HonoluluHydraulic lifting platform for loadingSelection of Value and Energy Conversion

announcer:hp530HP141750488 release time:2024-04-04 13:58:53

Therefore, in the hydraulic pipeline assembly line, it is necessary to avoid dead bends as much as possible and check the tightness of the sleeve in a timely manner.

If the circuit of the device is not disconnected or lowered, it is necessary to check the fuse for repair and replacement.

Honolulu.The lifting platform is mainly used for the up and down transportation of goods between various working floors, but it may slowly rise during use. When the equipment is working, it mainly uses hydraulic motors to drive hydraulic pumps. So what is the reason for the slow movement? Professional elevator manufacturer with large quantity and excellent quality at a reasonable price. Fire resistant, high temperature resistant, sturdy and durable safe and reliable

After 10000 hours of operation on the hydraulic lift, distribution box, etc. should be kept clean and promptly cleaned of dust on electrical equipment.

If the circuit of the device is not disconnected or lowered, it is necessary to check the fuse for repair and replacement.

The optional configurations of a fixed lifting platform include manual hydraulic power, movable flip plates that are easy to overlap with surrounding facilities, rolling or motorized roller tracks, safety contact bars to prevent foot rolling, organ type safety protective covers, hydraulic overturning workbenches, safety support rods to prevent the lifting platform from falling, stainless steel safety nets, electric or hydraulic lifting platform walking power systems, and universal ball countertops.


HonoluluHydraulic lifting platform for loadingSelection of Value and Energy Conversion



Motor not running: Check all components of the motor for damage and check if there are any problems with the circuit and wiring.

The manufacturer of hydraulic cargo elevators tells you the precautions for high-altitude operations.

Electrical equipment or component failures. Hydraulic elevator manufacturers tell you that the main reasons for high noise generated by electric motors are: bent or severely worn motor rotors, or damaged bearings,HonoluluVehicle mounted hydraulic lifting platform, which cause electric motors to sweep and produce noise; The cooling fan of the electric motor is damaged or not firmly fixed, resulting in high noise; The electric motor is not firmly fixed and can also cause vibration, producing high noise.

Executive standard.I believe many people want to know about the maintenance issues of guide rail hydraulic lifting platforms, as it is related to their service life. During use, frequently check the connection of each part. If loose, tighten it. When the body is under pressure, the tightness of the connecting bolts of the body should be checked (the pressure state that can be used). All connecting shafts should have split pins and hydraulic cargo elevators should be fully opened.

Ensure that there is a suitable power supply at the installation site, and separate maintenance of the distribution box is required. The distribution box should have a leakage switch, and the hydraulic cargo elevator construction site should be equipped with a fire extinguisher to prevent welding operations from causing fires. When selecting a leakage switch, it should be suitable for the operating power.

Therefore, in the hydraulic pipeline assembly line,HonoluluHydraulic lifting platform, it is necessary to avoid dead bends as much as possible and check the tightness of the sleeve in a timely manner.


HonoluluHydraulic lifting platform for loadingSelection of Value and Energy Conversion



The noise and oil level of the elevator oil cylinder are too low. From the air at the connection of the oil filter or joint to the oil, the coupling inside the oil cylinder is loose. The internal fault of the oil cylinder is that the installation of the oil cylinder motor is not concentric. From the motor, the air and oil at the moving shaft are blocked. The oil return pipe of the oil filter is loose, and the air or oil pipe is on the oil surface, Mixing air into the oil to eliminate: The concentricity should be adjusted to within 0.1MM. The coupling should be repaired or the oil pump should be replaced to increase the oil volume above 400mm in the oil filter and joint positions. The rotating shaft sealing ring should be replaced to clean the oil filter screen, filter the oil,Honolulu10 meter hydraulic lifting platform, lock the return oil pipeline, and extend the return oil pipeline below the oil level. If there is air mixed in the oil or the air in the hydraulic cylinder is not completely discharged, it will cause cavitation under high pressure and cause significant noise. At this point it is necessary to exhaust the air in a timely manner.

Inspection standard.Each brush should be kept clean on its surface, and the brush pressure should be adjusted to ensure that its area is not less than 50%.

The hydraulic elevator has no counterweight device, which improves the utilization rate of the well surface.

This paper briefly introduces some matters that should be paid attention to in the selection of oil tank for hydraulic elevators. The main functions of the hydraulic oil tank for elevators in the hydraulic systems of hydraulic machinery such as elevators and hydraulic elevators are oil storage, heat dissipation, separation of air contained in oil and elimination of foam.

Honolulu.Voltage too low: Measure the starter voltage, with an allowable fluctuation range of± 10%.

Check valve leakage: If the natural wear of the check valve exceeds the specified value after long-term use it will cause leakage. Disassemble and clean the check valve, and replace it if necessary.

When encountering signs of overheating in the electric motor, it is necessary to park the car in a timely manner, clean the problem, and continue running. The motor bearings should be smooth and outstanding.