MadisonBackground axis electric elevatorThe regional economic development is generally stable

announcer:hp935HP175192871 release time:2024-04-04 13:11:51

The full height landing door should meet the following requirements: the net height of the landing door opening should not be less than 0m. In special circumstances, when the net height of the building entrance is less than 0m, it is allowed to lower the height of the lower door opening, but in any case, the net height of the lower door opening is not less than 8m. (Article 1 of GB26557-2011)

Low level doors should be equipped with interlocking devices that can verify their closed and locked positions. The action of this interlocking device should be at the entrance of the cage. Simple use should not interfere with the operation of the interlocking device. The attached wall bracket should use matching standard products. When the wall bracket cannot meet the requirements of the construction site, it should be designed separately. The design of the wall bracket should meet the requirements of component stiffness, strength, stability etc., and the production should meet the design requirements.

Madison.The safety overtravel of limit switches and upper limit switches should comply with regulatory requirements.

Advantages of electric elevator rotary valve: Simplify the installation of electric elevator pipelines; The operation is more convenient,MadisonDedicated electric elevator, and the valve can be opened and closed at any time; The installation of a rotary valve reduces the friction of the sealing components; Compact structure small size, and space saving; Increased the service life of electric elevator pipelines and solved the problem of easy oil leakage.

.During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

Chain type electric lifting mechanism: With a good guiding mechanism, it can ensure that the equipment does not tilt during operation. Gear and rack electric lifting mechanism: precise transmission and high cost.

The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.


MadisonBackground axis electric elevatorThe regional economic development is generally stable



Setting requirements: For construction electric elevators with foundations installed on roof slabs,MadisonElectric hoist, floors, or other lower suspended structures, and there should be a 2mm gap at the shaft end to ensure that the motor bearings bear reasonable loads and reduce motor operating noise; electric

Especially suitable for steel structured factories, a hydraulic control one-way valve, also known as a hydraulic lock, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure. Electrical system explosion-proof button SB1&flash; The rotation of the SB6 motor and the commutation of the explosion-proof electromagnetic directional valve are used to maintain load increase or decrease, and; Program adjustment time delay to avoid frequent movement of electric elevators that may affect their service life.

Especially suitable for steel structured factories, suitable for both indoor and outdoor installation.

The use of a lifting platform as a tool for storing performance blankets, soft scenery, etc. In some theaters, there is a soft scenery storage lifting platform located at an appropriate location on the stage for the storage of blankets, soft scenery, etc.


MadisonBackground axis electric elevatorThe regional economic development is generally stable



Steel wire ropes, pulleys, and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T20118; Maintenance, wear, deformation, and corrosion of steel wire ropes

Home page recommendation.Stage equipment safety door. To prevent personnel from extending their heads, hands, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.

Construction electric elevators should be equipped with upper limit switches that are sensitive and reliable.

Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.

Madison.The scissor type electric elevator is a widely used high-altitude operation special equipment. Its scissor mechanical structure ensures high stability of the lifting platform, wide working platform, and high bearing capacity, making the high-altitude operation range wider and suitable for multiple people to work simultaneously. It makes high-altitude operation more efficient and safer

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, timely inspection of various functions is essential.