DebrecenMast type aluminum alloy hydraulic lifting platformOperation precautions

announcer:hp530HP141750488 release time:2024-03-13 11:32:12

The hydraulic lifting platform is a manually movable type, and the lifting power of the platform is a two machine or three-phase power supply. It has manual and electric power, and is also equipped with a hand pump for use in case of power outage. This series of platforms have the characteristics of flexible movement, stable lifting, and easy operation, and are mainly used in factories, government agencies, commercial stores, and the construction and decoration industry.

The elevator itself has a simple structure and is easy to maintain, which has been favored by a large number of enterprises and individual customers. Hydraulic elevator is a multifunctional heavy loading and unloading mechanical equipment. The lifting system of hydraulic elevators is driven by hydraulic pressure, also known as hydraulic powered elevators.

Debrecen.In on-site hydraulic elevators, it is difficult to detect the rising position, middle position, impact noise,DebrecenCustomized hydraulic lifting platform, seriously affecting production efficiency. The unstable hydraulic lifting requires an analysis of the hydraulic oil flow rate. Hydraulic pressing oil has poor quality and contains a large amount of impurities, which can also prevent slow and unstable lifting. In addition, there are other reasons: lifting the composition of the hydraulic ring. Oil pump, safety valve, directional valve,DebrecenHydraulic lifting platform cargo elevator, directional valve, one-way throttle valve (without throttling), and lifting cylinder.

The hydraulic oil used in the system has the same brand, and the oil temperature is between 45~80 ℃. Use a large flow rate to remove impurities from the system as much as possible. The hydraulic system needs to be cleaned repeatedly three times or more and after each cleaning, the system should be drained while the oil is hot. After cleaning, clean the filter and add new oil after using a new filter element.

.Check valve leakage: If the natural wear of the check valve exceeds the specified value after long-term use, it will cause leakage. Disassemble and clean the check valve, and replace it if necessary.

Hydraulic lift cargo elevators belong to high-altitude work equipment. Small shaking of the scissor type structure is normal, but excessive deviation is a symptom. It is necessary to find the cause and make correct judgments in a timely manner. Generally speaking, operations above 8 meters are generally allowed. Due to its own weight, devices above this height begin to vibrate in different ranges. The vibration range depends on factors such as weight, lifting height, and intensity of high-altitude operations.

Regularly check whether each organization is functioning properly and whether there is noise. If problems are found, they should be promptly cleaned up.


DebrecenMast type aluminum alloy hydraulic lifting platformOperation precautions



When installing, disassembling, and adjusting the rotating mechanism, attention should be paid to ensuring that the middle line is parallel to the middle line of the gear, and its meshing surface is not less than 70%. The meshing clearance should be suitable for the brakes of each mechanism. The clearance between the brake wheels should be regularly checked and adjusted to ensure its flexibility and reliability. There must be no dirt on the friction surface and it must be cleaned with gasoline or diluent.

What are the benefits of hydraulic cargo elevators compared to traditional elevator cargo transportation?

Before installation, pay attention to alignment, leveling, and alignment points, and confirm that the foundation meets the requirements before construction.

Honesty and mutual benefit.The hydraulic pump produces noise. When the hydraulic elevator rises, the hydraulic pump runs at high speed. If there is a problem with the gears or bearings of the hydraulic pump, which causes periodic changes in the hydraulic system pressure, it will also cause resonance in the hydraulic system and generate noise.

An inverter can also generate high noise. When the power supply voltage is lower than 85% of the rated voltage, dust or rust is poor the surface of the magnetic yoke and armature is skewed, and the device will produce; Buzz&# quo; Noise.

After 5000 hours of elevator operation, carry out medium maintenance on the mechanical and electrical systems.


DebrecenMast type aluminum alloy hydraulic lifting platformOperation precautions



Materials enter the production line at one end of the factory building and the production process ends at the other end of the factory building with multiple separate platforms; This can greatly shorten the distance of material flow in the factory building.

Quality improvement.The contact of the travel switch must be firmly opened and closed, and the contact crater should be polished in a timely manner.

In winter, when working outdoors at heights below minus 10 degrees Celsius, heating rest areas should be set up near the construction area if necessary. Heating equipment should be managed by dedicated personnel and attention should be paid to fire prevention.

The development of elevators is at its peak, as many manufacturers have chosen more multi-story buildings to fully utilize the site, so they also need a device to facilitate the improvement of goods.

Debrecen.Selection of the location of the loading and unloading lifting platform In order to reduce the cost of material handling, the location of the platform should be selected to minimize the distance of the handling tools and vehicles in the factory. It is much easier to move a fully loaded transport vehicle to a designated location outside the building than to transport the loaded materials one by one to the designated location indoors. When selecting a platform location, full consideration should be given to the production process and operational needs of the factory. There are two modes of platform layout: merging: loading and unloading on the same platform.

Stability: The workbench should evenly withstand 125% of the MAX load capacity and be stable at the MAX elevation.

Lines of various safety equipment