After 5000 hours of operation of the elevator, repair the mechanical and electrical systems.

Check the hydraulic oil quality and level. When the lifting platform is raised to a high position, the hydraulic oil level should be 40-50 millimeters higher than the bottom of the oil tank. When the color of the hydraulic oil darkens,BrusselsHydraulic fixed lifting platform, the oil becomes sticky, or there are foreign objects such as gravel in the oil, it should be replaced immediately; When there is looseness in the connection part, tighten the pipe joint.

Brussels.It can be seen that the hydraulic lifting platform needs to carefully inspect the hydraulic and electrical systems before use, so as to facilitate its use.

The lifting stage can achieve the lifting of a double-layer tabletop. It can also be pieced into a stepped, multi scenic, and multi-level staircase as needed

.Maintenance time regulations for hydraulic elevators: After 1500 hours of daily maintenance of the elevator, repair the mechanical and electrical systems.

The current fixed hydraulic elevators are mainly enclosed or meshed lifting channels surrounded by buildings and light steel structures, and use hydraulic cylinders to lift the platform. Its main components are as follows: the lifting passage part: a closed or mesh frame surrounded by buildings or light steel structures, a fixed hydraulic lifting platform with steel guide rails installed on both sides of the internal driving part: it is equipped with hydraulic driving motors, oil pumps, safety valves, fixed hydraulic lifting platform speed control valves The small oil tank cylinder part of hydraulic components such as directional valves: composed of one or more cylinders of a lifting cylinder, a straight top platform, or a lifting shear fork frame, forming a door system. The closed or mesh platform door or door system consists of a steel structure, with manual and automatic doors. Generally, open platforms do not have doors. The electrical part is composed of power, signal, safety, lighting and other devices. The platform part is a steel structure platform that carries heavy objects, There are enclosed (i.e. cabin type) or open types, with guide rollers or guide shoes on both sides. The platform bottom can be connected to the lifting cylinder or lifting scissor type steel frame auxiliary parts, which are composed of hydraulic pipe fittings, pipelines, pressure gauges, and steel structure bases; Safety devices: safety valves, limit limits, door electromechanical interlocking, rupture valves, emergency switches, and electrical short circuit protection.

Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.


BrusselsHydraulic lifting platform safetyLand area



After working for 10000 hours, repair the mechanical and electrical systems of the elevator.

The above detailed introduction, I believe everyone has a comprehensive understanding and understanding of the use of hydraulic elevators, and these details cannot be ignored during the use process.

Regularly check all wires and cables for damage, and promptly wrap and replace the damaged parts.

Information recommendation.A complete lifting platform accessory can be selected and customized according to different places, venues, and environmental usage conditions. Meet the needs of different users. So why lifting platforms can be used and installed in so many industries and places is because they can achieve multi-purpose, demonstrate multifunctional, meet various different needs, and win market demand. In modern industrial transportation processes lifting platforms have begun to play an increasingly important role, whether in airports, docks, warehouses, workshops and other places that require rapid loading and unloading of goods, they have played a very practical value, It has also brought great contributions to the entire industry and even the entire economic development. However, long-term operation and use of these devices inevitably lead to wear and consumption and regular maintenance and upkeep are essential. Otherwise, both work efficiency and utilization rate will decrease,BrusselsPlatform lifting platform hydraulic, and at that time, the gains and losses will outweigh the losses.

Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective, whether there is a lack of hydraulic oil, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors, the maintenance of the guide rail type hydraulic lifting platform is also very simple, using oil cylinders and chain transmission, with very few moving components, so the maintenance workload is not very high. Moreover, this type of lifting cargo elevator has a very compact structure and uses fewer bearings, resulting in a longer service life.


BrusselsHydraulic lifting platform safetyLand area



Remove and disassemble the lowering valve, blow the valve core clean with compressed air,BrusselsHydraulic lifting platform, and tighten it if there is any looseness

When using hydraulic elevators, check the connections of each part during use and tighten them in a timely manner if there is any looseness. All connecting shafts require the use of split pins in order to ensure sufficient use and better utilization.

Remove and disassemble the lowering valve, blow the valve core clean with compressed air, and then reinstall it.

Brussels.Due to the fact that the power unit of the hydraulic lifting platform requires an oil source, its structure is relatively complex, and it also has a certain degree of pollution and impact on the environment. The speed of the moving device is relatively fast, making it difficult to meet the design requirements for speed. The structure of the electric rod is very simple, occupies small space, but does not have a price advantage. Therefore, a power source is used as the lifting power source, The DC motor is directly transmitted to other mechanical devices through a reducer for deceleration.

Safety protection components, in order to ensure safety production, it is essential to install a lifting platform for proper protection. The main protective accessories include safety belts, guardrails, protective covers platform stairs, etc.

Maintenance time regulations for hydraulic elevators: After 1500 hours of daily maintenance of the elevator, repair the mechanical and electrical systems.