PingluLarge hydraulic lifting platformDevelopment in the chemical industry

announcer:hp530HP141750488 release time:2024-01-12 11:19:34

Electrical equipment or component failures. Hydraulic elevator manufacturers tell you that the main reasons for high noise generated by electric motors are: bent or severely worn motor rotors or damaged bearings, which cause electric motors to sweep and produce noise; The cooling fan of the electric motor is damaged or not firmly fixed, resulting in high noise; The electric motor is not firmly fixed and can also cause vibration, producing high noise.

The hydraulic oil used in the system has the same brand,PingluFixed hydraulic lifting platform, and the oil temperature is between 45~80 ℃. Use a large flow rate to remove impurities from the system as much as possible. The hydraulic system needs to be cleaned repeatedly three times or more and after each cleaning, clean the filter and add new oil after using a new filter element.

Pinglu.Ensure a good power supply at the installation site, install a separate distribution box, and when using the distribution box, the electrical leakage switch must meet the requirements for construction elevators. If the installed construction elevator is variable frequency,PingluHydraulic lifting platform, the leakage switch should be compatible with the frequency converter when selecting it.

Remove the hydraulic oil tank filler cap, filter cover, inspection hole, hydraulic oil pipe and other parts to avoid dust when removing the system oil pipe. Clean the disassembled parts before opening them. When disassembling the hydraulic oil tank filler cap, first remove the soil around the tank cap, loosen the tank cap, and remove any remaining debris from the joint (do not rinse with water to prevent water from seeping into the tank). After confirming cleaning, open the tank cap.

.Therefore, in the hydraulic pipeline assembly line, it is necessary to avoid dead bends as much as possible and check the tightness of the sleeve in a timely manner.

There is a phenomenon of self stopping when running up and down. Due to poor contact of the safety protection switch, it is easy for hydraulic cargo elevator manufacturers to cause this problem.

The development of elevators is at its peak, as many manufacturers have chosen more multi-story buildings to fully utilize the site, so they also need a device to facilitate the improvement of goods.


PingluLarge hydraulic lifting platformDevelopment in the chemical industry



Oil leakage is a common malfunction. Due to loose joints or damaged sealing rings, oil leakage may occur. Therefore, first connect the power supply and press the button to drive the motor of the hydraulic power unit to drive the gear pump. The hydraulic oil forms a certain pressure through the vane pump and passes through the oil filter; Explosion proof electromagnetic directional valve; Throttle valve; Hydraulic control one-way valve; The balance valve enters the lower end of the hydraulic cylinder, causing it to move upwards and lift heavy objects. The hydraulic cylinder moves downwards (i.e. the weight drops), the explosion-proof electromagnetic directional valve of the hydraulic oil enters the upper end of the hydraulic cylinder, and the return oil from the lower end of the hydraulic cylinder passes through the balance valve; Hydraulic control one-way valve; Throttle valve, explosion-proof electromagnetic directional valve.

Remember not to overload, formulate usage details and safety precautions for hydraulic elevators based on their own situation, and hang them on the

Oil leakage is a common malfunction. Due to loose joints or damaged sealing rings, oil leakage may occur. Therefore, this fault can be solved by tightening the oil leakage joint or replacing the damaged sealing ring.

To consider its capacity, generally mobile equipment takes 2-3 times the high flow rate of pump Z, and fixed equipment takes 3-4 times.


PingluLarge hydraulic lifting platformDevelopment in the chemical industry



The hydraulic pump produces noise. When the hydraulic elevator rises, the hydraulic pump runs at high speed. If there is a problem with the gears or bearings of the hydraulic pump,PingluStraight top hydraulic lifting platform, which causes periodic changes in the hydraulic system pressure, it will also cause resonance in the hydraulic system and generate noise.

Affordable price.Remove the hydraulic oil tank filler cap, filter cover, inspection hole, hydraulic oil pipe and other parts to avoid dust when removing the system oil pipe. Clean the disassembled parts before opening them. When disassembling the hydraulic oil tank filler cap, first remove the soil around the tank cap, loosen the tank cap, and remove any remaining debris from the joint (do not rinse with water to prevent water from seeping into the tank). After confirming cleaning, open the tank cap.

If working on a grid like platform, wooden boards should be laid to prevent tools and equipment from falling.

I believe many people want to know about the maintenance issues of guide rail hydraulic lifting platforms, as it is related to their service life. During use, frequently check the connection of each part. If loose, tighten it. When the body is under pressure, the tightness of the connecting bolts of the body should be checked (the pressure state that can be used). All connecting shafts should have split pins and hydraulic cargo elevators should be fully opened.

Pinglu.Regularly check all wires and cables for damage. It is necessary to wrap and replace the damaged parts in a timely manner.

To consider its capacity, generally mobile equipment takes 2-3 times the high flow rate of pump Z and fixed equipment takes 3-4 times.

The electromagnetic coil of the electromagnetic directional valve is not firmly fixed, and frequent separation and suction can also produce high noise.