neutralElectric elevator lifting by 4 metersCommon faults and troubleshooting methods

announcer:hp935HP175192871 release time:2024-05-14 15:57:59

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

When the wall bracket adopts non matching standard products, design calculations should be carried out.

neutral.Setting requirements: Construction electric elevators should be equipped with a down travel (limit) switch. The down travel (limit) switch should be able to automatically stop the cage running at rated speed before reaching the lower limit switch.

To ensure safe and reliable braking of the lifting platform and prevent accidents, a hydraulic control one-way valve, also known as a hydraulic lock, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure. Electrical system explosion-proof button SB1&flash; The rotation of the SB6 motor and the commutation of the explosion-proof electromagnetic directional valve are used to maintain load increase or decrease,neutralElectric elevator small, and; Program adjustment time delay to avoid frequent movement of electric elevators that may affect their service life.

.Work is essential, and the main protective accessories include safety belts, guardrails, protective covers, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops


neutralElectric elevator lifting by 4 metersCommon faults and troubleshooting methods



The function of the lifting platform in a theater is roughly as follows: the main lifting platform arranged in the main performance area of the stage is mainly used to quickly change the scenery. Typically, with&quo; Product; In the music and dance theater stage arranged in a zigzag pattern,neutralElectric elevator mobile type, the lifting platform, side car platform, and rear car turntable perform a rapid transformation of the entire or partial scene. This arrangement allows for rapid switching of three full sets.

Setting requirements: Steel wire rope electric elevators and reusable steel wire ropes should be equipped with anti loosening rope devices, which should have compliant loosening rope switches and be able to interrupt any movement of the cage until it passes through the

Civil engineering advantages: The pit depth of the guide rail type lifting platform is generally around 150-300mm, and the top layer is not affected. It can be customized according to the location and environment.

A complete range of products.Steel wire ropes, pulleys, and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T20118; Maintenance, wear, deformation, and corrosion of steel wire ropes

Emergency manual valve: In case of power failure, it can cause the car to descend to the nearest floor position and open the door

Low level doors should be equipped with interlocking devices that can verify their closed and locked positions. The action of this interlocking device should be at the entrance of the cage. Simple use should not interfere with the operation of the interlocking device. The attached wall bracket should use matching standard products. When the wall bracket cannot meet the requirements of the construction site, it should be designed separately. The design of the wall bracket should meet the requirements of component stiffness, strength, stability, etc., and the production should meet the design requirements.


neutralElectric elevator lifting by 4 metersCommon faults and troubleshooting methods



When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

Administration.Emergency manual valve: In case of power failure, it can cause the car to descend to the nearest floor position and open the door

Requirements for the operation platform of the construction lowering machine and the setting of the brake reset emergency stop switch: The shutdown device (emergency stop switch) should be able to stop or maintain the electric elevator (including the power driven door) in a non working state

Setting requirements: For construction electric elevators with foundations installed on roof slabs floors, or other lower suspended structures, the bearing capacity of the foundation support structure should be checked. Click here to download the construction technical information for free. Basic drainage facilities should be installed.

neutral.Use floor doors and cage door devices on construction sites where conditions permit.

The bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.

As a material loading and unloading equipment recognized by customers in the lifting platform the guide rail hydraulic lifting platform is superior in terms of product, civil engineering,neutral2 ton electric elevator, and operating costs. The editor of the electric elevator will provide a detailed analysis: the advantages of the product are that the equipment bears a large load, can achieve multiple points, and can be controlled up and down floors to achieve safe use.