Agnel sur SeineElectric banner elevatorDetailed introduction of common problems and solutions

announcer:hp935HP175192871 release time:2023-12-04 18:13:04

Speed limit wire rope switch. When the speed limit wire rope trips or breaks. Make the electric elevator unable to start.

Steel wire ropes, pulleys, and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T20118; Maintenance, wear, deformation, and corrosion of steel wire ropes

Agnel sur Seine.Fully autonomous lifting is widely used in various high-altitude work fields, such as factory maintenance, airport maintenance, street light maintenance,Agnel sur SeineElectric one ton elevator, and so on; How to use electric elevators correctly to extend the service life of the equipment and be flexible

Chain type electric lifting mechanism: With a good guiding mechanism, it can ensure that the equipment does not tilt during operation. Gear and rack electric lifting mechanism: precise transmission and high cost.

.The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

Setting requirements: The installation and dismantling workers, electricians, and other operators of construction electric elevators should have special construction operations.


Agnel sur SeineElectric banner elevatorDetailed introduction of common problems and solutions



Human improper operation is the main factor causing malfunctions in scissor type electric elevators. When stacking goods electric elevators should stack the goods neatly, which is better than stacking them in the center of the cargo stacking area of the cargo elevator to avoid imbalance between the two ends of the stacking area. Eventually, during the operation of the electric elevator, it may cause the electric elevator to lose balance. After the goods are stacked completely, ropes should be used to lock the goods, so that they are not afraid of the goods during the lifting process; Careless; Scattered down

The usual operation of landing and docking. The installation position of the upper limit switch should comply with the following: when the lifting speed is less than 0.8m/s, the upper safety distance L left after the upper limit switch is triggered by the hanging cage should not be less than

The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.

Quality inspection report.Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

Buffer. In order to increase the energy for the car to hit the top or sink to the bottom. Remove rubber or sponge from the buffer and cabin to increase their impact energy; Rope groove slipping and other accidents caused the car to suddenly fall, there should be a safety device (such as a safety stop pin) to prevent people from suddenly falling when loading and unloading goods in the car; Electric elevators with three or more floors (including three floors) for passengers or passengers.

To ensure safe and reliable braking of the lifting platform and prevent accidents a hydraulic control one-way valve, also known as a hydraulic lock, and; Program adjustment time delay to avoid frequent movement of electric elevators that may affect their service life.


Agnel sur SeineElectric banner elevatorDetailed introduction of common problems and solutions



When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm,Agnel sur SeineTricycle electric elevator, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

target.The use of standard section connecting bolts should comply with the user manual and specification requirements.

After the limit switch is activated, only professional personnel can restore the movement of the suspension cage.

Then, the lifting platform platform platform that carries the load needs to be balanced, and no deviation of one side is allowed. The lifting of goods does not allow people to stand on both sides of the platform, and the lifting of goods should try to maintain a stable and uniform speed.

Agnel sur Seine.Construction electric elevators outside the lightning protection range

Later, when there is a major malfunction of the lifting platform, it should be repaired by professional personnel as soon as possible. After the malfunction occurs, it should not be used again to avoid accidents, personnel and property losses.

From the perspective of the safety performance of the machinery itself, those that have undergone national safety certification will not have significant safety issues. The main problem is that after using the electric elevator for a period of time, mechanical components may fall off or be damaged due to various factors. This problem depends on regular inspection and maintenance of the machinery