Burgess gradbachElectric tricycle hydraulic elevatorThe market is turbulent

announcer:hp935HP175192871 release time:2024-01-08 13:48:53

Setting requirements: The main connection methods between the wall bracket and the building include: connecting the wall bracket with the embedded parts on the wall; Fix with wall bolts; Embedded bolts; Welding with steel structures.

Stage equipment safety door. To prevent personnel from extending their heads, and feet out of the shaft and objects from falling into the vertical shaft. Its vertical position should be closed its cabin should be full of doors, and the height of the hoistway (hall door) should not be less than 8 meters; The electric door opening and closing switches should be removed from the vertical and passenger compartment doors. In order to prevent accidents caused by vertical, passenger car doors, and car roof doors not being closed.; Door interlocks should be installed on both the vertical and passenger compartment doors.

Burgess gradbach.The noise of aluminum alloy electric elevators during operation is relatively low. If the noise is high, it is abnormal. Therefore, it is necessary to do a good job in troubleshooting, find the cause in a timely manner, reduce noise pollution, and reduce dangerous accidents

When the distance between the outer edge of the construction electric elevator and the edge line of the external overhead power line cannot meet the requirements in the table above effective protective measures should be taken.

.The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

Pipeline rupture valve: When the hydraulic system pipeline ruptures and the car stalls and descends,Burgess gradbachAutomatic electric elevator,Burgess gradbachUsed electric elevator, it can automatically cut off the oil circuit and stop descent

The advantages and disadvantages of several commonly used electric lifting mechanisms are as follows: hydraulic electric lifting mechanisms: using hydraulic technology,Burgess gradbachElectric hydraulic elevator, smooth lifting and low noise.


Burgess gradbachElectric tricycle hydraulic elevatorThe market is turbulent



The verticality of the guide rail frame should meet the requirements of the specifications.

The magnetic directional valve returns to the fuel tank. To ensure stable landing of heavy objects and safe and reliable braking, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure, so that the landing speed does not change due to heavy objects. It is adjusted by the saving valve

Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

reform.When the distance between the outer edge of the construction electric elevator and the edge line of the external overhead power line cannot meet the requirements in the table above, effective protective measures should be taken.

Model Example: Hanging Cage Specification: LABSC200/200TD3200x1500 Type I: 2900~3600 Type II: 2900~3600 Type V: 1800~250044003800 Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x0.02 (kN).

The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator, with a size of 8 meters by 2 meters.


Burgess gradbachElectric tricycle hydraulic elevatorThe market is turbulent



Protective measures should comply with regulatory requirements.

wholesaler.Use floor doors and cage door devices on construction sites where conditions permit.

Limit switches should be triggered directly by the movement of the suspension cage or its related components.

From the perspective of the safety performance of the machinery itself, mechanical components may fall off or be damaged due to various factors. This problem depends on regular inspection and maintenance of the machinery

Burgess gradbach.To meet the needs of choreographers and choreographers in different plays, different heights of the lifting platform can be used to change the shape of the stage according to the requirements of the choreographers and choreographers, in order to adapt to the requirements of the plot for the scenery or venue, and save manpower and material resources for setting up. By using the tilting device of the lifting platform to form a tilted platform, a better highlighting effect can be achieved in various performances. According to the needs of the plot, special atmosphere and effects can be created. Even simple stage machinery often participates in performance activities, creating unexpected atmosphere and effects according to the needs of the plot. For example, using the low-speed descent of the lifting platform to represent a sunken ship in the sea, using the valves on the lifting platform and the sudden disappearance and appearance of actors on the lifting platform.

The net height of the landing door opening should not be less than 8m, and the difference between the net width and the outlet width of the cage door should not exceed 120mm. When the floor door is closed, except for the gap between the lower part of the door that should not exceed 35mm, the size of any through-hole and opening related to the distance between any door and adjacent moving parts, as well as the gap around the door or between parts, should comply with the provisions of Table 4 of 'Mechanical Safety - Safety Distance to Prevent Upper and Lower Limbs from Touching Dangerous Areas' GB23821-2009.

When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.