RotlingenBackground axis electric elevatorWhat are the ways to control the amount

announcer:hp935HP175192871 release time:2024-04-14 10:34:21

Setting requirements: The wall bracket should use the manufacturer's matching standard products.

Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.

Rotlingen.During maintenance or when problems occur,RotlingenElectric hydraulic elevator platform, the power supply should be cut off in a timely manner. After lifting, the aluminum alloy electric elevator should be firmly fixed before maintenance can be carried out. It is strictly prohibited to operate with defects to avoid accidents.

There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

.Model Example: Hanging Cage Specification: LABSC200/200TD3200x1500 Type I: 2900~3600 Type II: 2900~3600 Type V: 1800~250044003800 Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x0.02 (kN).

The quality of the standard section should comply with the product manual and specification requirements.

When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.


RotlingenBackground axis electric elevatorWhat are the ways to control the amount



Buffer. In order to increase the energy for the car to hit the top or sink to the bottom. Remove rubber or sponge from the buffer and cabin to increase their impact energy; Rope groove slipping and other accidents caused the car to suddenly fall, resulting in a safety clamp. To prevent breakage of the lifting wire rope. A safety clamp that can simultaneously cut off the power supply and stop the car from falling should be removed from the car. A car without safety tongs is not allowed to ride or carry people. If it is a simple electric elevator, there should be a safety device (such as a safety stop pin) to prevent people from suddenly falling when loading and unloading goods in the car; Electric elevators with three or more floors (including three floors) for passengers or passengers.

Requirements for the operation platform of the construction lowering machine and the setting of the brake reset emergency stop switch: The shutdown device (emergency stop switch) should be able to stop or maintain the electric elevator (including the power driven door) in a non working state

When the landing door is closed, the full width of the lifting passage opening should be covered.

build.The L distance depends on the selected wall mount model.

During normal operation,RotlingenThree phase electric elevator, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

When the wall bracket adopts non matching standard products, design calculations should be carried out.


RotlingenBackground axis electric elevatorWhat are the ways to control the amount



Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops

The cost is reasonable.Electric elevators used in various places.

When a single steel wire rope is excessively stretched, the Electrical safety device shall stop the operation of the electric lift.

Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

Rotlingen.Secondly,RotlingenInstallation of electric elevators for fire protection, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

During loading and unloading, the horizontal distance between the edge of the cage door and the edge of the landing station should not exceed 50mm.

Use floor doors and cage door devices on construction sites where conditions permit.