HajidunasElectric tricycle hydraulic elevatorWhat are the work items for maintenance

announcer:hp935HP175192871 release time:2024-02-23 10:13:21

The use of standard section connecting bolts should comply with the user manual and specification requirements.

Implementing multiple shifts of homework should fill in and submit records according to regulations.

Hajidunas.Try to use this equipment in areas with wind force less than level five, and avoid using it when the wind force is too strong to avoid accidents.

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

.Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

It is understood that the scissor type lifting platform is a widely used specialized equipment for high-altitude operations. Its shear fork mechanical structure provides high stability for the lifting platform, wide working platform, and high load-bearing capacity, making the range of high-altitude operations larger and suitable for multiple people working simultaneously. The lifting power is divided into 24V, 220V or 380V power supplies, diesel engines, using Italian and domestic hydraulic pump stations, and the table top is equipped with anti slip insulation buckle plates, which have anti slip, insulation, and safety features. Please rest assured to use.

The foundation base or embedded parts should be fully embedded in the concrete foundation plate.


HajidunasElectric tricycle hydraulic elevatorWhat are the work items for maintenance



Civil engineering advantages: The pit depth of the guide rail type lifting platform is generally around 150-300mm, and the top layer is not affected. It can be customized according to the location and environment.

The detailed reason why water cannot be used to flush the hydraulic station is that doing so will corrode the oil tank in the hydraulic station, and once water is mixed in the hydraulic station, it will simply form pipeline corrosion water vaporization,HajidunasFully electric self-propelled elevator, it is necessary to prevent such actions to ensure the normal operation and service life of the hydraulic station.

Model Example: Hanging Cage Specification: LABSC200/200TD3200x1500 Type I: 2900~3600 Type II: 2900~3600 Type V: 1800~250044003800 Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x0.02 (kN).

target.Speed limiter. To prevent the driving speed from exceeding the normal speed. A speedometer should be installed (not required for floors below or including the second floor) and other phenomena that can cause adverse effects or results for hydraulic electric elevators. Therefore, which is an individual mechanism that is integrated with a safety clamp; The entrance and exit of the passenger compartment should be equipped with safety doors. Public places, family dormitories, and

When the wall bracket adopts non matching standard products, design calculations should be carried out.

Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops


HajidunasElectric tricycle hydraulic elevatorWhat are the work items for maintenance



The landing door should be in a normally closed state. Without the permission of the construction electric elevator driver, for the replacement of hydraulic oil on the lifting platform, it is recommended to replace it every three months. If the frequency of use is not high, it can be replaced once a year. The hydraulic oil must be clean, and after changing the hydraulic oil, it must be automatically lifted and lowered 2 to 3 times to ensure that the air in the oil cylinder is completely discharged, maintain sufficient space,HajidunasElectric three wheel car lift, and ensure that the lifting platform can be lifted to the rated lifting height.

The pressure joint between the pipe joint and the rubber hose fails prematurely,HajidunasElectric hydraulic elevator, causing oil leakage or pipe explosion. The oil temperature rises due to frequent action of the overflow valve.

Every theater is a public place with a large number of people, and safety considerations should be taken into account in stage design. According to relevant national regulations, in order to prevent accidents caused by the crushing of electric elevators or improper control by drivers. Electric elevators should be equipped with the following necessary safety devices to ensure that the car of the electric elevator stops rising or falling in a timely manner.

Hajidunas.Setting requirements: Each landing entrance should be equipped with a landing door, which should cover the opening with its full width, and should not open towards the lifting passage.

Mechanical devices controlled by cage movement should not be used to open or close the landing door.

Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.