KarlsruheStraight top hydraulic lifting platformReturn to stability

announcer:hp695HP135175170 release time:2024-05-25 18:21:48

Before installing the elevator bearings, do not open the packaging too early. This can easily lead to premature bearing contamination which can lead to premature bearing damage. Additionally, ensure that the installation environment is clean and do not bring iron filings, dust and other objects into the bearings. Even small dust particles can cause premature bearing damage,Karlsruhe15 meter hydraulic lifting platform, Prolonged use can also affect the running in between bearings, leading to a decrease in the lifespan of the elevator.

The reduction gearbox,KarlsruheChanging manual hydraulic lifting to electric hydraulic lifting, gearbox, external meshing gear and other parts, as well as the hydraulic oil, are all carried out according to the requirements in the table. Professional scissor lift manufacturer with high prices, service, on-site settlement, and honest operation!

Karlsruhe.Hydraulic pump station: domestic lifting platform dedicated pump station, Italian imported pump station with external protective devices: organ m type, mesh type,KarlsruheElectric hydraulic lifting platform truck, and iron plate sealed type.

After careful inspection, it was found that it was mainly caused by two reasons

.During use, the elevator should be placed on a solid and flat ground to prevent tipping during operation. Press&quo; Rising; Or&quo; Descending; Press the button to frequently check and maintain the various components of the elevator when lifting the workbench. If the workbench does not move, it should be immediately stopped for inspection. When the working pressure of the electric elevator is found to be too high or the sound is abnormal, it should be immediately shut down for inspection to avoid serious mechanical damage; Regularly check the working status of the shaft pin every month. If any loose shaft pin or screw is found, it must be locked tightly to prevent accidents caused by the shaft pin falling off.

Elevators are now very popular among people and can easily transport goods to high-rise buildings. Among them, hydraulic elevators are more popular among people, and people can choose the one that suits them according to their actual situation. However, during normal work, it is important to pay attention to the lifting speed of hydraulic elevators and avoid making mistakes. So what factors will affect the lifting speed of hydraulic elevators?

Elevators are now very popular among people and can easily transport goods to high-rise buildings. Among them, and people can choose the one that suits them according to their actual situation. However, during normal work, the electric leakage switch meets the requirements for construction elevators. If the fixed elevator installed is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.

Characteristics of hydraulic elevators: Hydraulic lifting platform products are divided into curved arm hydraulic lifting machines, mast hydraulic elevators, and straight arm hydraulic elevators according to their working modes. Hydraulic elevator is a replacement product of folding arm elevator (lifting platform) and scissor fork elevator (lifting platform). It can be widely used in stations, docks, airports, hotels, posts and telecommunications, municipal gardens, garages, cleaning, decoration of public building facades, installation and maintenance of power systems, and so on. This elevator has the advantages of light weight, electric starting, self supporting legs, simple operation, large working area, and especially the ability to cross obstacles for high-altitude operations.

Loosening: The motor fan makes a sound when it rotates. If the screws that fix the motor are loose, coupled with its own vibration, the motor collides with other components, resulting in a sound; The joints of each pin shaft are dry, lacking oil, and there is hard friction between the iron parts, which not only damages the components but also produces abnormal noises. Therefore, the editor should emphasize again that timely maintenance and frequent refueling are important; If the hydraulic lifting platform does not rise, there is air in the hydraulic oil. You can open the exhaust hole, add gas, and then tighten it again; Hydraulic oil solidification: replace the hydraulic oil; Oil leakage: Check if there is any oil leakage at the interfaces of each oil pipe. If there is any oil leakage, replace it in a timely manner; Motor reversal: Check for wiring errors; (Manufacturers of hydraulic lifting platforms who do not understand electricity in a timely manner)

device management.Any product always has a break-in period when it is first used, so what precautions should we pay attention to during the break-in period when using a hydraulic lifting platform? Today, the editor will share this topic with everyone.

Good stability: The overflow valve can prevent excessive system pressure during upward movement. Emergency manual valve: In case of power failure, it can cause the elevator car to descend to the nearest floor position and open the door. Manual pump: When the system malfunctions, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops.

The second is that the steel will have obvious thermal expansion effect at low temperature. Although this property of steel will be taken into account when designing and manufacturing hydraulic elevators, the environment is different after all. Under low conditions, the steel will have some unstable performance, such as hardness increase, toughness decline, etc. At this time, more attention should be paid to the maintenance of equipment to keep key parts to avoid dry grinding.


KarlsruheStraight top hydraulic lifting platformReturn to stability



Precautions for daily maintenance of hydraulic elevator: Check all hydraulic pipelines and joints of the hydraulic elevator. The pipelines must not be damaged, and the joints must not be loose. All joints must be tightened.

equipment maintenance .Do not adjust the solenoid valve on the motor arbitrarily. The solenoid valve is pre adjusted before leaving the factory, and random adjustment can easily cause internal pressure to increase or decrease. In severe cases, it can shorten the service life of the motor.

Hydraulic pump station: domestic lifting platform dedicated pump station, Italian imported pump station with external protective devices: organ m type, mesh type, and iron plate sealed type.

Are there any damages to the wires and cables of the department. We need to quickly bandage and replace the damaged department.

Karlsruhe.Carefully prepare a special construction plan for installation and provide technical disclosure to the installation personnel. I have been engaged in various types of scissor lift manufacturers and other materials for many years and operate with integrity. Welcome to call!

When encountering overheating in the electric motor during daily maintenance of the elevator, it is necessary to quickly park the car, remove obstacles and then continue running. The motor bearings should be smooth and excellent.

What are the installation precautions for elevators? The folding fence and cage of the elevator should be cleaned of the foundation surface, and the foundation bolts should be installed properly. If the construction elevator is installed on the floor, a pad iron must be used below the screws to increase the force surface between the nuts and the floor to reduce the impact of the nuts on the floor; Insert steel plate shims of different thicknesses between the chassis and the foundation stone at the anchor bolts to adjust the verticality of the guide rail frame; Install three standard sections and measure the verticality of the guide rail frame using a theodolite to ensure the verticality of each main pipe in both directions. After adjusting the verticality of the guide rail frame, tighten the four foundation bolts; Adjust the verticality of the fence door frame as above and tighten the remaining anchor bolts; Install the buffer spring; Connect the other half of the fence to the front half with bolts; Adjust the verticality and tighten the anchor bolts as above and release the brake on the motor inside the suspension cage. (For SC200/200 models, first install the suspension cage before installing the drive plate).