HardenbachElectric elevatorPurchasing needs

announcer:hp935HP175192871 release time:2024-05-05 16:11:06

It is reported that a fixed electric elevator has good lifting stability and can only be used for fixed operations, it worked normally.

Hardenbach.The water cooling of hydraulic stations is generally tubular water cooling. The selection is based on the heat load to calculate the heat exchange area, while the air-cooled electric elevator uses an air cooler to calculate the heat exchange capacity based on the heat load. Then, the selection calculation is carried out under the condition of satisfying the flow rate. So, these two types of cooling are different and have significant differences.

The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve, hydraulic control one-way valve, throttle valve and explosion-proof electromagnetic directional valve. To ensure a smooth descent of heavy objects and safe and reliable braking, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure so that the descent speed does not change due to heavy objects. The throttle valve regulates the flow rate and the ascending and descending speed.

.Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.

Double layer steel mesh: The diameter of the steel bars is 12mm, with a spacing of 200mm.

Low power consumption: When the hydraulic guide rail lifting platform descends, it is driven by the pressure generated by its own weight, greatly saving energy and reducing consumption.


HardenbachElectric elevatorPurchasing needs



During loading and unloading, the horizontal distance between the edge of the cage door and the edge of the landing station should not exceed 50mm.

The movement of its related components is direct.

The hydraulic oil forms a certain pressure by the vane pump, explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve,HardenbachMicro electric elevator,HardenbachSmall electric hydraulic elevator, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).

Home page recommendation.High lifting height, using side mounted oil cylinders, stable operation, noise free, easy maintenance, and longer service life.

There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

High lifting height, using side mounted oil cylinders, stable operation, noise free, easy maintenance, and longer service life.


HardenbachElectric elevatorPurchasing needs



The landing door should be in a normally closed state. Without the permission of the construction electric elevator driver, the landing door shall not be opened.

Excellent service.Setting requirements: Before starting work every day and changing shifts, the driver of the construction electric elevator should inspect the construction electric elevator according to the requirements of the user manual and specifications, record the inspection results,HardenbachMicro electric elevator, and report any problems found to the user unit.

Setting requirements: Construction electric elevators should be equipped with a down travel (limit) switch. The down travel (limit) switch should be able to automatically stop the cage running at rated speed before reaching the lower limit switch.

Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

Hardenbach.News Abstract: The development of the lifting platform industry will continue to grow in recent years! With the continuous development of electric lifting machinery for high-altitude operations in recent years, the products of electric lifting platform vehicles have been continuously improved, and various new technologies and materials have emerged, making the further development of lifting platform vehicles possible.

Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.

During the use period, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.