CangzhouElectric automatic elevatorWhere is the bottom of the fall

announcer:hp935HP175192871 release time:2024-08-19 16:17:50

The foundation production and acceptance of electric elevators for foundation construction should comply with the user manual and regulatory requirements.

When the foundation is set on the roof or floor structure, the bearing capacity of its supporting structure should be checked.

Cangzhou.The water cooling of hydraulic stations is generally tubular water cooling. The selection is based on the heat load to calculate the heat exchange area, while the air-cooled electric elevator uses an air cooler to calculate the heat exchange capacity based on the heat load. Then, the selection calculation is carried out under the condition of satisfying the flow rate. So, these two types of cooling are different and have significant differences.

Low power consumption: When the hydraulic guide rail lifting platform descends, it is driven by the pressure generated by its own weight, greatly saving energy and reducing consumption.

.Later, it should be repaired by professional personnel as soon as possible. After the malfunction occurs, it should not be used again to avoid accidents, personnel and property losses.

There is no need to set up a computer room above the shaft like an elevator, and the top floor height can be installed at least 2.5 meters.

Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.


CangzhouElectric automatic elevatorWhere is the bottom of the fall



Safety grounding device. In order to protect against electrical equipment. The metal casing of electrical equipment and the metal structure of electric elevators should be equipped with a safety grounding device. The grounding wire should operate multiple wires, and the neutral wire should not be arbitrarily held as a safety grounding wire. Its grounding resistance should not exceed 4 ohms; The power supply of the electric elevator can be cut off.

Aluminum alloy lifting platforms can be divided into single column aluminum alloy, cargo elevator, double column aluminum alloy, parking lots,CangzhouScissor fork electric lifting table, municipal facilities, docks, buildings, and installations

To meet the needs of stage craftsmanship and layout; Product; In the music and dance theater stage arranged in a zigzag pattern, auxiliary lifting platforms are often arranged in front, back, left, and right of the main stage lifting platform. The side and rear auxiliary lifting platforms are used for the smooth opening of the side platform and rear vehicle turntable, while the front auxiliary lifting platform is used to place the rear vehicle turntable near the platform entrance. The leveling lifting platform below the side platform and rear vehicle turntable can be used to level the platform after the side platform or rear vehicle turntable is driven out so that the entire platform does not have a height difference,Cangzhou6-meter electric elevator, ensuring the safety of the cast members.

Recommendation and consultation.Human improper operation is the main factor causing malfunctions in scissor type electric elevators. When stacking goods, electric elevators should stack the goods neatly, which is better than stacking them in the center of the cargo stacking area of the cargo elevator to avoid imbalance between the two ends of the stacking area. Eventually, during the operation of the electric elevator, it may cause the electric elevator to lose balance. After the goods are stacked completely ropes should be used to lock the goods,Cangzhou15 meter electric elevator, so that they are not afraid of the goods during the lifting process; Careless; Scattered down

After the electric elevator passes the inspection, the user unit shall organize the leasing unit, installation unit, and supervision unit to conduct acceptance. For the implementation of construction general contracting, the acceptance shall be organized by the construction general contracting unit. The acceptance form should be signed by the relevant responsible person.

Horizontal lead screw mechanical electricity


CangzhouElectric automatic elevatorWhere is the bottom of the fall



The safety bulletin board for construction electric elevators should be hung at the protective shed of the electric elevator, with a size of 8 meters by 2 meters.

Executive standard.Small safe operation distance: Circuit voltage (kV) of external power lines<11~1035~110220330~550 Small safe operation distance (m) 4681015 Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.

It is strictly prohibited to use travel limit switches as switches to stop operation.

Many theaters use a lifting platform as a vertical transportation tool for goods. The rear of the main stage or the end of the side stage in many theaters are equipped with a set container transportation lifting platform, which is used to vertically transport items from the ground to a designated location or even the stage plane. The lifting platform of the music pool is often used for transporting movable seats, etc.

Cangzhou.Setting requirements: The guide rail should be rigid and flexible components such as wire ropes or chains should not be used.

Mechanical devices controlled by cage movement should not be used to open or close the landing door.

The angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.