CopenhagenSmall single column aluminum alloy elevatorIs there still room for development?

announcer:hp750HP120486450 release time:2024-01-01 14:31:19

. Before the maintenance of the hydraulic aluminum alloy elevator starts, the tools used must be counted. After the maintenance is completed,CopenhagenAluminum alloy double mast elevator, the tools should be classified and organized, and counted to prevent the tools used for maintenance from being left inside the equipment especially in the distribution box. When repairing the hydraulic system of the aluminum alloy elevator,CopenhagenElevating aluminum alloy platform, it is necessary to keep the maintenance site clean and dust-free. When repairing and fastening screws for aluminum alloy elevators, it is necessary to use the correct diagonal first. When tightening screws, use a torque wrench to prevent excessive damage to the screws. After the maintenance is completed and before the power on test, it is necessary to count the number of maintenance personnel to ensure that there is no one inside the aluminum alloy elevator. This is very necessary for the maintenance of large fixed hydraulic elevators. After counting the number of people, inspecting and repairing the equipment and the maintenance site, the power transmission test can only be carried out. After the maintenance of the aluminum alloy elevator is completed, the equipment maintenance record must be filled out. The maintenance record should include the equipment maintenance date, the personnel participating in the maintenance, the maintenance items, the brand, model and specification of the replaced parts, the effectiveness of the maintenance, and whether the equipment still has problems after the maintenance is completed.

The problem is that the power indicator light is on but there is&quo; in the electrical box when the up button is pressed; Clacking sound&rdquo, and use a multimeter to check if the electromagnetic valve can still be used. If it doesn't work, change it.

After working for 10000 hours, the mechanical and electrical systems of the elevator will be overhauled.

.It is strictly prohibited to run the engine for a long time in a closed garage. The exhaust gas of the aluminum alloy elevator engine contains carbon monoxide. This is a toxic gas that has been in low concentration for a long time

The surface of each part of the brush should be kept clean, and the brush pressure should be adjusted to ensure that its area is not less than 50%.

With the continuous increase of our productivity and the continuous improvement of our lives, the demand for aluminum alloy elevators is also increasing. The application of aluminum alloy elevators in every corner of our lives will bring us objective benefits.


CopenhagenSmall single column aluminum alloy elevatorIs there still room for development?



Next, let's talk about the maintenance and upkeep of mechanical equipment for aluminum alloy elevators: the brakes of each mechanism should be regularly inspected and adjusted to ensure flexibility and reliability.

Features of aluminum alloy elevator form:.

The garage door should be opened or the exhaust device should be opened. So that the exhaust gas can be stored in the garage at any time. Even if working outdoors. Also, rags, and removed parts should be checked for forgetting. After confirming that there are no errors. Only then can it be closed.

Is the power source noise abnormal during the lifting process of the aluminum alloy elevator?

After 5000 hours of operation of the elevator, carry out medium maintenance on the mechanical and electrical systems.


CopenhagenSmall single column aluminum alloy elevatorIs there still room for development?



Secondly, frequent voltage instability can directly burn out the power unit motor. The consequences of motor burning are very serious, which can lead to an instant decrease in pressure. If the equipment is not equipped with safety devices such as relief valves or explosion-proof valves, it can cause the lifting equipment to fall, leading to accidents. At the same time, replacing a new power unit also requires a certain cost.

Good reputation.The main components of the Hunter hydraulic fixed elevator are: 1. The shaft part is a closed or mesh frame enclosed by buildings or lightweight steel structures, with steel guide rails installed on both sides of the interior. 2. The driving part is equipped with a hydraulic drive motor, oil pump, and safety valve, A small oil tank for hydraulic components such as speed control valves and directional valves: 3. The oil cylinder part: It is composed of one or more oil cylinders of the lifting oil cylinder straight top platform or lifting shear fork frame: 4. The door system part: It is a closed or mesh platform door or landing door system composed of steel structure, with manual and automatic doors. Generally, open platforms do not have doors. 5. The electrical part: It includes power, signal, Composition of safety and lighting devices: 6 Platform parts: It is a steel structure platform that carries heavy objects, which can be closed (i.e. cabin type) or open, with guide rollers or guide shoes installed on both sides. The bottom of the platform can be connected to a lifting oil cylinder or a lifting shear fork shaped steel frame. When we use aluminum alloy elevators, maintain, and maintain them, which can not only extend the service life of the aluminum alloy elevator, Can make it work with greater power! For example the transmission part should have sufficient oil, and vulnerable parts must be regularly inspected, repaired, or replaced. Mechanical bolts, especially parts that frequently vibrate, such as slewing bearings and lifting arm connecting bolts should be checked for looseness. If there is looseness, it must be tightened or replaced immediately. Next,CopenhagenAluminum alloy mast type elevator, let's take a look at the regulations for the maintenance time of aluminum alloy elevators: daily maintenance (carried out per shift).

3 oil cylinder part: It is composed of one or more oil cylinders of the lifting oil cylinder straight top platform or the lifting shear fork frame.

The number of aluminum alloy elevators and the price of aluminum alloy elevators also depend on quantity and batch size. This factor is generally reflected in large quantities of customers. Generally, there may only be one or two units per person, and this price will not fluctuate significantly compared to the price provided by the manufacturer. For customers who have a long-term demand for 5 units and 10 units at a time, aluminum alloy elevator manufacturers will significantly reduce prices or increase rebates based on the quantity to maintain customers.

Copenhagen.Method: Check the length or diameter of the power supply lead. When the wire length is not more than 25 meters, the wire diameter should not be less than 1m ²; When the wire length is not greater than 50 meters, the wire diameter should not be less than 5m ². You can try fixing the plug directly to the socket without moving the cable.

Method: Check if the hydraulic oil in the mailbox is sufficient; Check if the oil filler cap of the fuel tank is excessively sealed, cover, etc. are displaced, whether the fixing screws are loose, and whether the ambient temperature of the equipment used meets the specified usage conditions. Air, check whether the motor, cover, etc. are displaced, whether the fixing screws are loose, and whether the ambient temperature of the equipment used meets the specified usage conditions.

After 5000 hours of operation of the elevator, carry out medium maintenance on the mechanical and electrical systems.