TevesoHydraulic lifting platform supplierProblems and solutions

announcer:hp530HP141750488 release time:2024-03-23 09:03:17

There is noise inside the hydraulic cylinder. When replacing the hydraulic oil, there was air in the hydraulic cylinder due to an operational error. Under high pressure, it is easy to generate cavitation and high-frequency noise. When the rod is bent or replaced with a new seal, the new seal is too tight, which can also produce significant noise. If it is a problem of tight sealing, the noise can be reduced after running in for a period of time. If the rod is bent, it needs to be corrected. In addition, hydraulic pipelines should use hoses as much as possible, even when arranging pipelines, it can reduce vibration and noise, and the pipelines should avoid dead bends as much as possible.

Materials enter the production line at one end of the factory building, and the production process ends at the other end of the factory building with multiple separate platforms; This can greatly shorten the distance of material flow in the factory building.

Teveso.The safety belt should be inspected before use and a static load test should be conducted regularly (every 6 months). The load for the boarding bridge test is 225 kilograms, check for deformation, cracks, etc., and keep test records. Unqualified seat belts should be promptly dealt with.

The undercut length of the weld mm should not exceed 10% of the weld seam, and the depth should not exceed 0.4mm.

.The hydraulic elevator overflow valve can also generate high noise. When air is mixed in hydraulic oil, the overflow valve is stuck or severely worn, the spring of the overflow valve is fatigued and deformed, resulting in unstable pressure regulation of the overflow valve, and the relief time of the overflow valve is too short, it is easy to cause the pilot valve performance of the overflow valve to be partially stable, causing air to vibrate inside the pilot valve and generate noise. So we need to regularly clean the overflow valve. When the overflow valve is damaged or severely worn, it should be replaced.

A hydraulic elevator is a type of elevator equipment consisting of a walking mechanism, hydraulic mechanism, electric mechanism and support mechanism. The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve,TevesoElectric hydraulic lifting platform, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge.

New reference wiring diagram 2. Elevator leg noise. Mobile elevators should open the legs before operation. In this case, if the legs lack butter, the coupling inside the oil cylinder is loose. The internal fault of the oil cylinder is that the installation of the oil cylinder motor is not concentric. From the motor, the air and oil at the moving shaft are blocked. The oil return pipe of the oil filter is loose, and the air or oil pipe is on the oil surface, Mixing air into the oil to eliminate: The concentricity should be adjusted to within 0.1MM. The coupling should be repaired or the oil pump should be replaced to increase the oil volume above 400mm in the oil filter and joint positions. The rotating shaft sealing ring should be replaced to clean the oil filter screen, filter the oil, lock the return oil pipeline and extend the return oil pipeline below the oil level. If there is air mixed in the oil or the air in the hydraulic cylinder is not completely discharged, it is necessary to exhaust the air in a timely manner.

Based on the foundation plan, pay attention to alignment, leveling, and alignment to ensure the foundation level and various usage requirements. The access road for external construction elevators should be flat and have sufficient space for equipment parking.

. The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve, hydraulic control one-way valve, throttle valve, and explosion-proof electromagnetic directional valve. In order to ensure a smooth descent of heavy objects and safe and reliable braking, a balance valve and balance circuit are installed on the return oil circuit to maintain pressure and ensure that the descent speed is not affected by changes in heavy objects. The throttle valve regulates the flow rate and the lifting speed. To ensure safe and reliable braking and prevent accidents, a hydraulic one-way valve, also known as a hydraulic lock, is added to ensure safe self-locking when the hydraulic pipeline bursts. Install an overload sound alarm to distinguish between overload or equipment failure.

property right.For hydraulic cylinders in hydraulic elevators, it is not practical to change their effective working area A (equivalent to displacement) to adjust the speed. Generally, the speed can only be adjusted by changing the flow rate. For variable displacement motors, speed regulation can change both the flow rate and the motor displacement.

The smoothness of the gearbox, gearbox, and hydraulic oil are all carried out according to the requirements in the smoothness table.

Check valve leakage: If the natural wear of the check valve exceeds the specified value after long-term use, it will cause leakage. Disassemble and clean the check valve, and replace it if necessary.


TevesoHydraulic lifting platform supplierProblems and solutions



If the circuit of the device is not disconnected or lowered, it is necessary to check the fuse for repair and replacement.

Test method.The elevator itself has a simple structure and is easy to maintain, which has been favored by a large number of enterprises and individual customers. Hydraulic elevator is a multifunctional heavy loading and unloading mechanical equipment. The lifting system of hydraulic elevators is driven by hydraulic pressure, also known as hydraulic powered elevators.

The manufacturer of hydraulic cargo elevators tells you the reason for the instability of hydraulic lifting equipment. Hangzhou hydraulic cargo elevator equipment has always had good stability mainly used for heavy types of goods. However, during use, Hangzhou hydraulic cargo elevators may inevitably encounter some faults during the lifting process, such as very unstable conditions. What is the reason for the instability of the elevator? How to solve these problems?

The main device does not engage. When this fault occurs, check whether the three-phase power supply is normal, whether the internal and external emergency stop button switches the electric lock switch are turned on, whether the three-phase electrical phase sequence is correct, and whether the relay working indicator light is on.

Teveso.When encountering signs of overheating in the electric motor, it is necessary to park the car in a timely manner, clean the problem,TevesoPlatform hydraulic lifting,TevesoColumn hydraulic lifting platform, and continue running. The motor bearings should be smooth and outstanding.

Stable and widely applicable cargo lifting equipment is mainly used for transporting goods between height differences in production lines; Material online and offline; Adjust the height of the workpiece during assembly; High altitude feeder feeding; Lifting of components during assembly of large equipment; Large machine material and cutting; The warehouse loading and unloading site is equipped with forklift and other transportation vehicles for rapid loading and unloading of goods.

Each box, distribution box, etc. should be kept clean and promptly cleaned of dust on electrical equipment.