OklahomaOutdoor electric lifting platformDesign advantages

announcer:hp935HP175192871 release time:2023-11-13 13:30:04

otherwise protective measures shall be taken.

.Mechanical devices controlled by cage movement should not be used to open or close the landing door.

Remind customers that there are still many areas to pay attention to when maintaining and maintaining the lifting platform. We also hope that customers and friends can pay more attention when using it to ensure the safety of personnel and property

Construction electric elevators outside the lightning protection range

The landing door should meet the requirements of the specifications and achieve standardization.

Oklahoma.Items and other miscellaneous items.

The distance between the electric hoist and overhead line in Electrical safety construction shall meet the specification requirements, and create greater benefits for the enterprise. What is the matching degree of electric elevators? Everyone has always been confused. In short the matching degree of electric elevators is how the height of the electric elevator can be combined with the operating height. Electric elevators are not used frequently, so we must make it clear based on the actual operating height and actual load capacity when using electric elevators. If the frequency is too high, We suggest considering purchasing a guide rail electric elevator or a scissor fork electric elevator. The scissor fork electric elevator can achieve a maximum load capacity of 100 tons, which effectively solves the problem of load capacity. If the frequency of use is too high and the height is relatively high, we recommend using a guide rail electric elevator. This type of electric elevator is not easy to malfunction under high-frequency operation,Oklahoma200 kg portable electric elevator, By solving the load capacity and frequency of use, and the rotary valve can reduce oil pipeline channels and optimize line settings.

Low level doors should be equipped with interlocking devices that can verify their closed and locked positions. The action of this interlocking device should be at the entrance of the cage. Simple use should not interfere with the operation of the interlocking device. The attached wall bracket should use matching standard products. When the wall bracket cannot meet the requirements of the construction site,OklahomaElectric elevator lifting 10 meters, it should be designed separately. The design of the wall bracket should meet the requirements of component stiffness, strength, stability, etc., and the production should meet the design requirements.


OklahomaOutdoor electric lifting platformDesign advantages



Construction electric elevators should be equipped with cable guide frames and comply with regulatory requirements.

Try to use this equipment in areas with wind force less than level five, and avoid using it when the wind force is too strong to avoid accidents.

Tank oil temperature protection: When the oil temperature in the tank exceeds the standard setting value, the oil temperature protection device sends a signal to suspend the use of the elevator. The elevator can only be started when the oil temperature drops

Sales Department.The quality of the standard section should comply with the product manual and specification requirements.

Setting requirements: The spacing of wall brackets along the vertical direction should comply with the provisions of the user manual.

Monthly maintenance and inspection of hydraulic lifting platform rollers, intermediate shafts and bearings, oil cylinder pin shafts and bearings, boom hinge shafts and bearings for wear. Add some oil to each part to extend the service life of the lifting platform bearings. The quality and level of hydraulic oil. The lifting platform should be raised throughout the entire process, and at this position, the hydraulic ground should be 40-50 millimeters higher than the bottom of the box. If the hydraulic oil becomes dark, sticky, or has foreign objects such as gravel, it should be replaced in a timely manner (32 # hydraulic oil). Annual maintenance and inspection of all hydraulic pipelines and joints of the lifting platform. The pipeline must not be damaged, blow out the plunger with compressed air,OklahomaFully self-propelled electric elevator, then install it and reinstall it. Drain and discard the hydraulic oil, tighten the joint, remove the oil filter, clean it with compressed air, and then return it to the oil tank and connect the pipeline.


OklahomaOutdoor electric lifting platformDesign advantages



The oil cylinder and sealing components are made of imported components to solve the problem of unstable oil pressure and oil leakage of components for customers.

investment.Civil engineering advantages: The pit depth of the guide rail type lifting platform is generally around 150-300mm, and the top layer is not affected. It can be customized according to the location and environment.

When a suspension cage with a rated load capacity acts on the buffer at a speed greater than the rated speed of 0.2m/s, the average deceleration of the suspension cage should not exceed 1g, and the time when the peak deceleration exceeds 5g should not exceed

Human improper operation is the main factor causing malfunctions in scissor type electric elevators. When stacking goods, electric elevators should stack the goods neatly, which is better than stacking them in the center of the cargo stacking area of the cargo elevator to avoid imbalance between the two ends of the stacking area. Eventually, during the operation of the electric elevator, it may cause the electric elevator to lose balance. After the goods are stacked completely, ropes should be used to lock the goods so that they are not afraid of the goods during the lifting process; Careless; Scattered down

Oklahoma.The use of standard section connecting bolts should comply with the user manual and specification requirements.

The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.

Emergency manual valve: In case of power failure, it can cause the car to descend to the nearest floor position and open the door