Setting requirements: The anti loosening and anti loosening parts between the connecting parts should comply with the provisions of the user manual and should not be replaced by other objects. For connecting bolts with pre tightening requirements, a torque wrench or special tool should be used to accurately tighten the bolts to the specified torque value according to the specified tightening sequence. When installing standard section connecting bolts, it is advisable to place the screw at the bottom and the nut at the top.

The landing door should meet the requirements of the specifications and achieve standardization.

Wehrovo.Afterwards, it should be scrapped.

In order to meet the needs of contemporary audiences and achieve perfect effects, in addition to lighting and sound, stage machinery is particularly important on the stage. On the stage, there are suspension rods, suspension points lighting bridges, lighting suspension cages, and fire curtains. Under the stage, there are lifting platforms, car platforms turntables, or there are lifting platforms in the turntables. Various types of lifting platforms are equipped in professional opera houses and lifting orchestras. Some lifting platforms are equipped with turntables, dance theaters, drama theaters, meeting the needs of stage craft layout, meeting the needs of stage design and choreographers, creating special atmosphere and effects, and changing the stage form according to the needs of the performance.

.Setting requirements: Before starting work every day and changing shifts,WehrovoSmall mobile electric elevator, the driver of the construction electric elevator should inspect the construction electric elevator according to the requirements of the user manual and specifications, record the inspection results, and report any problems found to the user unit.

When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

Emergency manual valve: In case of power failure,Wehrovo1 ton electric elevator,WehrovoElectric elevators for elderly care, it can cause the car to descend to the nearest floor position and open the door


WehrovoElectric mobile hydraulic elevatorWhat problems are encountered in use



When the wall bracket cannot meet the requirements of the construction site, it should be designed and calculated separately.

The magnetic directional valve returns to the fuel tank. To ensure stable landing of heavy objects and safe and reliable braking, so that the landing speed does not change due to heavy objects. It is adjusted by the saving valve

The use of a lifting platform as a tool for storing performance blankets, soft scenery, etc. In some theaters, there is a soft scenery storage lifting platform located at an appropriate location on the stage for the storage of blankets, etc.

reform.The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.

When applying a normal force of 300N to any position on either side of the door using a rigid 5000mm2 square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding 30mm; After the test, it worked normally.

Speed limiter. To prevent the driving speed from exceeding the normal speed. A speedometer should be installed (not required for floors below or including the second floor), which is an individual mechanism that is integrated with a safety clamp; The entrance and exit of the passenger compartment should be equipped with safety doors. Public places, family dormitories, and


WehrovoElectric mobile hydraulic elevatorWhat problems are encountered in use



Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.

Promotion.After the electric elevator passes the inspection, the user unit shall organize the leasing unit, installation unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.

Folding arm electric elevators are mostly driven by hydraulic means, and the source of power for the hydraulic system is hydraulic oil. Only when the hydraulic oil quantity is sufficient and the oil quality is high, can the folding arm electric elevator provide greater torque output thereby improving work efficiency. So, how can we determine whether the newly added hydraulic oil quantity is sufficient? What is the hydraulic oil quantity standard?

The motor of the hydraulic guide rail lifting platform is set around the wellbore, occupying a relatively small area, improving the utilization rate of the wellbore area.

Wehrovo.Before installation, the installation unit should confirm that the foundation, foundation bearing capacity, embedded parts, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form, and concrete strength report.

Use floor doors and cage door devices on construction sites where conditions permit.

There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.