SolingenFully self-propelled electric elevatorQuality improvement

announcer:hp935HP175192871 release time:2024-02-10 11:41:06

When the landing door is closed, the full width of the lifting passage opening should be covered.

Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.

Solingen.The down travel (limit) switch should be of the automatic reset type.

It is understood that the scissor type lifting platform is a widely used specialized equipment for high-altitude operations. Its shear fork mechanical structure provides high stability for the lifting platform, wide working platform, and high load-bearing capacity, 220V or 380V power supplies, diesel engines using Italian and domestic hydraulic pump stations, and the table top is equipped with anti slip insulation buckle plates, which have anti slip, insulation,SolingenElectric elevator, and safety features. Please rest assured to use.

.When the wall bracket adopts non matching standard products, design calculations should be carried out.

The wall bracket of the construction electric elevator should be intact and reliably fixed and its attachment distance, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.

Setting requirements: Each landing entrance should be equipped with a landing door, which should cover the opening with its full width, and should not open towards the lifting passage.


SolingenFully self-propelled electric elevatorQuality improvement



From the above comparison, it can be seen that hydraulic electric lifting mechanisms have stable lifting, large load bearing capacity long service life, and are relatively simple, making them suitable for use in stage equipment.

Non automatic reset upper and lower limit switches should be installed at both the upper and lower ends of the stroke, which should be able to cut off the power supply before the suspension cage and other mechanical stop devices (such as buffers),

Model Example: Hanging Cage Specification: LABSC200/200TD3200x1500 Type I: 2900~3600 Type II: 2900~3600 Type V: 1800~250044003800 Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x0.02 (kN).

Promotion.There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

Horizontal lead screw mechanical electricity

There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.


SolingenFully self-propelled electric elevatorQuality improvement



High lifting height, using side mounted oil cylinders, stable operation, noise free, easy maintenance, and longer service life.

Packaging strategy.Stage equipment safety door. To prevent personnel from extending their heads, hands, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed,SolingenElectric lifting scissor lift,SolingenElectric self-propelled elevator, its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.

Precautions for safe use of electric elevators: Before use, remove any obstacles or debris near the electric elevator that may hinder operation, and check whether the operating handle can be used normally.

When the door is closed, any through-hole and opening size related to the distance between any door and adjacent moving parts, as well as the gap around the door or the gap between parts, should comply with the provisions of Table 4 of GB 23821-2009.

Solingen.The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.

The quality of the standard section should comply with the product manual and specification requirements.

Installation and dismantling personnel and drivers should hold certificates to work.