BusiaSelf propelled hydraulic lifting platformWhat are the new highlights of the work

announcer:hp530HP141750488 release time:2023-12-17 12:27:40

Solution: Check if the performance of the legs is good, even if the butter is polished to increase its properties.

Each brush should be kept clean on its surface, and the brush pressure should be adjusted to ensure that its area is not less than 50%.

Busia.Operating cost advantage: Low failure rate: Due to the use of hydraulic systems and good methods, the failure rate of elevator operation can be reduced to a low level.

The installation personnel should have the qualification for installing hydraulic cargo elevators, carefully implement the special construction plan for installation and construction, and provide safety technical disclosure to the installation personnel for technical design.

.Therefore, the wholesale manufacturers of hydraulic elevators remind that there are three main ways to adjust the speed control circuit: throttling speed control circuit: quantitative pump oil supply, using flow valves to adjust the flow in and out of the actuator to achieve speed control; In the volume throttling speed control circuit, and the flow rate into the actuator is adjusted by the flow valve to adapt the flow rate of the variable pump to the regulated flow rate of the speed control valve.

When encountering signs of overheating in the electric motor, it is necessary to park the car in a timely manner, clean the problem and continue running. The motor bearings should be smooth and outstanding.

The elevator is evenly distributed at any position on the guide rail at 150% of the maximum load capacity, and the pilot valve and valve seat are matched without spring deformation or incorrect installation. The remote control port has excessive oil flow, low or high hydraulic oil viscosity, and resonance occurs with components in the circuit. Troubleshooting: Strengthen sealing, repeatedly adjust the pressure, exhaust and clean the valve body several times, Make the damping hole unobstructed, repair or replace the spring reduce the flow of the remote control port,BusiaHydraulic small lifting platform, replace the oil, and other components. The pressure setting of other components should not be similar to the pressure setting of the relief valve. 5. The noise of the elevator pipeline is usually caused by excessive dead bends or loose fixed sleeves in the hydraulic pipeline.

In addition, the convenience of the layout is also a very important issue. For example, in areas with large or high waves, there may be layout issues when using a lifting mechanism. At this point, in order to facilitate the arrangement and prevent the hydraulic cargo elevator cylinder from being eroded by waves, a lifting structure should be selected to determine the installation position of the oil shoulder,BusiaHydraulic lifting platform fixed type, as the lifting point of the bridge is not in a straight line during the lifting process. Therefore, during the lifting process of the cylinder, the connection between the two ends of the cylinder and other components must be hinged in the same square. In addition the installation of the hydraulic cargo elevator cylinder must also be determined through comparison and calculation, whether it is the tail lifting ear type, the middle pin shaft type, or the head pin shaft type. The main advantage is that the effective area of the cylinder is large, and the overall installation height is low. The disadvantage is that if the cylinder stroke is large, there may be stability issues with the cylinder, and the cylinder layout may be difficult. The main advantage of the hydraulic cargo elevator lifting mechanism is that it does not have a stable transmission installation frame for height measurement. Therefore, this form can be considered in places with large drops. The sudden deafness oil type on the head can reduce the installation height, but if it is too large, the oil cylinder will experience an increase in force due to the lifting height. Moreover, the higher the lifting height, the faster the increase in force which is not suitable for the use of the oil cylinder. Therefore, when it is too large the head pin type is not suitable. In order to comprehensively consider the height of the installation bracket and the force on the oil cylinder during the lifting process, an intermediate installation method can be considered, and the installation position can be set at an appropriate height according to calculations.

Regularly check the operation of each mechanism for normal operation and noise. If any faults are found, the hydraulic cargo elevator wholesale should be promptly eliminated. Otherwise, it will affect the use of the guide rail hydraulic lifting platform. When refueling, the hydraulic oil should be filtered and filled, and the refueling tools should be reliable and clean. The hydraulic cargo elevator manufacturer should not remove the filter at the fuel tank filler to improve the refueling speed. Refueling personnel should use clean gloves and work clothes to prevent solid and fiber impurities from falling into the oil.

quality standard.The optional configurations of a fixed lifting platform include manual hydraulic power, movable flip plates that are easy to overlap with surrounding facilities, rolling or motorized roller tracks, safety contact bars to prevent foot rolling, organ type safety protective covers, manual or motorized rotating workbenches, hydraulic overturning workbenches, safety support rods to prevent the lifting platform from falling, stainless steel safety nets, electric or hydraulic lifting platform walking power systems, and universal ball countertops.

The manufacturer of hydraulic cargo elevators will tell you about the knowledge of specialized lifting platforms for unloading.

Reason: Manual pump and gear pump have severe oil leakage. Cleaning method: Replace the oil pump sealing ring to clean it. Reason: Gear pump is damaged, and the contact crater should be polished in a timely manner.

In addition, the lifting mechanism also needs to be equipped with powerful support frames. Therefore, the selection of lifting mechanism or lifting mechanism for hydraulic freight elevators cannot be generalized, but should be based on the working conditions of the elevator.

When encountering signs of overheating in the electric motor, it is necessary to park the car in a timely manner, clean the problem, and continue running. The motor bearings should be smooth and outstanding.

Busia.Optional configuration of fixed lifting platform: The fixed lifting platform can be equipped with auxiliary devices according to usage requirements, such as the safety protection device of the fixed lifting platform; Electrical methods; Form of work platform; Power form, etc. The correct selection of various configurations maximizes the functionality of the lifting platform and achieves effective use.

There is air in front of the pilot valve of the elevator overflow valve noise overflow valve. The damping hole on the main valve core of the overflow valve is blocked by oil dirt, and the pilot valve and valve seat are matched without spring deformation or incorrect installation. The remote control port has excessive oil flow, low or high hydraulic oil viscosity, and resonance occurs with components in the circuit. Troubleshooting: Strengthen sealing, repeatedly adjust the pressure, exhaust and clean the valve body several times, Make the damping hole unobstructed, repair or replace the spring, reduce the flow of the remote control port,BusiaHydraulic straight top lifting platform, replace the oil, and other components. The pressure setting of other components should not be similar to the pressure setting of the relief valve. 5. The noise of the elevator pipeline is usually caused by excessive dead bends or loose fixed sleeves in the hydraulic pipeline.

The hydraulic elevator overflow valve can also generate high noise. When air is mixed in hydraulic oil, the overflow valve is stuck or severely worn, the spring of the overflow valve is fatigued and deformed, resulting in unstable pressure regulation of the overflow valve, it is easy to cause the pilot valve performance of the overflow valve to be partially stable, causing air to vibrate inside the pilot valve and generate noise. So we need to regularly clean the overflow valve. When the overflow valve is damaged or severely worn, it should be replaced.