Agnel sur SeineHydraulic lifting table smallNurtured by quality

announcer:hp530HP141750488 release time:2023-11-08 13:30:18

The elevator is evenly distributed at any position on the guide rail at 150% of the maximum load capacity, and should be stable at the maximum lifting height.

The above are the working principles of three common elevators, and there are also some forms of elevators that are not common, such as cylinder mounted elevators, etc. Their common feature is the hydraulic principle for operation,Agnel sur Seine8-meter hydraulic lifting platform, because the stability of the hydraulic system can bring better user experience and safer operation to the equipment, which has been favored by many users.

Agnel sur Seine.Cleaning and maintenance: When there is oil in the oil tank or when oil is refilled, it is necessary to ensure the cleanliness of the filter tank cover. Clean the oil and funnel or container before use. Never bring dirty things into the system, only clean oil.

The guide rail type elevator has a structure of a straight top oil cylinder. The linear operation of the oil cylinder pulls the transmission chain driving the lifting of the table to complete the operation. The guide rail type elevator is a popular form of cargo elevator in recent years, with the advantages of higher lifting height, stable operation, and simple maintenance compared to the scissor fork type elevator.

.Reason: The lowering valve is not tightly closed. Cleaning method: Check if the lowering valve is powered on. If there is no power supply, and the workbench is evenly loaded to 125% of the maximum load capacity. After lifting 100 times, each load-bearing component must not have deformation or cracks.

When the hydraulic system malfunctions, the hydraulic elevator may experience problems with the hydraulic pump, motor, valve, and hydraulic installation after repairing the hydraulic system, which can easily cause vibration and generate significant noise.


Agnel sur SeineHydraulic lifting table smallNurtured by quality



Hydraulic cargo elevators have been used in some high-altitude operations in recent years, and now some hydraulic cargo elevators are gradually mentioned as large machinery such as tower cranes, becoming a better choice for some high-altitude operations. However there are still certain limitations, such as height and improving the quality of goods, which have certain constraints.

The above are common situations, and there are many other reasons based on the actual situation. Hydraulic lift cargo elevators can have different configurations according to the installation environment and usage requirements of the factory building.

The electromagnetic coil of the electromagnetic directional valve is not firmly fixed, and frequent separation and suction can also produce high noise.

manufacturer.Reason: Manual pump and gear pump have severe oil leakage. Cleaning method: Replace the oil pump sealing ring to clean it. Reason: Gear pump is damaged, The oil pumped out has no pressure. Cleaning method: Replace the gear pump to clean the problem. Reason: Lack of hydraulic oil. Cleaning method: Add enough hydraulic oil to clean the problem. Reason: Circuit open. Cleaning method: Check the button and fuse to clean the problem. Reason: Filter blockage. Cleaning method: Replace or clean the problem. Reason: Support valve or electromagnetic directional valve malfunction. There are two situations: the input voltage of the electromagnetic coil is lack of 220V. The solenoid coil is burnt out and the valve core is stuck. Cleaning method: maintenance or replacement can be used to clean the natural descent of the lifting platform. Reason and cleaning method: one-way valve leakage cleaning method: check the check valve in the valve. Assuming there is dirt on the sealing surface of the check valve. Clean the check valve.

An inverter can also generate high noise. When the power supply voltage is lower than 85% of the rated voltage, the short circuit ring of the iron core of the device breaks,Agnel sur SeineHydraulic straight top lifting platform, the surface of the magnetic yoke and armature is skewed, dust or rust is poor, and the device will produce; Buzz&# quo; Noise.

There is air in front of the pilot valve of the elevator overflow valve noise overflow valve. The damping hole on the main valve core of the overflow valve is blocked by oil dirt, and the pilot valve and valve seat are matched without spring deformation or incorrect installation. The remote control port has excessive oil flow, low or high hydraulic oil viscosity, and resonance occurs with components in the circuit. Troubleshooting: Strengthen sealing, repeatedly adjust the pressure, exhaust and clean the valve body several times, Make the damping hole unobstructed, repair or replace the spring, reduce the flow of the remote control port, replace the oil and other components. The pressure setting of other components should not be similar to the pressure setting of the relief valve. 5. The noise of the elevator pipeline is usually caused by excessive dead bends or loose fixed sleeves in the hydraulic pipeline.


Agnel sur SeineHydraulic lifting table smallNurtured by quality



After 5000 hours of elevator operation, carry out medium maintenance on the mechanical and electrical systems.

Quality management.The above are the working principles of three common elevators, and there are also some forms of elevators that are not common, such as cylinder mounted elevators, curved arm elevators, car mounted elevators, etc. Their common feature is the hydraulic principle for operation,Agnel sur SeineHydraulic lifting platform, because the stability of the hydraulic system can bring better user experience and safer operation to the equipment, which has been favored by many users.

Firstly, rust prevention is necessary. Because the part of the hydraulic cylinder needs to extend out of the cylinder during operation, it will naturally be corroded by oxides and acidic gases. This requires us to apply an appropriate amount of grease to protect it from erosion as a weight component. If we change the oil, we must open the box and use it for a long time to prevent the hydraulic cylinder from being used for a long time. In the operation of hydraulic cylinders, the speed should be appropriate and should not exceed 2m/s to extend the service life of the hydraulic cylinder. In addition, in order to protect the mechanism and safety, it is very important to install buffer devices internally to protect the hydraulic cylinder. The greater the pressure of the protective hydraulic cylinder, the heavier the load, and the greater its pressure. A specialized product manufacturing enterprise that integrates research and development, as well as service. A long-term professional elevator manufacturer

. The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve, hydraulic control one-way valve, throttle valve, and explosion-proof electromagnetic directional valve. In order to ensure a smooth descent of heavy objects and safe and reliable braking, a balance valve and balance circuit are installed on the return oil circuit to maintain pressure and ensure that the descent speed is not affected by changes in heavy objects. The throttle valve regulates the flow rate and the lifting speed. To ensure safe and reliable braking and prevent accidents, a hydraulic one-way valve, also known as a hydraulic lock, is added to ensure safe self-locking when the hydraulic pipeline bursts. Install an overload sound alarm to distinguish between overload or equipment failure.

Agnel sur Seine.Electrical equipment or component failures. Hydraulic elevator manufacturers tell you that the main reasons for high noise generated by electric motors are: bent or severely worn motor rotors, or damaged bearings, which cause electric motors to sweep and produce noise; The cooling fan of the electric motor is damaged or not firmly fixed, producing high noise.

The smoothness of the gearbox, gearbox, external meshing gears, and hydraulic oil are all carried out according to the requirements in the smoothness table.

The hydraulic pump produces noise. When the hydraulic elevator rises, the hydraulic pump runs at high speed. If there is a problem with the gears or bearings of the hydraulic pump, which causes periodic changes in the hydraulic system pressure it will also cause resonance in the hydraulic system and generate noise.