frequent inspections and maintenance should be carried out, which not only extends the service life of the hydraulic elevator, but also enables it to exert greater power during operation. Of course hydraulic elevators also have their own regular repair times and protection methods: regular protection (carried out per shift).

Motor not running: Check all components of the motor for damage and check if there are any problems with the circuit and wiring.

San Francisco.What are the benefits of hydraulic cargo elevators compared to traditional elevator cargo transportation?

Ensure that there is a suitable power supply at the installation site, and separate maintenance of the distribution box is required. The distribution box should have a leakage switch, and the hydraulic cargo elevator construction site should be equipped with a fire extinguisher to prevent welding operations from causing fires. When selecting a leakage switch, it should be suitable for the operating power.

.Voltage too low: Measure the starter voltage, with an allowable fluctuation range of± 10%.

Pre install equipment, maintain unobstructed access roads and sufficient parking space before pre installation. Some hydraulic cargo elevators require heavy lifting assistance for installation, some require equipment such as forklifts for installation,San FranciscoMobile hydraulic lifting platform, and some can be pre installed manually. When it is necessary to install with the assistance of a truck crane and a forklift, full consideration should be given to whether the on-site environment meets the working conditions of the truck crane.

Motor not running: Check all components of the motor for damage and check if there are any problems with the circuit and wiring.


San FranciscoSmall hydraulic lifting platformThe manufacturer teaches you how to improve work efficiency



If the circuit of the device is not disconnected or lowered, it is necessary to check the fuse for repair and replacement.

Cleaning and maintenance: When there is oil in the oil tank or when oil is refilled, it is necessary to ensure the cleanliness of the filter tank cover. Clean the oil and funnel or container before use. Never bring dirty things into the system, only clean oil.

The contact of the travel switch must be firmly opened and closed, and the contact crater should be polished in a timely manner.

Highly recommended.Electrical equipment or component failures. Hydraulic elevator manufacturers tell you that the main reasons for high noise generated by electric motors are: bent or severely worn motor rotors or damaged bearings, which cause electric motors to sweep and produce noise; The cooling fan of the electric motor is damaged or not firmly fixed, resulting in high noise; The electric motor is not firmly fixed and can also cause vibration, producing high noise.

After 10000 hours of operation on the hydraulic lift, major repairs will be carried out to the mechanical and electrical systems.

Pay attention to checking each steel wire rope for signs of broken wires and loose drums. If it exceeds the relevant rules,San FranciscoSmall hydraulic lifting and leveling, it is necessary to replace it immediately. The protection of steel wire ropes should strictly follow the rules of GB5144-85.


San FranciscoSmall hydraulic lifting platformThe manufacturer teaches you how to improve work efficiency



The installation personnel should confirm and count the equipment details,San FranciscoAutomatic hydraulic lifting platform, check if the tools are complete, and ensure the smooth progress of the installation process.

Total quality management.Hydraulic elevator manufacturers remind us that the basic principle of the hydraulic elevator speed control circuit is that the system often needs to adjust the movement speed of the hydraulic cylinder and hydraulic motor to adapt to the working cycle needs of the main machine. The speed of hydraulic cylinders and hydraulic motors depends on the displacement and input flow rate. It can be seen that changing the flow rate or displacement can affect the speed of the cylinder and motor.

Check valve leakage, oil pipe check valve leakage. The solution is to carefully check whether the one-way valve is functioning properly. If it is not normal, it is recommended to replace the one-way valve with a new one.

Volume speed control circuit: Speed control is achieved by adjusting the displacement of a variable pump or variable motor.

San Francisco.Surface paint quality: The paint should be smooth and flat, have good adhesion with metal, have uniform color, no bubbles, no cracks, and there should be no wrinkles, pits, paint leakage, and sagging.

Volume speed control circuit: Speed control is achieved by adjusting the displacement of a variable pump or variable motor.

The manufacturer of the hydraulic cargo elevator tells you the reason and cleaning method: Reason: Overload cleaning method: Reduce the load to clean. Reason: The return valve is not closed. Cleaning method: Tighten the return valve to clean. Reason: The one-way valve of the manual pump is stuck and the return valve is malfunctioning. Cleaning method: Unscrew the bolt at the valve port of the oil pump, conduct maintenance, cleaning, and replace the cleaning hydraulic oil to clean.