NiljihasaHydraulic lifting cargo elevatorWear and failure

announcer:hp779HP136589660 release time:2024-01-10 10:20:47

it should be repaired by professional personnel. It is not allowed to modify the cargo elevator without permission.

Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that, remove the motor shaft key.

Niljihasa.How to solve the problem of oil pipe leakage due to the sinking of the elevator? It may be caused by damaged seals or cracks in the oil pipe, resulting in a pressure drop and inability to support the oil pipe to a large height.

Scissor type fixed lifting platform is a transportation and loading equipment that transports goods from one height to another. After operation, the platform is level with the ground without occupying ground space and affecting passage passage.

.What types of elevators are there? There are many types of such equipment,NiljihasaConstruction site personnel lifting cargo elevator, such as fixed lifting devices and vehicular lifting devices, depending on the form of movement. The so-called fixed lifting is generally installed in one place and fixed, and then lifting operations can be carried out. This type of lifting equipment is generally used more on the assembly line, and some large production lines need to lift the materials to a certain position when loading them, and then put them into production on the production line. A special lifting device needs to be fixed at a certain position on the production line.

The elevator is a kind of elevator equipment composed of a walking mechanism, a hydraulic mechanism an electric mechanism, and a support mechanism. The hydraulic oil forms a certain pressure by a vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, flameproof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve. This allows the hydraulic cylinder to move upward and lift heavy objects. The return oil from the upper end of the hydraulic cylinder returns to the tank through the flameproof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. Observe the reading value of the pressure gauge on the pressure gauge.

Large logistics warehousing equipment service company with guaranteed prices and guaranteed services, directly operated by the manufacturer. Because fixed elevators are mechanical equipment, the quality and performance of the product are good. Do not accept products from some manufacturers that do not meet the quality standards in order to avoid some safety hazards in use.


NiljihasaHydraulic lifting cargo elevatorWear and failure



The cleanliness of the hydraulic station is an important aspect of the elevator hydraulic station, so it should not be taken lightly. Moreover, from a professional perspective there are relevant rules and requirements. You should refer to the specification manual, so that you can have a correct understanding and know how to achieve better cleanliness.

Any kind of machine or equipment will undergo a series of inspections and debugging before leaving the factory, until all links are qualified. Take the mobile elevator for example, the same is true. Of course, during the internship, there will still be some questions about the elevator, but if there is no contact, just mastering some specific information can effectively handle these questions.

Precautions for elevator installation: Keep the access road of external construction elevators smooth and have sufficient space for parking equipment. When using a steam crane for auxiliary installation, full consideration should be given to whether the on-site environment meets the operating conditions of the steam crane.

Inspection environment.When a cargo elevator fails, it should be repaired by professional personnel. It is not allowed to modify the cargo elevator without permission.

Unscrew the screws on the dustproof hole on the outer side of the elevator flange, and tighten with the hexagon socket. After that, remove the motor shaft key.

Hydraulic pump station: domestic lifting platform dedicated pump station, mesh type, and iron plate sealed type.


NiljihasaHydraulic lifting cargo elevatorWear and failure



Carefully prepare a special construction plan for installation and construction, and provide safety technical disclosure to installation personnel.

reform.Guide rail elevator (also known as cargo elevator) is a non scissor fork type hydraulic lifting platform, mainly used in industrial buildings,NiljihasaIndoor cargo elevator, restaurants, warehouses, docks, workshops, and other places where vertical cargo handling is required between two or more floors. The low height is particularly suitable for sites that are not suitable for digging pits on site. What issues should we pay attention to in these places where elevators are used?

How to solve the problem of oil pipe leakage due to the sinking of the elevator? It may be caused by damaged seals or cracks in the oil pipe, resulting in a pressure drop and inability to support the oil pipe to a large height.

Outriggers: mechanical outriggers, hydraulic outriggers, ordinary hand cranking outriggers, and pull-out outriggers.

Niljihasa.Usage: Scissor fork type fixed lifting platforms are mostly used for goods transportation between height differences in production lines, loading and unloading materials, adjusting the working height during workpiece assembly, feeding materials to loading machines at high altitudes, lifting components during assembly of large equipment, matching storage and loading sites with forklift trucks and other transportation vehicles for rapid loading and unloading of goods, vehicle lifting,NiljihasaWarehouse elevator, fixed three-dimensional parking, and other places.

Different. (Specific bearing capacity and lifting height can be designed and customized according to user requirements)

Motor connection error. When the triangular connection motor is mistakenly connected into a star shape, the motor still operates with full load, and the current flowing through the stator winding exceeds the rated current, leading to the motor stopping itself. If the stopping time is slightly longer and the power supply is not cut off, the winding will not only be severely overheated, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch, the motor is mistakenly connected into two branches in parallel, both the windings and the iron core will overheat, and in severe cases, the windings will be burned.