Check valve leakage: If the natural wear of the check valve exceeds the specified value after long-term use, it will cause leakage. Disassemble and clean the check valve, and replace it if necessary.

The hydraulic oil used in the system has the same brand, and the oil temperature is between 45~80 ℃. Use a large flow rate to remove impurities from the system as much as possible. The hydraulic system needs to be cleaned repeatedly three times or more, and after each cleaning, the system should be drained while the oil is hot. After cleaning, clean the filter and add new oil after using a new filter element.

Zamoshik.There are two installation methods for hydraulic freight elevator oil cylinders: jacking and lifting. The difference between jacking and lifting is that the placement direction of the oil cylinder is opposite, which is a qualitative problem and easy to arrange. The disadvantage is that the effective use of the oil cylinder can lift the same load, and the oil cylinder of the lifting mechanism is much larger than that of the lifting mechanism. Professional elevator manufacturers and other special products, 20 year old brand, with price advantages and guaranteed quality

After long-term use of the automatic lifting platform equipment it is inevitable that some malfunctions will occur. In order not to affect work, it is necessary to promptly solve the difficulties in starting the motor and abnormal sounds. Generally, insufficient power supply, and a small cross-sectional area of the power supply cable, the starting voltage drop is too large and the price of the cargo elevator is reduced.

. There is air in front of the pilot valve of the elevator overflow valve noise overflow valve. The damping hole on the main valve core of the overflow valve is blocked by oil dirt,ZamoshikIndoor fixed hydraulic lifting platform, and the pilot valve and valve seat are matched without spring deformation or incorrect installation. The remote control port has excessive oil flow, low or high hydraulic oil viscosity, and resonance occurs with components in the circuit. Troubleshooting: Strengthen sealing, repeatedly adjust the pressure, exhaust and clean the valve body several times, Make the damping hole unobstructed, reduce the flow of the remote control port, replace the oil, and other components. The pressure setting of other components should not be similar to the pressure setting of the relief valve. 5. The noise of the elevator pipeline is usually caused by excessive dead bends or loose fixed sleeves in the hydraulic pipeline.

When the hydraulic oil is insufficient, the hydraulic pump will experience suction, causing air to enter the hydraulic oil and producing high noise.

Before installation, the installation personnel should confirm the infrastructure such as the foundation and shaft, leveling, and alignment points, such as cylinder mounted elevators and there are also some forms of elevators that are not common, curved arm elevators, car mounted elevators, etc. Their common feature is the hydraulic principle for operation, because the stability of the hydraulic system can bring better user experience and safer operation to the equipment, which has been favored by many users.

Oil cylinder leaks. Long term use causes wear on the sealing ring in the oil cylinder and excessive oil leakage in the cylinder wall gap, resulting in the natural descent of the hydraulic cargo elevator. The sealing components need to be replaced immediately.

Car mounted lifting platform: The car mounted lifting platform is designed to improve the mobility of the lifting platform by fixing it to a transport vehicle or truck. It receives power from the car engine and achieves the lifting function of the car mounted lifting platform. To adapt to high-altitude operations inside and outside the factory area.

The cost is reasonable.The optional configurations of a fixed lifting platform include manual hydraulic power, movable flip plates that are easy to overlap with surrounding facilities, rolling or motorized roller tracks, safety contact bars to prevent foot rolling,ZamoshikIndoor hydraulic lifting platform, organ type safety protective covers, manual or motorized rotating workbenches, safety support rods to prevent the lifting platform from falling, stainless steel safety nets, electric or hydraulic lifting platform walking power systems, and universal ball countertops.

The vibration range is proportional to the lifting height. The higher the height, the larger the shaking range, especially for mobile hydraulic cargo elevators. When the working height exceeds 10 meters, the wind ropes at the four corners of the hydraulic cargo elevator should be tightened to strengthen leg protection, increase stability, and reduce shaking.

The vibration range is proportional to the lifting height. The higher the height, the larger the shaking range, especially for mobile hydraulic cargo elevators. When the working height exceeds 10 meters, the wind ropes at the four corners of the hydraulic cargo elevator should be tightened to strengthen leg protection, increase stability, and reduce shaking.


ZamoshikHydraulic lifting platform experimentMethod of weighing



The precautions to consider when selecting a hydraulic lift oil tank include: considering the structure of the oil tank, the partition in the traditional oil tank cannot settle dirt. A vertical partition should be installed along the longitudinal axis of the oil tank, with a space left between one end of the partition and the end plate of the oil tank to connect the gaps on both sides of the partition. The inlet and outlet of the hydraulic pump are arranged on both sides of the partition at the disconnected end so that the distance Z between the inlet and return oil is far, The hydraulic oil tank has more heat dissipation effect.

original.Pay attention to checking each steel wire rope for signs of broken wires and loose drums. If it exceeds the relevant rules, it is necessary to replace it immediately. The protection of steel wire ropes should strictly follow the rules of GB5144-85.

When working at heights, except for relevant personnel no one is allowed to walk or stay below the workplace. Fencing or other protective devices should be installed below the workplace to prevent falling objects from injuring people.

Next,ZamoshikElectric fixed hydraulic lifting platform, the hydraulic cargo elevator manufacturer will explain the maintenance of the mechanical equipment of the elevator: the brakes of each organization should be frequently checked and adjusted to ensure the clearance between the brake pads and wheels is sensitive and reliable. On the surface, there should be no dirt present. If there is dirt, it is necessary to wash it off with gasoline or thinner.

Zamoshik.When encountering signs of overheating in the electric motor, it is necessary to park the car in a timely manner, clean the problem, and continue running. The motor bearings should be smooth and outstanding.

The main device does not engage. When this fault occurs, check whether the three-phase power supply is normal, whether the internal and external emergency stop button switches, the electric lock switch are turned on, whether the three-phase electrical phase sequence is correct, and whether the relay working indicator light is on.

When disassembling and adjusting the reverse organization of the equipment, attention should be paid to ensuring that the centerline of the reverse organization reducer is parallel to the centerline of the gear, and its meshing surface is not less than 70%. The meshing gap should be appropriate.