GilbertZoomlion Electric ElevatorWhat are the uses and features

announcer:hp935HP175192871 release time:2023-12-22 10:19:11

Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.

The function of the lifting platform in a theater is roughly as follows: the main lifting platform arranged in the main performance area of the stage is mainly used to quickly change the scenery. Typically, with&quo; Product; In the music and dance theater stage arranged in a zigzag pattern,GilbertElectric elevator small, the lifting platform, side car platform,GilbertElectric passenger lift, and rear car turntable perform a rapid transformation of the entire or partial scene. This arrangement allows for rapid switching of three full sets.

Gilbert.Setting requirements: Construction electric elevators should be equipped with a down travel (limit) switch. The down travel (limit) switch should be able to automatically stop the cage running at rated speed before reaching the lower limit switch.

Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

.Then, the lifting platform platform platform that carries the load needs to be balanced, and no deviation of one side is allowed. The lifting of goods does not allow people to stand on both sides of the platform and the lifting of goods should try to maintain a stable and uniform speed.

Model Example: Hanging Cage Specification: LABSC200/200TD3200x1500 Type I: 2900~3600 Type II: 2900~3600 Type V: 1800~250044003800 Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x0.02 (kN).

Setting requirements: The installation and dismantling workers, electricians, and other operators of construction electric elevators should have special construction operations.


GilbertZoomlion Electric ElevatorWhat are the uses and features



During normal operation, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed 150mm.

The downward movement of the hydraulic cylinder (i.e. heavy object lowering). The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder passes through the balance valve, hydraulic control one-way valve, energy-saving valve, and explosion-proof electric valve

The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator, with a size of 8 meters by 2 meters.

Home page recommendation.The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance wall bracket spacing,GilbertThree phase electric elevator, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed 8 degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.

High lifting height, using side mounted oil cylinders, stable operation, noise free, easy maintenance, and longer service life.

The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.


GilbertZoomlion Electric ElevatorWhat are the uses and features



Setting requirements: Each landing entrance should be equipped with a landing door, which should cover the opening with its full width, and should not open towards the lifting passage.

Promise and keep promise.The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.

The magnetic directional valve returns to the fuel tank. To ensure stable landing of heavy objects and safe and reliable braking, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure, so that the landing speed does not change due to heavy objects. It is adjusted by the saving valve

Setting requirements: The landing door should be standardized and tooled.

Gilbert.Installation verticality deviation guide rail frame erection height, the verticality deviation of the guide rail frame should not exceed (5/1000) h.

Setting requirements: Before starting work every day and changing shifts, the driver of the construction electric elevator should inspect the construction electric elevator according to the requirements of the user manual and specifications, record the inspection results