PSV EindhovenElectric elevator batteryThe foundation of industry development

announcer:hp935HP175192871 release time:2024-07-17 11:44:49

Especially suitable for steel structured factories, suitable for both indoor and outdoor installation.

From the perspective of the safety performance of the machinery itself, those that have undergone national safety certification will not have significant safety issues. The main problem is that after using the electric elevator for a period of time, fracture, as well as generate impact pressure in the hydraulic system, which in turn can damage hydraulic components, oil seals, and high-pressure oil

The net height of the landing door opening should not be less than 8m, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

.Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).

There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

When the wall bracket cannot meet the requirements of the construction site it should be designed and calculated separately.


PSV EindhovenElectric elevator batteryThe foundation of industry development



Before installation, the installation unit should confirm that the foundation, foundation bearing capacity, embedded parts, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form, and concrete strength report.

Setting requirements: Buffers should be installed below the suspension cage and counterweight running channel.

According to the needs of different performance genres, the form of the stage can be changed. For example, using an orchestra pit lift can combine a framed stage with a large lip or even an extended stage. In an experimental theater, using a lift can make the theater have various forms such as an end stage, an extended stage, an island stage, an intermediate stage, a T-shaped stage, or a hall.

Customer first.The full height landing door should meet the following requirements: the net height of the landing door opening should not be less than 0m. In special circumstances,PSV EindhovenElevator electric small, when the net height of the building entrance is less than 0m, it is allowed to lower the height of the lower door opening,PSV EindhovenDingli Electric Elevator, but in any case the net height of the lower door opening is not less than 8m. (Article 1 of GB26557-2011)

Civil engineering advantages: The pit depth of the guide rail type lifting platform is generally around 150-300mm, and the top layer is not affected. It can be customized according to the location and environment.

The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements,PSV EindhovenPlatform electric elevator, otherwise protective measures shall be taken.


PSV EindhovenElectric elevator batteryThe foundation of industry development



The use of a lifting platform as a tool for storing performance blankets, soft scenery, etc. In some theaters, there is a soft scenery storage lifting platform located at an appropriate location on the stage for the storage of blankets, soft scenery, etc.

How much does it cost?.The verticality of the guide rail frame should meet the requirements of the specifications.

The shutdown device (emergency stop switch) should be non automatic reset type.

The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.

PSV Eindhoven.Especially suitable for steel structured factories, suitable for both indoor and outdoor installation.

The use of standard section connecting bolts should comply with the user manual and specification requirements.

Setting requirements: The installation and dismantling workers electricians, and other operators of construction electric elevators should have special construction operations.