MinneapolisFixed lifting cargo elevatorClassification knowledge

announcer:hp779HP136589660 release time:2024-02-20 12:55:39

Safety performance: The lifting structure is made of high-strength manganese steel rectangular tubes, with a scissors type mechanical mechanism, easy to maintain, strong stability, and high bearing capacity. The lifting height is about 10 meters, and the load capacity is about 10 tons.

Systems: explosion-proof electronic control system, remote control system, PIC system.

Minneapolis.Main structure and purpose of guide rail type elevator: The mechanical part of guide rail type elevator mainly includes three parts: lifting device, track device, and belt changing device. The lifting device is mainly used to suspend the lifted person, which is the core part of the entire mechanism. The role of track device is mainly to provide movement trajectory making operation more smooth. The belt changing device is used to switch tracks when the elevator is about to pass through the door. The internal structure of the lifting device is mainly composed of a gear mechanism, a bracket, a worm gear, a guide mechanism, a lifting arm, upper and lower shells etc. Gear mechanism Gear mechanism mainly includes large and small gears, winding pulley, central shaft, and safety device composed of stop buckle and torsion spring.

It is good for aerial work vehicles not to cover their clothes and park outside. If it is windy and rainy, the clothes will repeatedly slap the car paint, especially if the vehicle blows sand on the clothes, causing many fine scratches on them, as the paint will become black over time. In addition, when the wind does not directly spray powder or clean the mechanism on the sand, it should be washed with water, and prevent the vacuum cleaner of the aerial work vehicle from scratching the sand particles on the paint surface.

.Secondly there should be no dirt on the friction surface. If there is any dirt, it should be washed off with gasoline or thinner; The reduction gearbox, gearbox, and other parts of the equipment, as well as the hydraulic oil, must be tested according to the requirements in the table; Correct maintenance of the hydraulic guide rail elevator: Regularly inspect the wire ropes at various parts for broken wires and looseness. If any such phenomenon is found, replace it in a timely manner. The maintenance of the wire ropes must be carried out in strict accordance with the specifications; Check the connection condition of each part according to the braking rules and regulations. If there is any looseness, tighten it in a timely manner. Check the tightness of the connecting bolts of the equipment when the body is under pressure. All connecting shafts should be equipped with cotter pins; Check whether the operation of each mechanism is normal, whether there are noises and faults according to regulations, and promptly remove all faults; When installing, disassembling, and adjusting the rotating mechanism of the equipment,MinneapolisFactory lift cargo elevator, it is important to note that the reducer and the gear center line should be parallel, and the meshing clearance should be appropriate; Regularly conduct a comprehensive inspection of the equipment to see if there is any damage to the wires and cables, and if there is overheating of the motor. Replace the motor in a timely manner and eliminate the fault before continuing operation; Ensure that the bearings, boxes, distribution boxes, and that the travel switch points of each safety device must be safe and reliable.

For guideway elevators installed outdoors, they are often exposed to rain and sunlight, so special attention should be paid to regular maintenance and inspection to avoid accidents.

The water cooling of hydraulic stations is generally tubular water cooling, and the type selection is based on the heat load to calculate the heat exchange area, while the air-cooled elevator is conducted using an air cooler, the type selection calculation is performed when the flow can be satisfied. Therefore, and there are significant differences. Long-term lifting and lowering of cargo elevator factory


MinneapolisFixed lifting cargo elevatorClassification knowledge



Many people believe that the mechanical strength of the elevator itself is relatively high when using the elevator, so the installation method specified in the manual is not strictly followed during the installation process. However, use it is necessary to pay attention to the installation precautions corresponding to the working environment and not be careless. Correct installation, and maintenance of the elevator are important steps to ensure the normal operation of mechanical equipment. Therefore, when installing the elevator, please be sure to carefully assemble and use it in strict accordance with the following installation and use related matters.

It is strictly prohibited to connect the motor of the lifting platform to the wrong power supply. It should be ensured that the voltage is 380v or 220v, and daily cleaning work should be carried out. Dust and debris on the motor should be cleaned in a timely manner.

Goods should be stacked well on the platform, and should not be tilted. When the goods elevator is lifting or lowering beyond the scope of the platform, no one should stand around to watch.

Process inspection.Does the cleanliness of the hydraulic station have relevant rules and requirements?

What types of elevators are there? There are many types of such equipment, such as fixed lifting devices and vehicular lifting devices, depending on the form of movement. The so-called fixed lifting is generally installed in one place and fixed, and then lifting operations can be carried out. This type of lifting equipment is generally used more on the assembly line, and some large production lines need to lift the materials to a certain position when loading them, and then put them into production on the production line. A special lifting device needs to be fixed at a certain position on the production line.

What is the new price for fixed elevators? Professional improvement of the quality assurance of the elevator factory. Preferential activities are ongoing, welcome new and old customers to consult


MinneapolisFixed lifting cargo elevatorClassification knowledge



'Using the elevator is not about maintaining and overhauling the equipment after it has failed. It is important to maintain the equipment in accordance with the correct maintenance and overhaul. First, do the preparatory work to eliminate all possible fault problems and accidents. I hope that today's summary of knowledge points by the editor can help everyone.'.

Inspection standard.What types of elevators are there? There are many types of such equipment, such as fixed lifting devices and vehicular lifting devices, depending on the form of movement. The so-called fixed lifting is generally installed in one place and fixed, and then lifting operations can be carried out. This type of lifting equipment is generally used more on the assembly line, and some large production lines need to lift the materials to a certain position when loading them, and then put them into production on the production line. A special lifting device needs to be fixed at a certain position on the production line.

Failure Analysis of Mobile Elevator

Incorrect connection of the elevator motor When a coil coil group, or one phase winding group is connected inversely, it can cause a serious imbalance in the three-phase current and cause the winding to overheat.

Minneapolis.Connect the motor to the elevator naturally. During connection, it must be ensured that the concentricity of the elevator output shaft and the motor input shaft is consistent, and that the outer flanges of the two are parallel. Inconsistent centering can cause the motor shaft to break or the elevator gear to wear.

Motor connection error. When the triangular connection motor is mistakenly connected into a star shape, the motor still operates with full load, and the current flowing through the stator winding exceeds the rated current, leading to the motor stopping itself. If the stopping time is slightly longer and the power supply is not cut off, the winding will not only be severely overheated, but also burned. When a star connected motor is mistakenly connected into a triangle, or when several coil groups are connected in series into a single branch, the motor is mistakenly connected into two branches in parallel,MinneapolisCustomized lifting cargo elevator, both the windings and the iron core will overheat, and in severe cases, the windings will be burned.

The water cooling of hydraulic stations is generally tubular water cooling, and the type selection is based on the heat load to calculate the heat exchange area, while the air-cooled elevator is conducted using an air cooler, and the heat exchange capacity is calculated based on the heat load. Then, the type selection calculation is performed when the flow can be satisfied. Therefore, the two types of cooling are different, and there are significant differences. Long-term lifting and lowering of cargo elevator factory