Valpalota3 meter high electric elevatorWhat is the basic performance problem

announcer:hp935HP175192871 release time:2023-12-31 11:55:02

different heights of the lifting platform can be used to change the shape of the stage according to the requirements of the choreographers and choreographers, in order to adapt to the requirements of the plot for the scenery or venue, and save manpower and material resources for setting up. By using the tilting device of the lifting platform to form a tilted platform, a better highlighting effect can be achieved in various performances. According to the needs of the plot, special atmosphere and effects can be created. Even simple stage machinery often participates in performance activities creating unexpected atmosphere and effects according to the needs of the plot. For example, using the low-speed descent of the lifting platform to represent a sunken ship in the sea using the valves on the lifting platform and the sudden disappearance and appearance of actors on the lifting platform.

Speed limit wire rope switch. When the speed limit wire rope trips or breaks. Make the electric elevator unable to start.

Valpalota.The top of the hanging cage is accessible; d) During installation/disassembly/maintenance/inspection of the device; e) Inside the hanging cage.

Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.

.Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.

Safety grounding device. In order to protect against electrical equipment. The metal casing of electrical equipment and the metal structure of electric elevators should be equipped with a safety grounding device. The grounding wire should operate multiple wires, and the neutral wire should not be arbitrarily held as a safety grounding wire. Its grounding resistance should not exceed 4 ohms; The power supply of the electric elevator can be cut off.

The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve,ValpalotaSmall electric mobile elevator,Valpalota8 meter electric elevator, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve,ValpalotaElectric mobile elevator, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).


Valpalota3 meter high electric elevatorWhat is the basic performance problem



Especially suitable for steel structured factories, suitable for both indoor and outdoor installation.

The suspension cage movement can only be resumed after operator operation.

Setting requirements: The verticality deviation of the installation of the guide rail frame of the construction electric elevator should comply with the requirements of the user manual and specifications, as specified in the above table.

Where can I find it?.Secondly, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, timely inspection of various functions is essential.

Safety grounding device. In order to protect against electrical equipment. The metal casing of electrical equipment and the metal structure of electric elevators should be equipped with a safety grounding device. The grounding wire should operate multiple wires, and the neutral wire should not be arbitrarily held as a safety grounding wire. Its grounding resistance should not exceed 4 ohms; The power supply of the electric elevator can be cut off.

Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.


Valpalota3 meter high electric elevatorWhat is the basic performance problem



The use of standard section connecting bolts should comply with the user manual and specification requirements.

Encyclopedic knowledge.The counterweight guide rail should meet the specification requirements.

Electric elevators should be regularly maintained and cleaned. During maintenance and cleaning, the bracket should be supported to prevent the electric elevator from overturning. Electrical and hydraulic systems should be maintained by professional personnel; When the battery level display is less than 40%

Especially suitable for steel structured factories, suitable for both indoor and outdoor installation.

Valpalota.Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

Protective measures should comply with regulatory requirements.

Use floor doors and cage door devices on construction sites where conditions permit.