IzurdiStandard for power frequency withstand voltage test of dry type transformerThe construction follows the principle of trouble

announcer:hp122HP117294921 release time:2023-12-26 12:52:49

Oil immersed transformer operation

The flange surface is uneven, the tightening bolts are loose, and the installation and processing process is wrong, so that the bolts are not tightened well, resulting in oil leakage.

Izurdi.The domestic transformer market is slow

What is the wavelength of oil immersed transformer?

.Therefore, in the installation process of substation equipment, the lightning rod should be set according to the specific situation to prevent damage to the relay protection dry-type transformer caused by lightning. In addition, in the installation and use process of lightning rod,IzurdiPrice of recycled dry-type transformer, select reasonable types of lightning rod according to the operation situation to determine that they are in the same situation. In addition,IzurdiPower transformer M, during the installation of lightning rod,IzurdiWhat qualifications are required to install power transformers, please connect all routes as far as possible to prevent other faults.

Sound in case of phase failure

Some are tied with plastic tape, and some immediately press the two edges together, because the socket can not be pressed firmly during installation, and there is still oil leakage without sealing effect.


IzurdiStandard for power frequency withstand voltage test of dry type transformerThe construction follows the principle of trouble



Analysis of common faults of oil immersed transformer:

When the operating oil is mixed with different types of new oil or used for oil, in addition to the accurate measurement of the cold filter point of the mixed oil, it is also necessary to carry out high and low temperature test and sludge test, and observe the sludge accumulation. The accumulation cannot be accessed. The results of the operation of the mixing template are not that the original oil is very poor, so it can be managed and used in a mixed manner.

Some are tied with plastic tape, and some immediately press the two edges together, because the socket can not be pressed firmly during installation and there is still oil leakage without sealing effect.

Good reputation.For example, in the 1970s, the radio programs applied by every family in the countryside had a ground wire, and they were often wet with tap water. Protective grounding is to bury the copper plate of metal electrical conductor in the soil layer, and then lead a point of it out of the road with transmission line, which completes the grounding protection. The grounding wire specifies the grounding wire resistance ≤ 4Ω. Grounding protection is a safeguard measure adopted to avoid safety accidents when using household appliances, office and other electrical equipment.

Oil leakage of bolt or pipe external thread

Power transformer factory


IzurdiStandard for power frequency withstand voltage test of dry type transformerThe construction follows the principle of trouble



Different diversion methods, dry-type transformers mostly use silica gel waterproof casing, while oil transformers mostly use porcelain waterproof casing;

Safety production.Oil leakage of heat pipe radiator

Right, as & ldquo; Great Lars car & rdquo; After replacing one 255kva small transformer, the utilization rate is close, but the main parameters of the two transformers are evaluated as shown in Table 1. Table 1 evaluates the main parameters of the transformer: capacity (VA) iron loss (W) copper loss (W). Firstly, the output power is saved according to the customary calculation method (ignoring copper loss): the results show that the loss of large capacity transformer is lower than that of small capacity transformer, It actually consumes electromagnetic energy.

Connection group structure of dry-type transformer

Izurdi.In the case of using dry-type transformer, customers must master the method of wiring. If there are problems in wiring