Saint-Quentin Fixed hydraulic lifting platformIn the face of different forms, different maintenance measures must be taken.

announcer:hp530HP141750488 release time:2024-06-21 17:59:31

Pay attention to checking each steel wire rope for signs of broken wires and loose drums. If it exceeds the relevant rules, it is necessary to replace it immediately. The protection of steel wire ropes should strictly follow the rules of GB5144-85.

The characteristics of the platform include reliable hydraulic system, simple operation, large load-bearing capacity, and rear hinge support.

Saint-Quentin .Safety advantages: Hydraulic elevators are equipped with the safety devices of traditional traction elevators: overflow valve: it can prevent system pressure from being too high when going up; Emergency manual valve: In case of power failure, it can cause the car to emergency descend to the nearest floor position, causing the car to emergency descend to the nearest floor position, and causing the emergency in the car to descend to the nearest floor position; Pipeline rupture valve: When the hydraulic system's pipeline ruptures and the car stalls and descends it can automatically cut off the oil circuit and stop descending; Oil temperature protection of oil tanks: When the oil temperature of the oil tank exceeds the standard setting value, the oil temperature protection device sends a signal to stop the use of the elevator and wait for the oil temperature to decrease before starting the elevator. Long term promotion of downgrading manufacturers, 20 year old brand,Saint-Quentin Vehicle mounted hydraulic lifting platform,Saint-Quentin Manual hydraulic lifting platform, with price advantages and guaranteed quality!

The speed circuit is the circuit that switches the motion speed and speed of the actuator in the hydraulic system of the guide rail hydraulic lifting platform. Mainly including valves, pumps, high-speed circuits, and speed switching circuits.

.For hydraulic cylinders in hydraulic elevators, it is not practical to change their effective working area A (equivalent to displacement) to adjust the speed. Generally, the speed can only be adjusted by changing the flow rate. For variable displacement motors, speed regulation can change both the flow rate and the motor displacement.

The hydraulic elevator overflow valve can also generate high noise. When air is mixed in hydraulic oil, the overflow valve is stuck or severely worn, the spring of the overflow valve is fatigued and deformed resulting in unstable pressure regulation of the overflow valve, and the relief time of the overflow valve is too short, it is easy to cause the pilot valve performance of the overflow valve to be partially stable, causing air to vibrate inside the pilot valve and generate noise. So we need to regularly clean the overflow valve. When the overflow valve is damaged or severely worn, it should be replaced.

To consider its capacity, generally mobile equipment takes 2-3 times the high flow rate of pump Z, and fixed equipment takes 3-4 times.


Saint-Quentin Fixed hydraulic lifting platformIn the face of different forms different maintenance measures must be taken.



The classification of lifting platforms is as follows: they are divided into mobile lifting platforms, hydraulic lifting platforms, folding arm lifting platforms, and sleeve type lifting platforms according to their different modes of movement.

Lift and move horizontally with load to return to the loading position. For the transportation time of each item, such repeated cycles are called cycles.

Due to damage to the gear pump of the lifting cargo elevator equipment and no pressure lifting. Replace the gear pump.

Affordable price.Oil leakage is a common malfunction. Due to loose joints or damaged sealing rings, oil leakage may occur. Therefore, this fault can be solved by tightening the oil leakage joint or replacing the damaged sealing ring.

The main device does not engage. When this fault occurs, check whether the three-phase power supply is normal, whether the internal and external emergency stop button switches, the electric lock switch are turned on, whether the three-phase electrical phase sequence is correct, and whether the relay working indicator light is on.

When disassembling and adjusting the reverse organization of the equipment, attention should be paid to ensuring that the centerline of the reverse organization reducer is parallel to the centerline of the gear, and its meshing surface is not less than 70%. The meshing gap should be appropriate.


Saint-Quentin Fixed hydraulic lifting platformIn the face of different forms, different maintenance measures must be taken.



Ensure that there is a suitable power supply at the installation site, and separate maintenance of the distribution box is required. The distribution box should have a leakage switch, it should be suitable for the operating power.

reform.Check valve leakage: If the natural wear of the check valve exceeds the specified value after long-term use, it will cause leakage. Disassemble and clean the check valve, and replace it if necessary.

For example, setting anti fall and interaction can achieve good usage effects. This product is mainly used in various enterprise factories.

Remove the hydraulic oil tank filler cap, filter cover, inspection hole hydraulic oil pipe and other parts to avoid dust when removing the system oil pipe. Clean the disassembled parts before opening them. When disassembling the hydraulic oil tank filler cap,Saint-Quentin Hydraulic lifting platform, first remove the soil around the tank cap, loosen the tank cap, and remove any remaining debris from the joint (do not rinse with water to prevent water from seeping into the tank). After confirming cleaning, open the tank cap.

Saint-Quentin .A hydraulic elevator is a type of elevator equipment consisting of a walking mechanism, hydraulic mechanism, electric mechanism, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge.

If the circuit of the device is not disconnected or lowered, it is necessary to check the fuse for repair and replacement.

When the hydraulic oil is insufficient, the hydraulic pump will experience suction, causing air to enter the hydraulic oil and producing high noise.