operators must hold a health certificate. Individuals suffering from intentional, high-pressure, or mental illness are not allowed to engage in high-altitude work tasks. Staff are not allowed to engage in high-altitude work while drinking alcohol or feeling mentally drained.


Teveso8-meter hydraulic lifting platformPrice Index Weekly Review



Precautions for daily maintenance of hydraulic elevator: Check all hydraulic pipelines and joints of the hydraulic elevator. The pipelines must not be damaged, and the joints must not be loose. All joints must be tightened.

Emergency bolts not tightened; The solution is to tighten the emergency valve.

When using the distribution box, the electric leakage switch meets the requirements for construction elevators. If the fixed elevator installed is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.

consumption.How to install and use the bearings of the elevator? During the process of using the bearing device of the elevator, we cannot always ensure that the bearing device has the right orientation, which inevitably leads to some devices not being in place or bearing displacement. Once these problems occur in the device, it will cause the clearance between the bearings to become too small, it is also necessary to use a testing instrument to test the bearing installation, in order to ensure the success of the bearing installation.

High altitude work requires the use of tool bags, and heavier and larger high-altitude work tools should be hung on stable components and cannot be placed randomly to avoid the occurrence of high-altitude falling accidents.

Although lifting cargo elevators have good safety, in practical work, if we do not pay attention to detailed maintenance, accidents may occur. Therefore, we should pay attention to them when performing daily maintenance.


Teveso8-meter hydraulic lifting platformPrice Index Weekly Review



The inconsistent rotation axis of the support rod in the middle of the hydraulic lifting platform results in the lifting platform being unable to function properly, causing serious damage to the platform and causing the table to tilt. Please carefully check that the general shear type high-altitude work platform was not strictly tested for tilt before leaving the factory, and was put into the market, causing many accidents. For small enterprises,TevesoHydraulic lifting platform, they are not very concerned about this aspect of tilt detection This is also why there are such a large number of lifting equipment with this problem. The problems with the oil cylinder and power unit system are often due to insufficient power and substandard oil cylinder quality, it must be replaced immediately. The maintenance and upkeep of steel wire ropes should strictly follow the 85 regulations.

This series of products has a load capacity of 0.1 to 0.8 tons which are also very important issues for enterprises themselves.

Customer first.Pay attention to checking each steel wire rope for broken wires and loose strands. If it exceeds the relevant regulations, and can also be customized according to user requirements, with a load capacity of up to 10 tons.

Check the hydraulic oil quality and level. When the lifting platform is raised to a high position, the hydraulic oil level should be 40-50 millimeters higher than the bottom of the oil tank. When the color of the hydraulic oil darkens, the oil becomes sticky, or there are foreign objects such as gravel in the oil, the hydraulic oil should be replaced in a timely manner. The hydraulic system of the lifting platform should be checked for hydraulic and pipeline connections. If the pipeline is damaged, it should be replaced immediately; When there is looseness in the connection part, tighten the pipe joint.

Teveso.What are the common faults of hydraulic lifting platforms? The hydraulic lifting platform's oil cylinder is severely damaged, resulting in uneven lifting height of the oil cylinder. It is recommended to carefully check whether the oil cylinder is normal.

Motor does not rotate: The motor is broken, and the manufacturer will handle it. We are a long-term manufacturer of scissor type elevators. Welcome to inquire

Firstly, it is necessary to use and operate the elevator correctly. The operators should receive systematic operation training: regular inspection of operating standards should be conducted, and any violations of the elevator operation should be punished immediately. In severe cases, they should be transferred from this position. Since the passing of