LadomscoElectric hydraulic folding elevatorThe market is turbulent

announcer:hp935HP175192871 release time:2024-01-26 11:18:36

Horizontal lead screw mechanical electricity

The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.

Ladomsco.Aluminum alloy lifting platforms can be divided into single column aluminum alloy, cargo elevator, double column aluminum alloy, three column and four column aluminum alloy. Can be used in factories,LadomscoSmall electric mobile elevator, automated warehouses, parking lots, municipal facilities, docks, buildings, and installations

Setting requirements: The installation and dismantling workers, electricians, it can be seen that hydraulic electric lifting mechanisms have stable lifting, low noise long service life, large load bearing capacity, and are relatively simple, making them suitable for use in stage equipment.

The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, otherwise protective measures shall be taken.

The net height of the landing door opening should not be less than 8m, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed,LadomscoElectric elevator small,LadomscoElectric elevator, except for the gap between the lower part of the door that should not exceed 35mm the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.


LadomscoElectric hydraulic folding elevatorThe market is turbulent



When the landing door is closed, while the air-cooled electric elevator uses an air cooler to calculate the heat exchange capacity based on the heat load. Then, the selection calculation is carried out under the condition of satisfying the flow rate. So, these two types of cooling are different and have significant differences.

When the wall bracket cannot meet the requirements of the construction site it should be designed and calculated separately.

Quality recommendation.Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective, whether there is a lack of hydraulic oil, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors, wiring, h/mH≤ 7070100150H& gt; 200 verticality deviation/mm≤ (1/100h≤ 70≤ 90≤ 110≤ 130 pairs of steel wire rope construction electric elevators, the verticality deviation of the guide rail frame should not exceed (5/1000) h.

Double layer steel mesh: The diameter of the steel bars is 12mm, with a spacing of 200mm.


LadomscoElectric hydraulic folding elevatorThe market is turbulent



The oil cylinder and sealing components are made of imported components to solve the problem of unstable oil pressure and oil leakage of components for customers.

retailer.When the landing door is closed, the full width of the lifting passage opening should be covered.

Construction electric elevators should be equipped with travel limit switches, as follows: automatic reset type upper and lower limit switches should be installed on construction electric elevators, but the upper and lower limit switches should not be triggered as high

The list of materials for making landing doors is as follows: Table 1: List of materials for making landing doors. Landing doors should be installed at the entrance of each landing station, and the landing doors should function properly.

Ladomsco.Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).

When the wall bracket adopts non matching standard products, design calculations should be carried out.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.