lubbock Guide rail lifting cargo elevatorWord of mouth recommendation

announcer:hp779HP136589660 release time:2023-12-26 13:17:51

Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that, remove the motor shaft key.

Before connecting the motor to the elevator, the elevator manufacturer should first make the motor shaft keyway perpendicular to the tightening bolt. To ensure uniform stress, first screw on the mounting bolts at any diagonal position, and then tighten the four mounting bolts one by one. After that, tighten the tightening bolts. All tightening bolts shall be fixed with a torque wrench according to the indicated fixed torque data, and the use of elevators and lifting platforms shall be checked

lubbock .Make sure to add butter twice a month to the transmission assembly where the grease fitting is located. For parts where butter cannot be added, it is necessary to dredge the oil circuit or replace the grease fitting until butter can be added, otherwise it is prohibited to use the equipment.

Hydraulic pump station: domestic lifting platform dedicated pump station, Italian imported pump station with external protective devices: organ m type, mesh type, and iron plate sealed type.

.Motor connection error. When the triangular connection motor is mistakenly connected into a star shape, the motor still operates with full load, and the current flowing through the stator winding exceeds the rated current, leading to the motor stopping itself. If the stopping time is slightly longer and the power supply is not cut off,lubbock Chain guide rail cargo elevator lifting, the winding will not only be severely overheated, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch,lubbock Three ton cargo elevator, the motor is mistakenly connected into two branches in parallel, both the windings and the iron core will overheat, and in severe cases,lubbock Where is there a lift for goods, the windings will be burned.

Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes, with a scissors type mechanical mechanism, easy to maintain, and high bearing capacity. The lifting height is about 10 meters, and the load capacity is about 10 tons.

The hydraulic lifting platform can be divided into four wheeled mobile type, two wheeled traction type, vehicle modified type, vehicle type, auxiliary self-propelled type, and the lifting height varies from a meter to 1 meter.


lubbock Guide rail lifting cargo elevatorWord of mouth recommendation



Nowadays, small and medium-sized enterprises are products with the idea of good quality and preferential prices.

Replace with new oil and do not intermittently use the old oil, otherwise the moving parts in the system will accelerate wear.

Walking: assisted self-propelled, two wheel traction, self driving, and car modification.

Welcome calls .Characteristics of hydraulic elevators: Hydraulic lifting platform products are divided into curved arm type hydraulic lifting machines, mast type hydraulic lifts, and straight arm type hydraulic lifts according to their working modes. Hydraulic elevator is a replacement product of folding arm elevator (lifting platform) and scissor fork elevator (lifting platform). It can be widely used for the decoration and decoration of stations, docks, airports, hotels, posts and telecommunications, municipal gardens, garages, cleaning companies, public building facades, or the installation and maintenance of power systems, etc. This elevator has the advantages of light weight self-propelled walking, electric starting, self supporting legs, simple operation, large working area, and especially the ability to cross obstacles for aerial work.

Walking: assisted self-propelled, two wheel traction, self driving, and car modification.

Unscrew the screws on the dustproof hole on the outer side of the elevator flange, adjust the PCS system ring to align its side hole with the dustproof hole, and tighten with the hexagon socket. After that, remove the motor shaft key.


lubbock Guide rail lifting cargo elevatorWord of mouth recommendation



Usage: Scissor fork type fixed lifting platforms are mostly used for goods transportation between height differences in production lines, loading and unloading materials, adjusting the working height during workpiece assembly, feeding materials to loading machines at high altitudes, lifting components during assembly of large equipment matching storage and loading sites with forklift trucks and other transportation vehicles for rapid loading and unloading of goods, vehicle lifting, fixed three-dimensional parking, and other places.

Supply chain quality management.The brake operators of each mechanism on the equipment should regularly check and adjust the clearance of the brake shoe and brake wheel, ensuring flexibility and reliability. Long term improvement of the elevator factory, a 20 year old brand with competitive prices and guaranteed quality!

If the hydraulic valve is damaged, its effectiveness should be maintained. If it is damaged, it can be replaced in a timely manner.

The elevator is a kind of elevator equipment composed of a walking mechanism, a hydraulic mechanism an electric mechanism, and a support mechanism. The hydraulic oil forms a certain pressure by a vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, flameproof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve. This allows the hydraulic cylinder to move upward and lift heavy objects. The return oil from the upper end of the hydraulic cylinder returns to the tank through the flameproof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. Observe the reading value of the pressure gauge on the pressure gauge.

lubbock .Connect the motor to the elevator naturally. During connection, it must be ensured that the concentricity of the elevator output shaft and the motor input shaft is consistent and that the outer flanges of the two are parallel. Inconsistent centering can cause the motor shaft to break or the elevator gear to wear.

Several types: motor winding open circuit. When one phase of the motor winding is open circuit, or one of the parallel branches is open circuit, it will cause three-phase current imbalance and cause the motor to overheat.

Many people believe that the mechanical strength of the elevator itself is relatively high when using the elevator, so the installation method specified in the manual is not strictly followed during the installation process. However, this can lead to increased wear of parts and inflexibility in operation. In addition, use, when installing the elevator please be sure to carefully assemble and use it in strict accordance with the following installation and use related matters.