RaleighHydraulic small lifting platformOnline consultation

announcer:hp530HP141750488 release time:2024-02-03 15:56:05

What are the methods for reducing shaking on lifting platforms? Reducing the shaking of the lifting platform can reduce the psychological obstacles of the operators, ensure the smooth progress of the operation, and also greatly help improve safety. Warm reminder: safety, do not operate blindly. Lifts are widely used in many places, and their working principles vary. Today, we will analyze the working principles of elevators. The types of elevators are generally divided into the following: fixed elevators, This type of elevator uses hydraulic oil cylinders and pump stations to transmit power in the form of a scissor fork type. According to customer requirements, the length of the support rod for the scissor fork, the number of layers, the angle of the angle axis, and the expansion and contraction of the oil cylinder complete the lifting operation. Its advantages are large load-bearing capacity, stable lifting, and high safety.

The hydraulic elevator overflow valve can also generate high noise. When air is mixed in hydraulic oil, the overflow valve is stuck or severely worn, the spring of the overflow valve is fatigued and deformed, resulting in unstable pressure regulation of the overflow valve, and the relief time of the overflow valve is too short, it is easy to cause the pilot valve performance of the overflow valve to be partially stable, causing air to vibrate inside the pilot valve and generate noise. So we need to regularly clean the overflow valve. When the overflow valve is damaged or severely worn, it should be replaced.

Raleigh.It must be abnormal. To solve the problem,RaleighManual hydraulic lifting platform,RaleighPlatform hydraulic lifting, the first step is to identify the cause of the problem. Professional elevator manufacturers have strict testing quality assurance, and promotional activities are ongoing. Welcome to consult

Regularly check the operation of each mechanism for normal operation and noise. If any faults are found, the hydraulic cargo elevator wholesale should be promptly eliminated. Otherwise,RaleighHydraulic scissor type lifting platform, it will affect the use of the guide rail hydraulic lifting platform. When refueling, the hydraulic oil should be filtered and filled, and the refueling tools should be reliable and clean. The hydraulic cargo elevator manufacturer should not remove the filter at the fuel tank filler to improve the refueling speed. Refueling personnel should use clean gloves and work clothes to prevent solid and fiber impurities from falling into the oil.

.Ensure that there is a suitable power supply at the installation site, and separate maintenance of the distribution box is required. The distribution box should have a leakage switch, and the hydraulic cargo elevator construction site should be equipped with a fire extinguisher to prevent welding operations from causing fires. When selecting a leakage switch, it should be suitable for the operating power.

Set up warning lights around the guide rail type hydraulic cargo elevator equipment, and the warning lights will light up to warn operators when loading and unloading materials. Idle personnel are prohibited from entering the operating range.

If the circuit of the device is not disconnected or lowered, it is necessary to check the fuse for repair and replacement.


RaleighHydraulic small lifting platformOnline consultation



The use of cleaning oil and the brand used in the system

Hydraulic oil deteriorates or produces impurities. After long-term use of oil pressure, there may be impurities or deterioration in the oil. Sampling inspection should be carried out to see if there are solid particles discoloration, and odor. If necessary, the oil should be changed. There may be blockage in the hydraulic pipeline of the hydraulic cargo elevator. The hydraulic pipeline is also a very important part, and it is necessary to check whether the hydraulic pipeline is smooth. Focus on checking whether each type of hydraulic valve includes one-way globe valve, electromagnetic directional valve, proportional control valve, overflow valve, etc. If there are problems, the hydraulic valve should be cleaned or replaced in a timely manner.

After 1500 hours of elevator operation, perform minor repairs to the mechanical and electrical systems.

Inspection items.The hydraulic lifting platform often checks the connection status of each part, and if there is any looseness, it should be tightened. The connection bolts of the machine body should be checked for tightness when the elevator body is under pressure (the compression condition can be formed by rotating the arm). All connecting shafts need to have split pins and need to be fully opened.

Voltage too low: Measure the starter voltage, with an allowable fluctuation range of± 10%.

The hydraulic oil used in the system has the same brand, and the oil temperature is between 45~80 ℃. Use a large flow rate to remove impurities from the system as much as possible. The hydraulic system needs to be cleaned repeatedly three times or more, the system should be drained while the oil is hot. After cleaning, clean the filter and add new oil after using a new filter element.


RaleighHydraulic small lifting platformOnline consultation



Load bearing capacity: The lifting platform is placed on a horizontal support surface and the workbench is evenly loaded to 125% of the maximum load capacity. After lifting 100 times, attention should be paid to ensuring that the centerline of the reverse organization reducer is parallel to the centerline of the gear, and its meshing surface is not less than 70%. The meshing gap should be appropriate.

When loading and unloading goods at the dock, hydraulic cargo elevators are often used. What are the advantages and disadvantages of hydraulic cargo elevators compared to electric cargo elevators?

The manufacturer of hydraulic cargo elevators reminds the use of guide rail hydraulic lifting cargo elevators. Guide rail hydraulic lifting cargo elevators: Do not stand within the specified range, draw on the guide rail lifting platform, prohibit any idle personnel from entering the work area, ensure that the work area is free of clothing, the hydraulic elevator may experience problems with the hydraulic pump, motor, valve, which can easily cause vibration and generate significant noise.

After 1500 hours of elevator operation, perform minor repairs to the mechanical and electrical systems.

After 10000 hours of operation on the hydraulic lift, major repairs will be carried out to the mechanical and electrical systems.