HaHydraulic fixed lifting platformWhat are the precautions in the homework

announcer:hp530HP141750488 release time:2024-06-16 16:21:03

Stable and widely applicable cargo lifting equipment is mainly used for transporting goods between height differences in production lines; Material online and offline; Adjust the height of the workpiece during assembly; High altitude feeder feeding; Lifting of components during assembly of large equipment; Large machine material and cutting; The warehouse loading and unloading site is equipped with forklift and other transportation vehicles for rapid loading and unloading of goods.

Remove the hydraulic oil tank filler cap, filter cover, inspection hole, hydraulic oil pipe and other parts to avoid dust when removing the system oil pipe. Clean the disassembled parts before opening them. When disassembling the hydraulic oil tank filler cap, first remove the soil around the tank cap loosen the tank cap, and remove any remaining debris from the joint (do not rinse with water to prevent water from seeping into the tank). After confirming cleaning, it will cause leakage. Disassemble and clean the check valve please contact the manufacturer in a timely manner to avoid exceeding the warranty period.

Check valve leakage: If the natural wear of the check valve exceeds the specified value after long-term use, the hydraulic pump runs at high speed. If there is a problem with the gears or bearings of the hydraulic pump, which causes periodic changes in the hydraulic system pressure, it will also cause resonance in the hydraulic system and generate noise.

The hydraulic pump produces noise. When the hydraulic elevator rises, the hydraulic pump runs at high speed. If there is a problem with the gears or bearings of the hydraulic pump, which causes periodic changes in the hydraulic system pressure, the hydraulic cargo elevator wholesale should be promptly eliminated. Otherwise, it will affect the use of the guide rail hydraulic lifting platform. When refueling, the hydraulic oil should be filtered and filled, and the refueling tools should be reliable and clean. The hydraulic cargo elevator manufacturer should not remove the filter at the fuel tank filler to improve the refueling speed. Refueling personnel should use clean gloves and work clothes to prevent solid and fiber impurities from falling into the oil.


HaHydraulic fixed lifting platformWhat are the precautions in the homework



Each box, distribution box, etc. should be kept clean and promptly cleaned of dust on electrical equipment.

Cylinder diameter and hydraulic oil flow rate. The speed of the hydraulic lifting device is inversely proportional to the cross-sectional area of the cylinder rod and directly proportional to the flow rate of hydraulic oil. When the hydraulic elevator runs slowly, priority should be given to the hydraulic oil flow angle.

Protective device: In case of power or oil circuit failure, there should be a safety rope to prevent the workbench from falling out of control. (Allow controlled descent)

Safety and health.Reason: The lowering speed valve is out of adjustment. Cleaning method: If the lowering speed valve is adjusted, and if the adjustment is ineffective, replace it with a new valve.

When placing materials on the platform,HaScissor type hydraulic lifting platform, they should be placed in the middle of the platform as much as possible. The weight of the goods should be within the standard load range of the equipment, and the volume of the goods should not exceed the platform size of the equipment. Otherwise, materials and lifting platforms may be injured and dangerous accidents may occur. High priced and various specifications of elevator manufacturers provide timely supply, with high cost-effectiveness and have become the preferred brand for many wire products. Welcome to purchase!

When encountering signs of overheating in the electric motor, it is necessary to park the car in a timely manner, clean the problem, and continue running. The motor bearings should be smooth and outstanding.


HaHydraulic fixed lifting platformWhat are the precautions in the homework



There are many reasons for unstable workbench descent, such as overload, unstable support,HaHydraulic lifting platform truck, severe eccentric load, hydraulic oil impurities, etc. In response to the above reasons, it can be solved by reducing the load, adjusting the center of gravity of the load, and replacing hydraulic oil wholesale for hydraulic cargo elevators.

Safety and health.This paper briefly introduces some matters that should be paid attention to in the selection of oil tank for hydraulic elevators. The main functions of the hydraulic oil tank for elevators in the hydraulic systems of hydraulic machinery such as elevators and hydraulic elevators are oil storage, heat dissipation, separation of air contained in oil and elimination of foam.

The load of goods and the tonnage of goods transported at once also affect the lifting speed. The optimal value for transporting goods on a lifting platform is speed. If it is too heavy, it will affect the speed.

There are many reasons for unstable workbench descent, such as overload, unstable support, severe eccentric load, hydraulic oil impurities, etc. In response to the above reasons, it can be solved by reducing the load, adjusting the center of gravity of the load, and replacing hydraulic oil wholesale for hydraulic cargo elevators.

Ha.The development of elevators is at its peak, as many manufacturers have chosen more multi-story buildings to fully utilize the site, so they also need a device to facilitate the improvement of goods.

Users should arrange dedicated personnel to operate hydraulic elevators, and hang them on the

Reason: Cleaning method for internal leakage in the oil cylinder: Replace the sealing element of the oil cylinder. The lifting platform does not lower. Reason: The lowering valve is malfunctioning. Cleaning method: When pressing the lowering button,HaHydraulic lifting table, check whether the lowering valve is powered on. If there is no electricity, clean it as much as possible; If there is power, clear the malfunction of the lowering valve itself or replace the lowering valve. The sliding valve should be kept clean and.