MaesterSmall electric elevator platformBrand strategy is the key to improving competitiveness

announcer:hp935HP175192871 release time:2024-01-20 11:46:13

The verticality of the guide rail frame should meet the requirements of the specifications.

Acceptance: Concrete strength grade C30, strength testing report.

Maester.The inner bearing of the roller in the device is in good condition, and a complete grease film surface is maintained between the curved surface of the roller and the main chord of the aluminum alloy electric elevator. A good grease film surface can reduce wear and noise

Setting requirements: The main connection methods between the wall bracket and the building include: connecting the wall bracket with the embedded parts on the wall; Fix with wall bolts; Embedded bolts; Welding with steel structures.

.Setting requirements: Before starting work every day and changing shifts, the driver of the construction electric elevator should inspect the construction electric elevator according to the requirements of the user manual and specifications, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test and the top layer is not affected. It can be customized according to the location and environment.


MaesterSmall electric elevator platformBrand strategy is the key to improving competitiveness



When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door and report any problems found to the user unit.

The counterweight guide rail should meet the specification requirements.

Civil engineering advantages: The pit depth of the guide rail type lifting platform is generally around 150-300mm, it worked normally.

Aluminum alloy lifting platforms can be divided into single column aluminum alloy, cargo elevator, double column aluminum alloy,Maester6-meter electric elevator, three column and four column aluminum alloy. Can be used in factories, automated warehouses, municipal facilities, docks, buildings,MaesterElectric guide rail elevator, and installations

When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

Installation requirements.Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator,Maester3 meter small electric elevator, the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.

After the electric elevator passes the inspection, the user unit shall organize the leasing unit, installation unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.

The verticality of the guide rail frame should meet the requirements of the specifications.


MaesterSmall electric elevator platformBrand strategy is the key to improving competitiveness



The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, otherwise protective measures shall be taken.

Safety and health.Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.

Installation position of upper limit switch: Under normal working conditions, the distance between the upper limit switch and the upper limit switch is 0.15m for SC type construction electric elevators, and 0.15m for SS type construction electric elevators (person)

Spiral electric lifting mechanism: With all the functions of a regular lifting platform, the main feature is that the equipment occupies a small foundation pit and has a large stroke. The equipment has a height of only 200-500mm and a travel distance of up to 14m. It is particularly suitable for buildings with stages built on two or more floors due to space constraints.

Maester.Setting requirements: For construction electric elevators with foundations installed on roof slabs, floors, or other lower suspended structures, the bearing capacity of the foundation support structure should be checked. Click here to download the construction technical information for free. Basic drainage facilities should be installed.

When the horizontal distance between the edge of the cage and the edge of the landing or between the cage and the landing door is greater than 150mm and there is no effective protection from other structures, the side protection device for the landing entrance should be equipped.

News Abstract: The development of the lifting platform industry will continue to grow in recent years! With the continuous development of electric lifting machinery for high-altitude operations in recent years, the products of electric lifting platform vehicles have been continuously improved, and various new technologies and materials have emerged, making the further development of lifting platform vehicles possible.