Hamburg BergdorfElectric banner elevatorHow to do independent research and development

announcer:hp935HP175192871 release time:2024-09-07 14:01:16

The advantages and disadvantages of several commonly used electric lifting mechanisms are as follows: hydraulic electric lifting mechanisms: using hydraulic technology smooth lifting and low noise.

Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation,Hamburg BergdorfScissor fork electric lifting platform, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

Hamburg Bergdorf.Electric elevators should be regularly maintained and cleaned. During maintenance and cleaning, the bracket should be supported to prevent the electric elevator from overturning. Electrical and hydraulic systems should be maintained by professional personnel; When the battery level display is less than 40%

Before installation, the installation unit should confirm that the foundation,Hamburg BergdorfPure electric curved arm elevator, foundation bearing capacity, embedded parts, concealed engineering acceptance form, and concrete strength report.

.Steel wire ropes, pulleys, and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T20118; Maintenance, deformation, and corrosion of steel wire ropes

After the electric elevator passes the inspection, the user unit shall organize the leasing unit installation unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.

Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.


Hamburg BergdorfElectric banner elevatorHow to do independent research and development



Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.

During maintenance or when problems occur, the power supply should be cut off in a timely manner. After lifting the aluminum alloy electric elevator should be firmly fixed before maintenance can be carried out. It is strictly prohibited to operate with defects to avoid accidents.

The advantages and disadvantages of several commonly used electric lifting mechanisms are as follows: hydraulic electric lifting mechanisms: using hydraulic technology, smooth lifting and low noise.

device management.Especially suitable for steel structured factories, suitable for both indoor and outdoor installation.

When the wall bracket adopts non matching standard products, design calculations should be carried out.

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.


Hamburg BergdorfElectric banner elevatorHow to do independent research and development



Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator, the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.

Safety and health.Before installation, the installation unit should confirm that the foundation,Hamburg BergdorfElectric vertical elevator, foundation bearing capacity, embedded parts, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form, and concrete strength report.

The isolation and buffering rubber in various parts of the aluminum alloy electric elevator drive device are intact and tightly fitted.

Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

Hamburg Bergdorf.Setting requirements: Before starting work every day and changing shifts, the driver of the construction electric elevator should inspect the construction electric elevator according to the requirements of the user manual and specifications, record the inspection results, and report any problems found to the user unit.

The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve, hydraulic control one-way valve, throttle valve, and explosion-proof electromagnetic directional valve. To ensure a smooth descent of heavy objects and safe and reliable braking, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure, so that the descent speed does not change due to heavy objects. The throttle valve regulates the flow rate and the ascending and descending speed.

Chain type electric lifting mechanism: With a good guiding mechanism, it can ensure that the equipment does not tilt during operation. Gear and rack electric lifting mechanism: precise transmission and high cost.