Berlin Brandenburg Airport Electric elevatorIndustry inspection explanation

announcer:hp935HP175192871 release time:2024-08-28 19:18:57

Berlin Brandenburg Airport Mobile small electric elevator,

Civil engineering advantages: The pit depth of the guide rail type lifting platform is generally around 150-300mm, the lifting platform is driven by electrical energy and lifted by the hydraulic system. During operation, it is necessary to avoid irregular operations. To ensure the normal and orderly operation of the lifting platform and achieve the ideal unloading level, timely inspection of various functions is essential.

Berlin Brandenburg Airport .When adding hydraulic oil, we can extend the oil cylinder to the high position for filling. When filling, the lifting platform should not exceed the high position, and then retract the oil cylinder back to the low position to check if the hydraulic oil level is lower than the low position, and maintain it between the two.

The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.

.Setting requirements: For construction electric elevators that operate in multiple shifts, the handover system should be implemented, and drivers should fill out the handover record form according to the standard requirements. The driver should conduct a pre shift inspection and confirm that there are no errors before starting the machine for operation.

Double layer steel mesh: The diameter of the steel bars is 12mm, with a spacing of 200mm.

The quality of the standard section should comply with the product manual and specification requirements.


Berlin Brandenburg Airport Electric elevatorIndustry inspection explanation



Then, the lifting platform platform platform that carries the load needs to be balanced, and no deviation of one side is allowed. The lifting of goods does not allow people to stand on both sides of the platform and the lifting of goods should try to maintain a stable and uniform speed.

In addition, when adding hydraulic oil, it is necessary to ensure the quality of the hydraulic oil, but also affects the working efficiency of folding arm electric elevators due to deterioration issues.

Before operating the construction electric elevator, routine inspections should be carried out according to regulations and inspection records should be filled out.

how much.In addition to ground protective fences,Berlin Brandenburg Airport Electric one ton elevator, low level doors can be used. Low level doors should meet the following requirements: the height of the door should be between 1m and 2m. And there should be at least protective railings,Berlin Brandenburg Airport Hand propelled electric elevator, a half height middle crossbar and a toe board at least 150mm above the ground.

After the electric elevator passes the inspection, the user unit shall organize the leasing unit, installation unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.

Model Example: Hanging Cage Specification: LABSC200/200TD3200x1500 Type I: 2900~3600 Type II: 2900~3600 Type V: 1800~250044003800 Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x0.02 (kN).


Berlin Brandenburg Airport Electric elevatorIndustry inspection explanation



For customers to use and operate the lifting platform for a long time, the editor briefly introduces how to maintain and repair the lifting platform: First of all, normal maintenance is mainly focused on prevention, especially if any damage or malfunction is detected and corrected or repaired in a timely manner. Careful inspection and maintenance at this time can save costs and avoid larger problems, resulting in costly repairs.

Affordable price.The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.

Platform.

High lifting height, using side mounted oil cylinders, stable operation, noise free, easy maintenance, and longer service life.

Berlin Brandenburg Airport .The pump body adopts an integrated pump station, all equipped with imported high-quality pump stations, which can also be selected according to customer requirements to meet customer ideal requirements.

The safety distance between the outer edge of the upper part of the landing door and the moving parts of the electric elevator during normal operation should not be less than 0.75m; If the rated speed is not greater than 0.7m/s, the safety distance can be 0.40m.

Protective measures should comply with regulatory requirements.