MILUSLifting table hydraulic pressureWhat are the selection techniques

announcer:hp695HP135175170 release time:2024-05-19 13:41:26

Working at heights is a common practice nowadays, but it also has a certain degree of danger. So people invented hydraulic lifting platforms, which are more convenient to help people complete high-altitude operations. However, otherwise they can easily malfunction, which may lead to serious consequences. So what are the common faults of hydraulic lifting platforms?

The explanation mainly focuses on the mechanism of lifting platforms, and now there are many different types of lifting platforms. In order to better use lifting platforms, we have started to develop different industries using different lifting platforms. Electric lifting platforms have become the main product of small lifting platforms. They are small in size, light in weight, practical in appearance,MILUSHydraulic lifting platform cargo elevator, large in load capacity, and large in plane area, Stability has become a machinery that many customers are competing for, and lifting equipment is used in enterprises of all sizes, so the use of lifting platforms is necessary.

MILUS.The indicator light is on, press the up button, the motor rotates but the lifting table does not rise. Check≥ Phase power supply, after the power supply is reversed,MILUSIndoor hydraulic lifting platform car, the motor reverses, and only needs to correct the power supply.

Although lifting cargo elevators have good safety, in practical work, if we do not pay attention to detailed maintenance, accidents may occur. Therefore, we should pay attention to them when performing daily maintenance.

.Before installing the elevator bearings, do not open the packaging too early. This can easily lead to premature bearing contamination, which can lead to premature bearing damage. Additionally, ensure that the installation environment is clean and do not bring iron filings, dust, and other objects into the bearings. Even small dust particles can cause premature bearing damage, Prolonged use can also affect the running in between bearings, leading to a decrease in the lifespan of the elevator.

Talking about the daily maintenance and use of hydraulic lifting platform motors. Overloading is strictly prohibited, as overloading can increase the burden on the motor and in severe cases, cause the motor to burn out.

When working in a hot environment, pay attention to heat dissipation.


MILUSLifting table hydraulic pressureWhat are the selection techniques



High altitude work is now also very common, and elevators are also highly demanded by the market. Many high-rise transportation tasks are completed by elevators, attention should also be paid to the installation of the elevator, otherwise there may be problems, and no one wants to see such a situation happen. What are the installation precautions for elevators?

The hydraulic pipeline is probably congested. The hydraulic pipeline is also a particularly important key, checking whether the hydraulic pipeline is smooth. Focus on checking whether there are signs of congestion or jamming in various hydraulic valves including one-way stop valves, electromagnetic directional valves, proportional control valves, overflow valves, etc. If there are problems, the hydraulic valve should be cleaned or replaced in a timely manner, as the hydraulic oil may deteriorate or contain impurities. After the hydraulic oil is permanently used, there may be impurities or deterioration in the hydraulic oil. Take a sample for inspection to see if it contains fluid particles, discoloration, or odor. If necessary, replace the hydraulic oil.

What are the installation precautions for elevators? The folding fence and cage of the elevator should be cleaned of the foundation surface, and the foundation bolts should be installed properly. If the construction elevator is installed on the floor, a pad iron must be used below the screws to increase the force surface between the nuts and the floor to reduce the impact of the nuts on the floor; Insert steel plate shims of different thicknesses between the chassis and the foundation stone at the anchor bolts to adjust the verticality of the guide rail frame; Install three standard sections and measure the verticality of the guide rail frame using a theodolite to ensure the verticality of each main pipe in both directions. After adjusting the verticality of the guide rail frame, tighten the four foundation bolts; Adjust the verticality of the fence door frame as above and tighten the remaining anchor bolts; Install the buffer spring; Connect the other half of the fence to the front half with bolts; Adjust the verticality and tighten the anchor bolts as above, and release the brake on the motor inside the suspension cage. (For SC200/200 models first install the suspension cage before installing the drive plate).

superior quality.During use, the elevator should be placed on a solid and flat ground to prevent tipping during operation. Press&quo; Rising; Or&quo; Descending; Press the button to frequently check and maintain the various components of the elevator when lifting the workbench. If the workbench does not move, it should be immediately stopped for inspection. When the working pressure of the electric elevator is found to be too high or the sound is abnormal, it should be immediately shut down for inspection to avoid serious mechanical damage; Regularly check the working status of the shaft pin every month. If any loose shaft pin or screw is found it must be locked tightly to prevent accidents caused by the shaft pin falling off.

Hydraulic oil should be kept clean and replaced every 6 months; When repairing, maintaining, and cleaning the elevator, be sure to support the support rod.

The boxes and distribution boxes of hydraulic elevators should be kept clean regularly, and dust on electrical equipment should be promptly cleaned.


MILUSLifting table hydraulic pressureWhat are the selection techniques



Check the rollers, intermediate shafts, and all technical indicators meet the design requirements. When in use, only the power supply needs to be connected, and the hydraulic and electrical systems basically do not need to be adjusted.

The indicator light is on, press the up button, the motor rotates but the lifting table does not rise. Check≥ Phase power supply, after the power supply is reversed, the motor reverses, and only needs to correct the power supply.

Regularly check whether the operation of each mechanism is normal and whether there is any noise. If any faults are found, they must be promptly eliminated. For a long time, the manufacturer of scissors lift has never changed hands to avoid price difference, and the price is 20% higher than the market value! More than one ton is more expensive!

MILUS.When using the distribution box the electric leakage switch meets the requirements for construction elevators. If the fixed elevator installed is variable frequency, the selection of the leakage switch should be compatible with the frequency converter.

Talking about the daily maintenance and use of hydraulic lifting platform motors. Overloading is strictly prohibited as overloading can increase the burden on the motor and in severe cases, cause the motor to burn out.

When encountering overheating in the electric motor during daily maintenance of the elevator, it is necessary to quickly park the car, remove obstacles, and then continue running. The motor bearings should be smooth and excellent.