BotulinumSmall hydraulic lifting and levelingIntroduction of the use opening situation

announcer:hp530HP141750488 release time:2024-02-02 15:14:18

Electrical equipment or component failures. Hydraulic elevator manufacturers tell you that the main reasons for high noise generated by electric motors are: bent or severely worn motor rotors, or damaged bearings, which cause electric motors to sweep and produce noise; The cooling fan of the electric motor is damaged or not firmly fixed, resulting in high noise; The electric motor is not firmly fixed and can also cause vibration, and there should be no jumping lifting phenomenon. All moving parts should be flexible when moving, and there should be no jamming devices. The lifting system of the elevator is divided into electric or manual hydraulic systems, and there should be no leakage at all components, pipelines, and joints.

Botulinum.The safety belt should be inspected before use and a static load test should be conducted regularly (every 6 months). The load for the boarding bridge test is 225 kilograms, and the test time is 5 minutes. After the test check for deformation, cracks, etc., and keep test records. Unqualified seat belts should be promptly dealt with.

Solution: Check if the performance of the legs is good, even if the butter is polished to increase its properties.

.Pre install equipment, maintain unobstructed access roads and sufficient parking space before pre installation. Some hydraulic cargo elevators require heavy lifting assistance for installation, some require equipment such as forklifts for installation, and some can be pre installed manually. When it is necessary to install with the assistance of a truck crane and a forklift,BotulinumPlatform hydraulic lifting, the greater the shaking. When using it at a working height of 10 meters, if possible, please use safety protection measures

Set up warning lights around the guide rail type hydraulic cargo elevator equipment, and the warning lights will light up to warn operators when loading and unloading materials. Idle personnel are prohibited from entering the operating range.


BotulinumSmall hydraulic lifting and levelingIntroduction of the use opening situation



The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects). The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve,BotulinumHousehold elevator, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve hydraulic control one-way valve, throttle valve, and explosion-proof electromagnetic directional valve. To ensure a smooth descent of heavy objects and safe and reliable braking, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure, so that the descent speed does not change due to heavy objects. The throttle valve regulates the flow rate and the ascending and descending speed. To ensure safe and reliable braking and prevent accidents, a hydraulic control one-way valve, also known as a hydraulic lock, is added to ensure safe self-locking in the event of an accidental rupture of the hydraulic pipeline. An overload sound control alarm has been installed to distinguish between overload or equipment failure.

A lifting platform is a lifting device that lifts people or goods to a certain height. When vertical conveying is carried out in logistics systems such as factories and automatic warehouses, various flat conveying equipment is often installed on the lifting platform as a connecting device for conveying lines at different heights. Usually driven by hydraulic pressure, it is called a hydraulic lifting platform. In addition to being used for transporting goods at different heights, it is widely used for high-altitude installation, maintenance, and other operations.

Solution: Check if the performance of the legs is good, and the warning lights will light up to warn operators when loading and unloading materials. Idle personnel are prohibited from entering the operating range.

Reason: The lowering valve is not tightly closed. Cleaning method: Check if the lowering valve is powered on. If there is no power supply, clear the malfunction of the lowering valve itself or replace the lowering valve. It is necessary to keep the valve of the lowering valve clean and flexible.

New reference wiring diagram 2. Elevator leg noise. Mobile elevators should open the legs before operation. In this case, if the legs lack butter, noise will be generated.


BotulinumSmall hydraulic lifting and levelingIntroduction of the use opening situation



Due to damage to the gear pump of the lifting cargo elevator equipment and no pressure lifting. Replace the gear pump.

Direct material.The lifting platform is placed on a horizontal support surface and the concentrated load of MAX load capacity is placed at any position 300mm away from the periphery of the workbench. After lifting 100 times, each load-bearing component must not have deformation or cracks.

Cylinder diameter and hydraulic oil flow rate. The speed of the hydraulic lifting device is inversely proportional to the cross-sectional area of the cylinder rod and directly proportional to the flow rate of hydraulic oil. When the hydraulic elevator runs slowly, priority should be given to the hydraulic oil flow angle.

The elevator itself has a simple structure and is easy to maintain, which has been favored by a large number of enterprises and individual customers. Hydraulic elevator is a multifunctional heavy loading and unloading mechanical equipment. The lifting system of hydraulic elevators is driven by hydraulic pressure, also known as hydraulic powered elevators.

Botulinum.The combined platform is often used in small workshops with small volume of goods. However,BotulinumElectric hydraulic fixed lifting platform, because this platform needs to complete two functions at the same time, it inevitably increases the distance of handling tools/vehicles in the workshop.

The lifting platform is placed on a horizontal support surface, and the concentrated load of MAX load capacity is placed at any position 300mm away from the periphery of the workbench. After lifting 100 times, each load-bearing component must not have deformation or cracks.

To consider its capacity, generally mobile equipment takes 2-3 times the high flow rate of pump Z, and fixed equipment takes 3-4 times.