ColumbusZoomlion Electric ElevatorThe financial pressure is obvious

announcer:hp935HP175192871 release time:2024-01-08 09:12:01

Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator, the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.

Horizontal lead screw mechanical electricity

Columbus.Only after the operation of professional personnel can the suspension cage movement be restored.

Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.

.Once again, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective,ColumbusUsed electric elevator,ColumbusSmall electric automatic elevator, whether there is a lack of hydraulic oil, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors wiring, and oil cylinder once a week to avoid dust and debris affecting normal operation.

Civil engineering advantages: The pit depth of the guide rail type lifting platform is generally around 150-300mm, and the top layer is not affected. It can be customized according to the location and environment.

Speed limiter. To prevent the driving speed from exceeding the normal speed. A speedometer should be installed (not required for floors below or including the second floor), which is an individual mechanism that is integrated with a safety clamp; The entrance and exit of the passenger compartment should be equipped with safety doors. Public places, family dormitories, and


ColumbusZoomlion Electric ElevatorThe financial pressure is obvious



Drainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).

Attention should be paid to the occurrence of oil leakage on the aluminum alloy lifting platform to avoid secondary damage caused by a shortage of hydraulic oil. Overloading work is prohibited during use

Speed limit wire rope switch. When the speed limit wire rope trips or breaks. Make the electric elevator unable to start.

Finance Department.The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve, throttle valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve,Columbus2 meter electric lifting platform, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).

The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.

The advantages and disadvantages of several commonly used electric lifting mechanisms are as follows: hydraulic electric lifting mechanisms: using hydraulic technology, smooth lifting and low noise.


ColumbusZoomlion Electric ElevatorThe financial pressure is obvious



Flat screw mechanical electric lifting mechanism: The lifting platform of this structure has the advantages of small civil engineering coordination, shallow foundation pit required, large stroke, stable operation, low noise, and low cost. Adopting a horizontal screw drive and a scissor fork structure to achieve the lifting motion of the table, it can be stopped arbitrarily within the range of travel.

Direct labor.The end height of the guide rail frame above the high attachment point should comply with the provisions of the user manual.

The safety overtravel of limit switches and upper limit switches should comply with regulatory requirements.

Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.

Columbus.Double layer steel mesh: The diameter of the steel bars is 12mm, with a spacing of 200mm.

Before installation, the installation unit should confirm that the foundation, foundation bearing capacity, embedded parts, and foundation drainage measures of the installed construction electric elevator and auxiliary heavy equipment comply with the requirements of the special construction plan for the installation and dismantling of the construction electric elevator based on the construction electric elevator foundation acceptance form concealed engineering acceptance form, and concrete strength report.

Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.