The contact opening and closing of the travel switch of each safety device must be reliable, scientific processes, and strict management to ensure production. When in use, people, the environment, and machines are the three major links of high-altitude operations, and safety is the basic condition to ensure the smooth progress of high-altitude operations. In the following text,MainzMobile hydraulic lifting platform, Jiuyi briefly describes the precautions for using high-altitude operation platforms: high-altitude operators must hold a health certificate. Individuals suffering from intentional, high-pressure, or mental illness are not allowed to engage in high-altitude work tasks. Staff are not allowed to engage in high-altitude work while drinking alcohol or feeling mentally drained.

Mainz.Loose or leaking connection between the oil suction pipe and the gear pump; The solution is to tighten the suction pipe.

In the construction elevator, the switch box also has leakage protection equipment and its wires and cables have good insulation without leakage. The metal passing through the wires is not rusted, without any issues of strand breakage or shrinkage and its damage is close to zero. His steel wire rope should comply with the corresponding configuration requirements, and of course, the number of broken wires should not exceed the corresponding standards. His pulley movement is very flexible.

.After entering winter, which requires users to perform seasonal maintenance and upkeep on the elevator. Below, the editor will briefly introduce the winter maintenance precautions and key points of the elevator.

The inconsistent rotation axis of the support rod in the middle of the hydraulic lifting platform results in the lifting platform being unable to function properly, causing serious damage to the platform and causing the table to tilt. Please carefully check that the general shear type high-altitude work platform was not strictly tested for tilt before leaving the factory, and was put into the market, causing many accidents. For small enterprises, they are not very concerned about this aspect of tilt detection, This is also why there are such a large number of lifting equipment with this problem. The problems with the oil cylinder and power unit system are often due to insufficient power and substandard oil cylinder quality, which are also very important issues for enterprises themselves.

The boxes and distribution boxes of hydraulic elevators should be kept clean regularly, and dust on electrical equipment should be promptly cleaned.


MainzAutomatic hydraulic lifting platformWhy does the air volume become smaller after using it for a long time



Regularly check all wires and cables for damage. Timely bandage and replace damaged parts. Various scissor lift manufacturers have formal qualifications. Welcome to inquire by phone and sincerely invite cooperation!

Having a high social status, it has now become an irreplaceable part of our mainstream goods. And the hydraulic pump station is the heart position of the lifting machinery, which extremely tests the professionalism and attention of the operator. It is our common responsibility to inspect it and ensure the daily use of machinery. Let's take a look at several common sense issues: the elevator manufacturer's point is to ensure the correctness of the power connection, and there should be no misconnection or leakage; Pay attention to cleaning work in daily life and do not allow stains to corrode it; When standing still, regular maintenance should be carried out to prevent the impact of rain and snow weather; Overloading is the first thing that operators must comply with; Iron Law&# quo;; The adjustment of the solenoid valve cannot be done arbitrarily and must be checked and certified by a professional organization; Especially when conducting outdoor operations under high temperatures, it is necessary to always pay attention to the abnormalities of the pump station; It is very normal for us to encounter some problems when using hydraulic boarding bridges as long as these problems are not very serious, we don't have to worry too much. However, when there is a problem with the hydraulic boarding bridge, only a timely solution is the correct response. Below is an introduction to some common faults of the hydraulic boarding bridge and specific solutions: the hydraulic boarding bridge must be repaired while hanging and supporting the working platform of the lifting platform to avoid sudden descent of the lifting platform, causing unnecessary casualties; 2. Do not adjust the overflow valve arbitrarily. Because every component in the hydraulic system operates at a specified pressure, once the relief valve is adjusted, it may cause abnormal operation of the hydraulic system, causing unnecessary damage to people, machines, and objects; Non professional personnel are not allowed to disassemble electrical appliances at will to prevent electric shock or incorrect connection.

Staying below high-altitude work sites is prohibited, and safety nets or other protective devices should be installed below the work site to avoid injury from falling objects.

Administration.It is strictly prohibited to connect the motor of the lifting platform to the wrong power supply. It should be ensured that the voltage is 380V or 220V and daily cleaning work should be carried out. Dust and debris on the motor should be cleaned in a timely manner.

What are the advantages of installing a guide rail type elevator for goods? The advantages of civil engineering are easy to install: there is no need for a machine room above the shaft, and the top layer can be installed at a height of more than 5 meters. The computer room can be located within a radius of 15 meters of the shaft, occupying an area of only 3-4 square meters. The hydraulic elevator is not equipped with a counterweight device to improve the utilization rate of the shaft area. The load and load cylinder of the hydraulic elevator directly act on the foundation pit,MainzFixed hydraulic elevator, and the strength requirement for the shaft is low. A brick structure or brick concrete structure shaft is sufficient.

The correct construction inspection of the airport is to first inspect the foundation to see if there is any water accumulation and to see if the grounding system meets the requirements. We also need to see how the structural bolts of this frame are tightened, and whether there are any cracks in the welds. We need to set them according to the instructions. In mechanical transmission, it can be divided into two types: open type and closed type. Of course, there are also many safety equipment for elevators.


MainzAutomatic hydraulic lifting platformWhy does the air volume become smaller after using it for a long time



Mobile elevators are generally used in skyscrapers where electric elevators are used, as there is no need to stop midway, so fast elevators are needed. First go to the high-rise sky lobby (high-rise elevator lobby, Skylobby) from the ground, and then transfer to the ordinary elevator to the destination. Some new elevators use elevator pre calling systems, which can pre call designated floors in the lobby. These passenger elevators can be decorated beautifully according to customer needs. Some passenger elevators are also equipped with air conditioning and television, while others are set up in the cabin, so that customers can enjoy the scenery outside while riding.

Recommendation and consultation.Replace with new oil and do not intermittently use old oil, otherwise the moving parts in the system will accelerate wear.

When the motor connection of the elevator is incorrect, when a coil, coil group, or one phase winding group is connected in reverse, it can cause serious three-phase current imbalance and cause the winding to overheat.

Precautions for daily maintenance of hydraulic elevator: Check all hydraulic pipelines and joints of the hydraulic elevator. The pipelines must not be damaged,MainzManufacturer of scissor lift, and the joints must not be loose. All joints must be tightened.

Mainz.When encountering overheating in the electric motor during daily maintenance of the elevator, it is necessary to quickly park the car, remove obstacles, and then continue running. The motor bearings should be smooth and excellent.

Maintain a smooth access road for external construction elevators and sufficient parking space for equipment. When using a crane for auxiliary installation, pay attention to heat dissipation.