Kessley22ov electric elevatorSeries function introduction

announcer:hp935HP175192871 release time:2023-11-15 09:12:19

routine inspections should be carried out according to regulations and inspection records should be filled out.

The connection method and angle between the wall bracket and the building structure should comply with the requirements of the user manual.

Kessley.Try to use this equipment in areas with wind force less than level five, and avoid using it when the wind force is too strong to avoid accidents.

Chain type electric lifting mechanism: With a good guiding mechanism, it can ensure that the equipment does not tilt during operation. Gear and rack electric lifting mechanism: precise transmission and high cost.

.The hydraulic oil enters the upper end of the hydraulic cylinder through the explosion-proof electromagnetic directional valve, and the return oil from the lower end of the hydraulic cylinder returns to the oil tank through the balance valve, hydraulic control one-way valve, throttle valve, and explosion-proof electromagnetic directional valve. To ensure a smooth descent of heavy objects and safe and reliable braking, a balance valve is installed on the return oil circuit to balance the circuit and maintain pressure,Kessley12 meter electric elevator, so that the descent speed does not change due to heavy objects. The throttle valve regulates the flow rate and the ascending and descending speed.

Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.

Once again,KessleyElectric self-propelled elevator, weekly inspections should be conducted to check whether the connecting screws at various parts of the lifting platform are tightened, whether the sealing rings are damaged or ineffective, and whether the oil cylinder is leaking. It is necessary to clean the lifting frame, scissors wiring, and oil cylinder once a week to avoid dust and debris affecting normal operation.


Kessley22ov electric elevatorSeries function introduction



Implementing multiple shifts of homework should fill in and submit records according to regulations.

Degrees, m/s.

Work is essential, and the main protective accessories include safety belts, guardrails, protective covers, platforms and stairs, etc.

Promise and keep promise.Setting requirements: Each landing entrance should be equipped with a landing door, which should cover the opening with its full width,KessleyFixed electric elevator, and should not open towards the lifting passage.

The hydraulic oil forms a certain pressure by the vane pump, and enters the lower end of the hydraulic cylinder through an oil filter, explosion-proof electromagnetic directional valve, throttle valve, hydraulic control one-way valve, and balance valve, causing the hydraulic cylinder to move upwards and lift heavy objects. The return oil at the upper end of the hydraulic cylinder returns to the oil tank through the explosion-proof electromagnetic directional valve, and its rated pressure overflow valve is adjusted. The pressure gauge observes the reading value on the pressure gauge. The downward movement of the hydraulic cylinder (i.e. lowering of heavy objects).

The use of standard section connecting bolts should comply with the user manual and specification requirements.


Kessley22ov electric elevatorSeries function introduction



The pump body adopts an integrated pump station all equipped with imported high-quality pump stations, which can also be selected according to customer requirements to meet customer ideal requirements.

superior quality.Setting requirements: The verticality deviation of the installation of the guide rail frame of the construction electric elevator should comply with the requirements of the user manual and specifications, as specified in the above table.

The use of fully autonomous electric elevators can create more benefits and ensure safety in all aspects.

When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

Kessley.Setting requirements: The layout and installation of all cables and wiring of electric elevators should be able to prevent mechanical damage.

Buffer. In order to increase the energy for the car to hit the top or sink to the bottom. Remove rubber or sponge from the buffer and cabin to increase their impact energy; Rope groove slipping and other accidents caused the car to suddenly fall, resulting in a safety clamp. To prevent breakage of the lifting wire rope. A safety clamp that can simultaneously cut off the power supply and stop the car from falling should be removed from the car. A car without safety tongs is not allowed to ride or carry people. If it is a simple electric elevator, there should be a safety device (such as a safety stop pin) to prevent people from suddenly falling when loading and unloading goods in the car; Electric elevators with three or more floors (including three floors) for passengers or passengers.

The L distance depends on the selected wall mount model.