The net height of the landing door opening should not be less than 8m, except for the gap between the lower part of the door that should not exceed 35mm,MishkoltzTatami electric elevator, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

Mechanical devices controlled by cage movement should not be used to open or close the landing door.

Mishkoltz.The impact load can cause early wear, fracture, and fragmentation of mechanical structural components, as well as generate impact pressure in the hydraulic system, which in turn can damage hydraulic components, oil seals and high-pressure oil

The counterweight guide rail should meet the specification requirements.

.Use floor doors and cage door devices on construction sites where conditions permit.

During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed 150mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.


MishkoltzElectric chain elevatorDevelopment history



During loading and unloading,Mishkoltz3 meter electric elevator, the horizontal distance between the edge of the cage door and the edge of the landing station should not exceed 50mm.

The movement of its related components is direct.

The pump body adopts an integrated pump station, all equipped with imported high-quality pump stations which can also be selected according to customer requirements to meet customer ideal requirements.

equipment maintenance .When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

Speed limit wire rope switch. When the speed limit wire rope trips or breaks. Make the electric elevator unable to start.

Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.


MishkoltzElectric chain elevatorDevelopment history



Setting requirements: The quality of the standard section should meet the requirements of the product manual. Before installing the construction electric elevator, all components should be inspected,MishkoltzFixed electric hydraulic elevator, and standard sections and other components with severe wear and deformation should be replaced.

Quality Assurance.When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test, it worked normally.

Normal operation starts. Click on this free download of construction technical information. Safety limit devices should be installed on electric elevators for construction, with upper and lower limit switches that are sensitive and reliable.

With the continuous improvement of urbanization level in China, the number of high-rise buildings in urban areas has sharply increased, and the height of buildings has also continued to grow. This has created a demand for high-altitude lifting platform vehicles. Therefore, in order to meet the needs of the domestic market and the public, efforts will inevitably be made to design and produce high-altitude lifting platform vehicles.

Mishkoltz.Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.

When the door is closed, except for the gap between the lower part of the door that should not exceed 35mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

When the landing door is closed, the full width of the lifting passage opening should be covered.