HaHandmade children's hydraulic lifting platformWhat's and what's the use

announcer:hp530HP141750488 release time:2024-03-04 14:42:35

To consider its capacity, generally mobile equipment takes 2-3 times the high flow rate of pump Z, and fixed equipment takes 3-4 times.

When using an electric mobile scissor lifting platform outdoors, if the wind force exceeds level 5, please stop using it; When the lifting height exceeds 10 meters, the wind ropes at the four corners of the hydraulic lift platform should be tightened and fixed, and the support legs should be reinforced for protection and stability to avoid safety accidents caused by excessive swinging of the electric lifting platform

Ha.When the hydraulic cargo elevator needs to work, first connect the power supply and press the button to drive the motor of the hydraulic power unit to drive the gear pump. The hydraulic oil forms a certain pressure through the vane pump and passes through the oil filter; Explosion proof electromagnetic directional valve; Throttle valve; Hydraulic control one-way valve; The balance valve enters the lower end of the hydraulic cylinder, causing it to move upwards and lift heavy objects. The hydraulic cylinder moves downwards (i.e. the weight drops), the explosion-proof electromagnetic directional valve of the hydraulic oil enters the upper end of the hydraulic cylinder, and the return oil from the lower end of the hydraulic cylinder passes through the balance valve; Hydraulic control one-way valve; Throttle valve, explosion-proof electromagnetic directional valve.

Do you know the classification of simple cargo elevator lifting platforms? The manufacturer of the hydraulic cargo elevator is here to inform you.

.The precautions to consider when selecting a hydraulic lift oil tank include: considering the structure of the oil tank, the partition in the traditional oil tank cannot settle dirt. A vertical partition should be installed along the longitudinal axis of the oil tank, with a space left between one end of the partition and the end plate of the oil tank to connect the gaps on both sides of the partition. The inlet and outlet of the hydraulic pump are arranged on both sides of the partition at the disconnected end, so that the distance Z between the inlet and return oil is far,HaIndoor hydraulic lifting platform car, The hydraulic oil tank has more heat dissipation effect.

Electrical equipment or component failures. Hydraulic elevator manufacturers tell you that the main reasons for high noise generated by electric motors are: bent or severely worn motor rotors, or damaged bearings, which cause electric motors to sweep and produce noise; The cooling fan of the electric motor is damaged or not firmly fixed, resulting in high noise; The electric motor is not firmly fixed and can also cause vibration, producing high noise.

What are the methods for reducing shaking on lifting platforms? Reducing the shaking of the lifting platform can reduce the psychological obstacles of the operators, ensure the smooth progress of the operation, and also greatly help improve safety. Warm reminder: safety, do not operate blindly. Lifts are widely used in many places and their working principles vary. Today, This type of elevator uses hydraulic oil cylinders and pump stations to transmit power we will analyze the working principles of elevators. The types of elevators are generally divided into the following: fixed elevators, in the form of a scissor fork type. According to customer requirements,HaSmall hydraulic lifting platform, the length of the support rod for the scissor fork the number of layers, the angle of the angle axis, and the expansion and contraction of the oil cylinder complete the lifting operation. Its advantages are large load-bearing capacity, stable lifting, and high safety.


HaHandmade children



The contact of the travel switch must be firmly opened and closed,HaDouble fork hydraulic lifting platform, and the contact crater should be polished in a timely manner.

Operating cost advantage: Low failure rate: Due to the use of hydraulic systems and good methods, the failure rate of elevator operation can be reduced to a low level.

Do you know the classification of simple cargo elevator lifting platforms? The manufacturer of the hydraulic cargo elevator is here to inform you.

Honesty and mutual benefit.The hydraulic elevator overflow valve can also generate high noise. When air is mixed in hydraulic oil, the overflow valve is stuck or severely worn, the spring of the overflow valve is fatigued and deformed, resulting in unstable pressure regulation of the overflow valve, and the relief time of the overflow valve is too short, it is easy to cause the pilot valve performance of the overflow valve to be partially stable, causing air to vibrate inside the pilot valve and generate noise. So we need to regularly clean the overflow valve. When the overflow valve is damaged or severely worn, it should be replaced.

Do you know the classification of simple cargo elevator lifting platforms? The manufacturer of the hydraulic cargo elevator is here to inform you.

If the circuit of the device is not disconnected or lowered, it is necessary to check the fuse for repair and replacement.


HaHandmade children



The classification of lifting platforms is as follows: they are divided into mobile lifting platforms, automatic lifting platforms, folding arm lifting platforms, and sleeve type lifting platforms according to their different modes of movement.

Service first.The manufacturer of hydraulic cargo elevators will tell you about the knowledge of specialized lifting platforms for unloading.

Hydraulic oil deteriorates or produces impurities. After long-term use of oil pressure, there may be impurities or deterioration in the oil. Sampling inspection should be carried out to see if there are solid particles, discoloration, and odor. If necessary, the oil should be changed. There may be blockage in the hydraulic pipeline of the hydraulic cargo elevator. The hydraulic pipeline is also a very important part, and it is necessary to check whether the hydraulic pipeline is smooth. Focus on checking whether each type of hydraulic valve includes one-way globe valve, electromagnetic directional valve, proportional control valve, overflow valve, etc. If there are problems the hydraulic valve should be cleaned or replaced in a timely manner.

Electrical equipment or component failures. Hydraulic elevator manufacturers tell you that the main reasons for high noise generated by electric motors are: bent or severely worn motor rotors, which cause electric motors to sweep and produce noise; The cooling fan of the electric motor is damaged or not firmly fixed, resulting in high noise; The electric motor is not firmly fixed and can also cause vibration, producing high noise.

Ha.Reason: Cleaning method for internal leakage in the oil cylinder: Replace the sealing element of the oil cylinder. The lifting platform does not lower. Reason: The lowering valve is malfunctioning. Cleaning method: When pressing the lowering button, check whether the lowering valve is powered on. If there is no electricity, clean it as much as possible; If there is power, hydraulic mechanism, electric mechanism, and support mechanism. The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge.

Ensure that there is a suitable power supply at the installation site, and separate maintenance of the distribution box is required. The distribution box should have a leakage switch, and the hydraulic cargo elevator construction site should be equipped with a fire extinguisher to prevent welding operations from causing fires. When selecting a leakage switch, it should be suitable for the operating power.