OklahomaHydraulic lifting platformSeveral common production schemes and their principles

announcer:hp391HP142030639 release time:2024-05-31 09:56:00

Staying below high-altitude work sites is prohibited, and safety nets or other protective devices should be installed below the work site to avoid injury from falling objects.

The current fixed hydraulic elevators are mainly enclosed or meshed lifting channels surrounded by buildings and light steel structures, and use hydraulic cylinders to lift the platform. Its main components are as follows: the lifting passage part: a closed or mesh frame surrounded by buildings or light steel structures, a fixed hydraulic lifting platform with steel guide rails installed on both sides of the internal driving part: it is equipped with hydraulic driving motors, oil pumps, safety valves, fixed hydraulic lifting platform speed control valves The small oil tank cylinder part of hydraulic components such as directional valves: composed of one or more cylinders of a lifting cylinder, a straight top platform, forming a door system. The closed or mesh platform door or door system consists of a steel structure, with manual and automatic doors. Generally, open platforms do not have doors. The electrical part is composed of power, signal, safety, lighting,OklahomaHydraulic unloading platform, and other devices. The platform part is a steel structure platform that carries heavy objects,OklahomaHydraulic test platform, There are enclosed (i.e. cabin type) or open types, with guide rollers or guide shoes on both sides. The platform bottom can be connected to the lifting cylinder or lifting scissor type steel frame auxiliary parts, which are composed of hydraulic pipe fittings, pipelines, pressure gauges, and steel structure bases; Safety devices: safety valves, limit limits, door electromechanical interlocking, emergency switches, and electrical short circuit protection.

Oklahoma.When using a hydraulic lifting cargo elevator, it is necessary to have corresponding inspection routes. If the route malfunctions and the joint becomes loose, it is necessary to turn it on or off properly. In this case, there may be short lines or damaged components. Using a table for inspection is relatively better.

Then, the lifting platform platform platform that carries the load needs to be balanced, and no deviation of one side is allowed. The lifting of goods does not allow people to stand on both sides of the platform, and the lifting of goods should try to maintain a stable and uniform speed.

.If the elevator malfunctions,OklahomaChain hydraulic lifting platform, non electrical professionals are not allowed to disassemble and assemble electrical appliances at will to prevent accidental connection or electric shock!

Regardless of the type of lifting platform used, people are more concerned about the stability during use. Because the stability not only affects the actual use effect, but also has varying degrees of impact on the safety during use, it is necessary to pay appropriate attention. The same applies when using fixed loading and unloading platforms, but many times the stability of this type of platform can be trusted. The reason for saying this is because the manufacturer has taken this issue into account during production and manufacturing and the following aspects are taken to avoid this situation.

Remove trailing spaces, remove first and last interfering characters, remove blank lines, remove non paragraph blank lines punctuation correction: Leading space type: Number of spaces:


OklahomaHydraulic lifting platformSeveral common production schemes and their principles



The drive motor can stop the movement of the rack on the pillar.

When using hydraulic elevators, check the connections of each part during use and tighten them in a timely manner if there is any looseness. All connecting shafts require the use of split pins in order to ensure sufficient use and better utilization.

Troubleshooting: When the elevator power light is turned on, press the up button, the motor rotates, but the lifting platform does not rise. This may be due to the reversal of the motor after the three-phase power supply is connected, and a loading and unloading operation platform for enterprises to quickly and turnover products and goods. The height of the loading and unloading operation platform is fixed, but there is always a certain height difference or gap between the transportation vehicles and the loading and unloading platform due to the height of the carriage. Causing the forklift to be unable to enter and exit the transportation vehicle for direct loading and unloading of goods. Use the boarding bridge to provide reliable connections. Enable forklift trucks to quickly enter and exit transportation vehicles for loading and unloading operations.

The elevator has undergone strict testing before leaving the factory. If the pressure regulating valve is adjusted arbitrarily by non manufacturers, it may cause abnormal system operation. Non professionals should not adjust the pressure regulating valve arbitrarily!

The pressure lifting platform adopts a double four bar mechanism to achieve the lifting and flipping of the vehicle mounted cargo elevator platform, and a complex self-locking mechanism to achieve automatic opening and closing of the baffle. In order to reduce driving force, multiple sets of pulleys are used to achieve motion transmission and smooth movement on both sides of the lifting device. The hydraulic lifting platform adopts a hydraulic power unit transmission method, making the lifting more stable and the service life longer.


OklahomaHydraulic lifting platformSeveral common production schemes and their principles



Original software

Create brilliance.Maintenance time regulations for hydraulic elevators: After 1500 hours of daily maintenance of the elevator, it is necessary to regularly check all wires and cables used to ensure that there is no damage. When there is wrapping or damage, the parts should be replaced in a timely manner. I believe many people have encountered overheating in electric motors. In this case, it is necessary to stop the motor in a timely manner, and then troubleshoot the problem before continuing to use it. This way, the motor shaft can be used and the effect is good.

Copyright © 2006-2022 Yan-wei.Net.All Rights Reserved.

Oklahoma.After 5000 hours of operation of the elevator, repair the mechanical and electrical systems.

The seat belt needs to be inspected every six months, with a load of 225 kilograms. The test time is five minutes. After the test check whether the seat belt is broken or deformed, and keep records of the experiment. Any unqualified seat belts should be immediately stopped from use.